Wiring diagram

* The wiring diagram below shows a fully equipped model.

L1 L2 L3 N

Terminals for extension RS1

Wiring length

2 m or less

RS2

Control power supply

513 P1

+

P2 97 C1

+

A1

+

See the figure below for wiring.

+ +

D2 D1 413 U1

+

Electronic trip relay

(ETR)

Reset circuit Power supply circuit

Alarm contacts

(Power supply type P3 ~ P5 only)

SHT CC

UVT

M

Breaker

Main circuit

N1 N2 Z1 Z2 P4

(

M8 screw

)

NCT ※ ZCT ※

※ Voltage forbid to be applied.

FG

Dielectric test forbidden

574 564 554 544 534 524 98 C2 A2 DT2 DT1 414 U2

Shorting bar

Push button for tripping

Wiring length

2 m or less

Electronic trip relay

Control power supply circuit/ alarm contact

OCR alarm

Electric operation circuit

E-32

Terminal description

13 14 ~ 53 54

11

U1

12

U2

~ 51 52

413 414

D1 D2

DT1 DT2

A1

C1

97

P1

P4

RS1 RS2

513 524

513 534

513 544

513 554

513 564

513 574

Z1 Z2

N1 N2

A2

C2

98

P2

Extension terminals

Auxiliary switch "a"

Auxiliary switch "b"

Motor charging

Charged signal (Normal open)

Voltage Input terminal of UVT

Trip terminal of UVT (Remote trip)

Closing coil

Shunt trip

OCR alarm

Power supply for ETR

FG of power supply (FG:Frame Ground)

Alarm reset (Trip cause LED, alarm contact)

Alarm contact for LTD Trip

Alarm contact for STD or INST Trips

Alarm contact for Ground fault, Earth leakage trips or 2nd Pre-alarm contact

Pre-alarm contact

Temperature alarm contact

Error alarm contact

For external ZCT

For Neutral CT

For external display DP2

For Interface unit

For VT unit

Fig. 32

CC

M

UVT

AX

AL

CLS

SBC

CL

Accessory Symbols

SHT Shunt tripping device

Closing coil

Motor(Motor charging device)

UVT coil

Auxiliary switch

OCR alarm switch

Charge limit switch

Shorting b-contact

Cell switch

Internal wiring

External wiring (user's wiring)

Control circuit connecter (drawout type)

51

+

41

+

31

+

21

+

11

+

53

+

43

+

33

+

23

+

13

+

341

+

331

+

321

+

311

+

Cell switch

52 42 32 22 12 54 44 34 24 14 344 342 334 332 324 322 314 312

Auxiliary switch (“b” contact) Auxiliary switch (“a” contact)

UVT controller voltage application

For 100-120 V AC

For 200-240 V AC

DC ratings

Apply voltage

D2 D1

For 380-460 V AC

Apply voltage

IN2 IN1

External unit

OUT4 OUT3

D2 D1

Control circuit terminal block

Applicable crimp terminal

A A

A = 7.2 mm or less

Applicable crimp-type terminals for M3.5 screws with an outer diameter of 7.2 mm or less.

(Wire size 1.25 mm 2 to 2.0 mm 2 )

Cell switch

˜

˜

For the drawout type, the cables should have the length which allow the control circuit terminal block to be moved to the left or right by 5mm.

When a coil load is connected in the same control circuit as the ETR, surge absorbers are required to absorb the surge voltage.

˜ OCR alarm (AL)

The contact output of the OCR alarm (Standard type AL) is the one-pulse output and the output time is 30~50ms.

For this reason, this output needs self-holding circuit.

˜ For Power supply type P3 and P4, the high sensitive relay used in contact output may cause the chattering noise (wrong output of 1ms level) during ON and OFF operation, depending on the

Panel placing condition. When it is used in the quick responsive sequence, the filter circuit of a few milli-second (ms) should be provided or the double reading sampling should be implemented.

˜

˜

Closing coil (CC)

As CC is one-pulse driven, it is not necessary to insert AXb for burning prevention purposes.

Inserting AXb will cause anti-pumping function to be ineffective.

Under voltage trip device (UVT)

Use the switch that can open and close 150V DC, 0.5A for remote trip.

Remote trip terminal has short bar at shipment, so remove it before using this function.

Disconnect the voltage input wires during dielectric testing of main circuit.

˜ Since some terminals are polarized, the wiring should be done correctly as the polarity shown in the wiring diagram when the control voltage is DC. Auxiliary switch (AX) Standard type has no polarity.

˜ Alarm reset (Terminal: RS1 and RS2 ) is available only for Power supply type P3, P4 and P5.

For Power supply type P1 and P2, it can not be reset from the Control circuit terminal block ( RS1 and RS2 ).

˜ 513 574 P3 P4

˜ FG (Terminal: P4 ) is the protective earth for power supply (Terminal: P1 , P2 ).

It is recommended to use this terminal to reduce surge (M8 screw required).

˜ Shorting b-contact (SBC)

SBC can be provided for all AX b contacts. At the time of shipment from factory, SBC is already connected to control circuit terminal block. Only one more crimp terminal can be added on contact, overlapping with SBC’s contact on Terminal: 11 ~ 51 .

