![Electrical Data. ETAS ES650 | Manualzz Electrical Data. ETAS ES650 | Manualzz](http://s1.manualzz.com/store/data/068176823_1-1a67cf55866a93a27275e298eae09d44-360x466.png)
ETAS
5.9
5.9.1
5.9.2
5.9.3
Technical Data
Electrical Data
Power Supply
Operating voltage (reverse-polarity protected)
Power consumption (operation)
Power consumption (standby)
Fuse
7 to 29 V ±10 % (DC); load-dump pro tected max. 5.6 W typ. 50 mW
MINI, fast, 58 V, 3 A
Host Interface
Port
Protocol
IP address
Analog Voltage Inputs
Resolution
Sampling rate
Base-T Ethernet; 10 Mbps
TCP/IP dynamic via INCA
Input voltage ranges
Maximum input voltage
Hardware input filter
Digital low-pass filter
Input impedance
Maximum inaccuracy
Maximum temperature drift
16 bits, higher at slower sampling rates
0.5 to 2000 samples/sec, configurable for each channel
-10 V to +10 V (DC)
-60 V to +60 V (DC)
Input-to-input:
60 V DC / 30 V AC
Input-to-ground of voltage supply or housing:
60 V DC / 30 V AC
4th order low-pass,
Cutoff frequency 1 kHz, max. overshooting 3%
Digital Bessel 2nd order low-pass with adjustable cutoff frequency, can be dis abled
Automatic:
0.5 times sample rate
Manual: between 1 Hz and 1 kHz with an resolu tion of 1 Hz
> 15 M || 1 nF in ±10 V measuring range;
2 M || 1 nF im ±60 V measuring range
0.05% + 2 mV in ±10 V measuring range;
0,05% + 12 mV in ±60 V measuring range
10 ppm / K
ES650.1 - User Guide 32
advertisement
Related manuals
advertisement
Table of contents
- 5 About this Document
- 5 Classification of Safety Messages
- 5 Presentation of Instructions
- 6 Typographical Conventions
- 6 Presentation of Supporting Information
- 6 Scope of supply
- 6 Additional information
- 7 Basic safety notices
- 7 General safety information
- 7 Requirements for users and duties for operators
- 7 Intended use
- 12 Hardware Description
- 12 ES600 Measurement Modules
- 13 ES650.1 A/D and Thermo Module
- 13 Overview
- 14 Features
- 15 Package Contents
- 15 Housing
- 16 Ports and Indicators
- 16 Front Side
- 17 Indicators
- 18 Rear Side
- 19 Maximum Input and Common-Mode Voltages
- 20 Measurement Accuracy
- 22 Getting Started
- 22 Installation and blocking
- 22 General installation recommendations
- 22 Fastening the module onto a carrier system
- 23 Connecting several modules mechanically
- 24 Cabling
- 26 Configuration
- 26 Calibration
- 27 Technical Data
- 27 General Data
- 27 Product labeling
- 28 Fulfilled Standards and Norms
- 28 Environmental Conditions
- 28 Maintenance the Product
- 28 Cleaning the product
- 28 Mechanical Data
- 29 RoHS Conformity
- 29 CE conformity
- 29 UKCA conformity
- 29 KCC conformity
- 29 Taking the Product Back and Recycling
- 30 Use of Open Source software
- 30 System Requirements
- 30 Hardware
- 31 Software
- 32 Electrical Data
- 32 Power Supply
- 32 Host Interface
- 32 Analog Voltage Inputs
- 33 Thermocouple Inputs
- 34 Pin Assignment
- 34 Analog Inputs
- 34 Thermocouple Inputs
- 35 Ethernet Interface, Power Supply
- 35 External Display
- 36 Cables and Accessories
- 36 Measuring Cable
- 36 Measuring Cable with Banana Plugs
- 36 Measuring Cable with BNC Plugs
- 36 Adapter Cable with BNC Plugs
- 37 Ethernet Cable/Power Supply Cable
- 37 Y-Cable (ES650.1 in Stand-alone Mode)
- 38 Connecting Cables to the ES
- 40 Ordering Information
- 40 Accessories
- 41 Calibration
- 43 Configuration
- 44 Contact Information
- 45 Figures
- 46 Index