C Setting up the Barcode Reader
About setting up the Barcode Reader
About setting up the Barcode Reader
About this topic
This topic describes the Barcode Reader and provides the workflow for setting up the Barcode Reader. To operate the Barcode Reader, see the
VWorks
Automation Control User Guide
.
Barcode Reader description
The Barcode Reader consists of a platepad with a barcode reader sensor head
(under the platepad) and a mirror. The Barcode Reader can be installed in place of a platepad at any deck location and is designed to scan barcodes on the east or west side of microplates.
Figure Barcode Reader oriented to scan barcodes on the east side of microplates
Mirror
00274
Overall Bar Code Reader with mirror
166
Platepad Barcode reader sensor head
(under the platepad)
Setup workflow
The following table presents the workflow for installing and setting up the
Barcode Reader. The procedures can vary depending on the brand of barcode reader sensor head (for example, Keyence or Microscan).
Step Procedure
1
2
3
4
Verify the barcode requirements.
Install the Barcode Reader.
See...
“Barcode label specifications” on page 167
“Installing or removing the Barcode
Add the Barcode Reader device and create a profile for the Barcode Reader.
“Creating a profile for the Barcode
Specify the Barcode Reader location in the Bravo device file.
“Specifying the Barcode Reader location” on page 171
Bravo Automated Liquid-Handling Platform User Guide
C Setting up the Barcode Reader
About setting up the Barcode Reader
Step Procedure
5
See...
Adjust the Barcode Reader for optimal scanning.
“Testing and optimizing barcode scanning” on page 173
Barcode label specifications
The barcode reader can read barcodes that meet the following requirements:
Characteristic
Barcode height
Print contrast
Quiet zone
Keyence requirements
Barcode symbology Code 39
Code 128
Interleaved 2 of 5
Code 93
Microscan requirements
Code 39
Codabar
Code 128
Interleaved 2 of 5
Code 93
Code 2 of 5
3.34 mm (0.13 in) or taller
25% at 650 nm
3.34 mm (0.13 in) or taller
25% at 650 nm
10 times the dimension of the narrowest element in the barcode or 0.25 in, whichever is greater
10 times the dimension of the narrowest element in the barcode or 0.25 in, whichever is greater
Note: The symbology must be stored in the barcode reader in order for the barcode reader to decode the barcode symbol.
Related information
For information about...
Setting up other accessories
Using an accessory in a protocol
See...
•
“Accessories and platepads” on page 101
•
“Autofilling accessories” on page 155
VWorks Automation Control User
Guide
Bravo Automated Liquid-Handling Platform User Guide 167
advertisement
Related manuals
advertisement
Table of contents
- 7 Preface
- 8 About this guide
- 9 Accessing Automation Solutions user information
- 15 Introduction to the Bravo Platform
- 16 Safety notes
- 17 About the Bravo Platform
- 19 Hardware overview
- 23 Connection panel description
- 26 Pipette heads and pin tools
- 29 Software overview
- 31 Setting up the Bravo Platform
- 32 Workflow for setting up the Bravo Platform
- 33 Starting up and shutting down
- 35 Creating or adding a Bravo device
- 40 Opening Diagnostics
- 42 Creating and managing profiles
- 46 Initializing the Bravo Platform
- 50 Setting teachpoints
- 57 Verifying the gripper setup
- 59 Configuring external robot access
- 69 Preparing for a protocol run
- 70 Workflow for preparing a protocol run
- 70 Emergency stops
- 71 Planning for the protocol run
- 72 About performing dry runs
- 73 Maintaining the Bravo Platform
- 74 Routine maintenance
- 75 Cleaning the Bravo Platform
- 76 Cleaning up after a run
- 77 Changing the Bravo head
- 83 Replacing the fuse
- 84 Retracting tip box stripper pins
- 86 Moving the head manually
- 87 Recovering from a head collision
- 89 Troubleshooting hardware problems
- 91 Troubleshooting hardware-related error messages
- 92 Reporting problems
- 95 Using Bravo Diagnostics
- 96 About the Jog/Teach tab
- 98 Homing the pipette head
- 100 Jogging the pipette head
- 102 Changing the pipette head speed
- 103 Using the Move and Approach commands
- 105 Fine-tuning the gripper movements
- 111 Clearing motor faults and checking the head type
- 112 Performing a task using Bravo Diagnostics
- 115 Accessories and platepads
- 116 Accessories overview for the Bravo Platform
- 118 Installing the Accessories Hub
- 121 Setting up a Microplate Vacuum Alignment Station
- 126 Setting up the Orbital Shaking Station
- 132 Using the teach plate to set the teachpoint for an accessory
- 134 Setting up the Vacuum Filtration Station
- 147 Configuring a platepad for delidding
- 148 Installing an Alignment Station
- 150 Setting up a Nested Rack Insert
- 153 Using the Manual Fill Reservoir
- 154 Setting up the Thermal Station
- 157 Setting up thermal and shaking stations (Inheco controller)
- 165 (Bravo SRT only) Setting up an LT tip box location
- 169 Autofilling accessories
- 170 Autofilling station overview and setup workflow
- 171 Configuring an autofilling station for the Bravo Platform
- 176 Setting up a Weigh Station for the Bravo Platform
- 179 Setting up the Barcode Reader
- 180 About setting up the Barcode Reader
- 182 Installing or removing the Barcode Reader
- 183 Creating a profile for the Barcode Reader
- 185 Specifying the Barcode Reader location
- 187 Testing and optimizing barcode scanning
- 193 Setting up the AssayMAP Bravo Platform
- 194 AssayMAP Bravo Platform overview
- 197 Bravo 96AM Head overview
- 202 AssayMAP cartridge overview
- 204 About installing the AssayMAP Bravo Platform
- 205 Installing and using the Bravo 96AM Head
- 213 Installing the 96AM Wash Station
- 217 Setting up the AssayMAP Bravo Platform
- 220 Setting teachpoints for the AssayMAP Bravo Platform
- 223 Verifying and adjusting teachpoints for the accessory locations
- 231 Opening the Protein Sample Prep Workbench
- 232 Requirements for partial-head liquid handling
- 237 Diagnostics quick reference
- 238 Bravo Diagnostics dialog box
- 239 Configuration tab quick reference
- 242 Accessory Diagnostics dialog box
- 243 External Robots tab quick reference
- 244 IO tab quick reference
- 246 Jog/Teach tab quick reference
- 250 Gripper tab quick reference
- 252 Profiles tab quick reference
- 256 Processes tab quick reference
- 259 Aspirate task parameters
- 263 Dispense task parameters
- 265 Dispense to Waste task parameters
- 269 Mix task parameters
- 272 Pump Reagent parameters
- 273 Shake task parameters
- 275 Vacuum Filtration Station task parameters
- 278 Wash Tips task parameters
- 281 Pin Tool task parameters
- 285 AM Aspirate task parameters
- 290 AM Dispense task parameters
- 295 AM Mix task parameters
- 299 Index