* The wiring diagram below shows a fully equipped model.

L1 L2 L3 N

Terminals for extension RS1

Wiring length

2 m or less

RS2

Control power supply

513 P1

+

P2 97 C1

+

A1

+

See the figure below for wiring.

+ +

D2 D1 413 U1

+

Electronic trip relay

(ETR)

Reset circuit Power supply circuit

Alarm contacts

(Power supply type P3 ~ P5 only)

SHT CC

UVT

M

Breaker

Main circuit

N1 N2 Z1 Z2 P4

(

M8 screw

)

NCT ※ ZCT ※

※ Voltage forbid to be applied.

FG

Dielectric test forbidden

574 564 554 544 534 524 98 C2 A2 DT2 DT1 414 U2

Shorting bar

Push button for tripping

Wiring length

2 m or less

Electronic trip relay

Control power supply circuit/ alarm contact

OCR alarm

Electric operation circuit

Terminal description

13 14 ~ 53 54

11

U1

12

U2

~ 51 52

413 414

D1 D2

DT1 DT2

A1

C1

97

P1

P4

RS1 RS2

513 524

513 534

513 544

513 554

513 564

513 574

Z1 Z2

N1 N2

A2

C2

98

P2

Extension terminals

Auxiliary switch "a"

Auxiliary switch "b"

Motor charging

Charged signal (Normal open)

Voltage Input terminal of UVT

Trip terminal of UVT (Remote trip)

Closing coil

Shunt trip

OCR alarm

Power supply for ETR

FG of power supply (FG:Frame Ground)

Alarm reset (Trip cause LED, alarm contact)

Alarm contact for LTD Trip

Alarm contact for STD or INST Trips

Alarm contact for Ground fault, Earth leakage trips or 2nd Pre-alarm contact

Pre-alarm contact

Temperature alarm contact

Error alarm contact

For external ZCT

For Neutral CT

For external display DP2

For Interface unit

For VT unit

CC

M

UVT

AX

AL

CLS

SBC

CL

Accessory Symbols

SHT Shunt tripping device

Closing coil

Motor(Motor charging device)

UVT coil

Auxiliary switch

OCR alarm switch

Charge limit switch

Shorting b-contact

Cell switch

Internal wiring

External wiring (user's wiring)

Control circuit connecter (drawout type)

51

+

41

+

31

+

21

+

11

+

53

+

43

+

33

+

23

+

13

+

341

+

331

+

321

+

311

+

Cell switch

52 42 32 22 12 54 44 34 24 14 344 342 334 332 324 322 314 312

Auxiliary switch (“b” contact) Auxiliary switch (“a” contact)

UVT controller voltage application

For 100-120 V AC

For 200-240 V AC

DC ratings

Apply voltage

D2 D1

For 380-460 V AC

Apply voltage

IN2 IN1

External unit

OUT4 OUT3

D2 D1

Control circuit terminal block

Applicable crimp terminal

A A

A = 7.2 mm or less

Applicable crimp-type terminals for M3.5 screws with an outer diameter of 7.2 mm or less.

(Wire size 1.25 mm 2 to 2.0 mm 2 )

Cell switch

˜

˜

For the drawout type, the cables should have the length which allow the control circuit terminal block to be moved to the left or right by 5mm.

When a coil load is connected in the same control circuit as the ETR, surge absorbers are required to absorb the surge voltage.

˜ OCR alarm (AL)

The contact output of the OCR alarm (Standard type AL) is the one-pulse output and the output time is 30~50ms.

For this reason, this output needs self-holding circuit.

˜ For Power supply type P3 and P4, the high sensitive relay used in contact output may cause the chattering noise (wrong output of 1ms level) during ON and OFF operation, depending on the

Panel placing condition. When it is used in the quick responsive sequence, the filter circuit of a few milli-second (ms) should be provided or the double reading sampling should be implemented.

˜

˜

Closing coil (CC)

As CC is one-pulse driven, it is not necessary to insert AXb for burning prevention purposes.

Inserting AXb will cause anti-pumping function to be ineffective.

Under voltage trip device (UVT)

Use the switch that can open and close 150V DC, 0.5A for remote trip.

Remote trip terminal has short bar at shipment, so remove it before using this function.

Disconnect the voltage input wires during dielectric testing of main circuit.

˜ Since some terminals are polarized, the wiring should be done correctly as the polarity shown in the wiring diagram when the control voltage is DC. Auxiliary switch (AX) Standard type has no polarity.

˜ Alarm reset (Terminal: RS1 and RS2 ) is available only for Power supply type P3, P4 and P5.

For Power supply type P1 and P2, it can not be reset from the Control circuit terminal block ( RS1 and RS2 ).

˜ 513 574 P3 P4

˜ FG (Terminal: P4 ) is the protective earth for power supply (Terminal: P1 , P2 ).

It is recommended to use this terminal to reduce surge (M8 screw required).

˜ Shorting b-contact (SBC)

SBC can be provided for all AX b contacts. At the time of shipment from factory, SBC is already connected to control circuit terminal block. Only one more crimp terminal can be added on contact, overlapping with SBC’s contact on Terminal: 11 ~ 51 .