Electrical Data. ETAS ES650

Add to My manuals
47 Pages

advertisement

Electrical Data. ETAS ES650 | Manualzz

ETAS

5.9

5.9.1

5.9.2

5.9.3

Technical Data

Electrical Data

Power Supply

Operating voltage (reverse-polarity protected)

Power consumption (operation)

Power consumption (standby)

Fuse

7 to 29 V ±10 % (DC); load-dump pro tected max. 5.6 W typ. 50 mW

MINI, fast, 58 V, 3 A

Host Interface

Port

Protocol

IP address

Analog Voltage Inputs

Resolution

Sampling rate

Base-T Ethernet; 10 Mbps

TCP/IP dynamic via INCA

Input voltage ranges

Maximum input voltage

Hardware input filter

Digital low-pass filter

Input impedance

Maximum inaccuracy

Maximum temperature drift

16 bits, higher at slower sampling rates

0.5 to 2000 samples/sec, configurable for each channel

-10 V to +10 V (DC)

-60 V to +60 V (DC)

Input-to-input:

60 V DC / 30 V AC

Input-to-ground of voltage supply or housing:

60 V DC / 30 V AC

4th order low-pass,

Cutoff frequency 1 kHz, max. overshooting 3%

Digital Bessel 2nd order low-pass with adjustable cutoff frequency, can be dis abled

Automatic:

0.5 times sample rate

Manual: between 1 Hz and 1 kHz with an resolu tion of 1 Hz

> 15 M  || 1 nF in ±10 V measuring range;

2 M  || 1 nF im ±60 V measuring range

0.05% + 2 mV in ±10 V measuring range;

0,05% + 12 mV in ±60 V measuring range

10 ppm / K