AssayMAP Bravo Platform overview

AssayMAP Bravo Platform overview

This topic provides an overview of the platform components and standard hardware configurations.

Hardware components overview

The AssayMAP Bravo Platform can enable high- throughput microchromatography for small- scale sample preparation. The following figure shows the components required for the AssayMAP Bravo Platform. The Bravo

Platform must include the gripper assembly, which is required for removing the mounted AssayMAP cartridges and disposable tips from the Bravo 96AM Head.

For a detailed description of the Bravo Platform and gripper assembly, see

“Hardware overview” on page 5

.

Figure AssayMAP Bravo Platform required components

180

Item Name

1

Bravo 96AM Head

Description

The 96- channel head that can transfer liquids with the bare probes of the syringes, through AssayMAP cartridges mounted on the probes, and using 250- µL disposable tips mounted on the probes. For a

detailed description, see Bravo 96AM Head overview .

Bravo Automated Liquid-Handling Platform User Guide

D Setting up the AssayMAP Bravo Platform

AssayMAP Bravo Platform overview

Item Name

2

Description

AssayMAP cartridge The microchromatography cartridge for small- scale sample preparation. Each cartridge features a 5- µL bed that is packed with chromatographic resin to support a variety of applications. Liquid can be aspirated or dispensed through the packed resin in the cartridges.

The AssayMAP Bravo Platform provides the precision flow- rate control required for aspirating or dispensing the fluid through the packed resin in the cartridges.

For a detailed description, see

AssayMAP cartridge overview .

3

4

96AM Cartridge &

Tip Seating Station

AssayMAP autofilling station

Pump

Module 2.0

The metal rack that holds the AssayMAP cartridges during runs and supports the cartridges when they are mounted on the probes. The seating station is also required for mounting fewer than 96 tips on the head.

Note: The Cartridge Transfer Utility protocol transfers the cartridges automatically from the conventional cartridge rack into the seating station.

The autofilling station that consists of the Pump Module 2.0, tubing kit, and 96AM Wash Station.

The Pump Module supplies liquid to the 96AM Wash Station for washing operations, and it removes the waste liquid during washing operations.

Tubing kit with inline filter

Ensure that the inline filter is connected in the input tubing line between Pump Module and the 96AM Wash Station to help prevent any tubing particulates from potentially clogging the chimneys of the 96AM Wash Station.

96AM Wash

Station

The 96- chimney reservoir for washing the probes, mounted cartridges, and mounted tips of the Bravo 96AM Head. The chimneys in the wash station prevent carryover and reduce contamination. The liquid enters the 96AM Wash Station through two input ports and then flows up through the chimneys to wash the cartridges, tips, or probes. The waste overflows from the chimneys and is removed through two outlet ports.

CAUTION

Using a model of the Tip Wash Station other than the 96AM Wash Station can result in a potential crash with the Bravo 96AM Head. Ensure that you use only the 96AM

Wash Station.

Configuration options to support AssayMAP applications

Different AssayMAP applications require slightly different hardware configurations. The following figure and table describe the two standard hardware configurations.

Bravo Automated Liquid-Handling Platform User Guide 181

D Setting up the AssayMAP Bravo Platform

AssayMAP Bravo Platform overview

Figure Standard configurations: (

A

) basic and (

B

) enhanced

182

Configuration AssayMAP Bravo Platform with…

A

Basic

B

Enhanced

AssayMAP applications

96AM Wash Station (

1

) (autofilling station) at deck location 1

Standard applications that do not require temperature control, such as Antibody

Purification

• 96AM Wash Station (autofilling station) (

1

) at deck location 1

• Peltier Thermal Station (

2

) with a custom plate nest and PCR plate insert at deck location 4

Bravo risers are required to accommodate the height

• Orbital Shaking Station (

3

) at deck location 9

Applications that require temperature control, such as

N- glycan Sample Prep or In- Solution Digestion

Software overview

The Protein Sample Prep Workbench is an interface that provides a collection of AssayMAP workflows, protocols, and forms for running protein sample prep applications on the AssayMAP Bravo Platform. The Protein Sample Prep

Workbench includes the following:

• Workflow Library

• Application Library

• Utility Library

• Literature Library

The VWorks software is required for the Protein Sample Prep Workbench. You set up the AssayMAP Bravo Platform using the VWorks software.