Device Configuration. Maretron DSM250-01

Add to My manuals
265 Pages

advertisement

Device Configuration. Maretron DSM250-01 | Manualzz

DSM250 User’s Manual

6 Device Configuration

The “Device Configuration…” menu enables you to configure certain types of devices on the NMEA

2000 ® network. Devices that may be configured using the DSM250 include the following:

Airmar Depth, Speed, and Temperature Transducers (DST800, DT800, P39, P79, B122,

ST850, ST800, HT200) – Reset trip log, set depth offset, speed calibration, and temperature offset (if applicable)

Bennett EP-30 – Calibrate trim tabs.

Maretron Alternating Current Monitor (ACM100) – Set circuit type, device type, instance number, and label. Reset the total energy recorded.

Maretron Annunciator (ALM100) – Set the Data Instance Number, and the Label. Test the alarm.

Maretron Direct Current Monitor (DCM100) – Set the Battery Type, and calibrate the current sensor zero offset.

Maretron Direct Current Relay Module (DCR100) – Set the operating mode of each channel, lock switches, set power up state, and control state of switches

Maretron Monochrome Display (DSM200)

– allows configuration of other DSM200s on the network

Maretron Color Display (DSM150,DSM250) – allows configuration of other DSM150s and

DSM250s on network

Maretron Depth/Speed/Temp. Transducer (DST100) – set transducer offset, zero trip distance log

Maretron Depth/Speed/Temp. Transducer (DST110) – Reset trip log, set depth offset, speed calibration, and temperature offset

Maretron Engine Monitoring System (EMS100) – set the gauge types for Boost Pressure, Drive

Trim, Oil Pressure and Water Temperature. Preset the Engine Hours

Maretron Fuel Flow Monitor (FFM100)

– Set operating mode, channel direction, K-factor, temperature coefficient

Maretron Fluid Pressure Monitor (FPM100) – Set the operating mode of each channel, perform tank levels calibration, set pressure sender characteristics

Maretron GPS Antenna/Receiver (GPS100) – enable and disable WAAS functionality, set the

GPS mode, program the elevation, PDOP and SNR masks, set the antenna altitude, force a cold start, enable/disable individual PGN transmission, and reset the unit back to its factory defaults.

Maretron GPS Antenna/Receiver (GPS200) – enable and disable WAAS functionality, force a cold start, enable/disable individual PGN transmission, and reset the unit back to its factory defaults.

Maretron Internet Protocol Gateway(IPG100) – set IP connection parameters, set N2KServer password, view N2KServer information, and reset the unit back to its factory defaults.

Maretron J1939 to NMEA 2000 Gateway (J2K100)

– set J1939 node address, set NMEA 2000 ® engine/transmission instance, enable pass-through of J1939 diagnostic messages, and enable/disable individual NMEA 2000 ® PGN transmissions.

Maretron Network Bus Extender (NBE100) – Set device label

Maretron Rudder Angle Adapter (RAA100)

– Set rudder number, operating mode, and calibrate rudder position.

Page 44 Revision 1.4.16a

Maretron Run Indicator Monitor (RIM100)

– Set Data Instance for the device, and labels for the device and each channel.

Maretron Switch Indicator Monitor (SIM100) – Set Data Instance for the device, and labels for the device and each channel. Set each channel mode.

Maretron Solid Sate Compass (SSC200)

– set installation offset, perform magnetic deviation calibration, check magnetic deviation calibration status, invert installation, configure magnetic variation settings, setup NMEA0183 interface, program rate of turn damping, zero the rate-ofturn offset, and enable/disable individual NMEA 2000 ® PGN transmissions.

Maretron Tank Level Adapter (TLA100) – Set tank type and tank number, set operating mode, set tank capacity, and calibrate for irregular shaped tanks.

Maretron Tank Level Monitor Shallow (TLM100)

– Set tank type and tank number, set operating mode, set tank capacity, and calibrate for irregular shaped tanks.

Maretron Tank Level Monitor Gasoline (TLM150) – Set tank type and tank number, set operating mode, set tank capacity, and calibrate for irregular shaped tanks.

Maretron Tank Level Monitor Deep (TLM200)

– Set tank type and tank number, set operating mode, set tank capacity, and calibrate for irregular shaped tanks.

Maretron Temperature Monitor (TMP100) – Set device label and channel instance, temperature source (type) and label.

Maretron NMEA 2000 to USB gateway (USB100) – allows configuration of USB100s on network

Maretron Vessel Data Recorder (VDR100) – Set device label

Maretron Ultrasonic Wind and Weather Station (WSO100)

– set installation offset, set wind damping rates, and enable/disable individual NMEA 2000 ® PGN transmissions.

More device types will be included in future firmware releases.

In each case, the contents of the Device Configuration menus may vary depending on the version of the firmware within the device.

The “Device Configuration…” menu is shown in Figure 32.

Figure 32 – Device Configuration Screen

The “NA” column of the menu displays the node address the device is using.

The “Manufacturer” column of the menu displays the manufacturer of the device.

The “Model” column displays the model number of the device.

Revision 1.4.16a Page 45

DSM250 User’s Manual

The “SN#” column displays the serial number of the device, so that any of two or more devices of the same manufacturer and model number may be distinguished from one another.

The “HW” column shows the device hardware version.

The “SW” column shows the device software version (firmware version).

Page 46 Revision 1.4.16a

advertisement

Related manuals

advertisement

Table of contents