DSM250 User’s Manual

Figure 215 – TMP100 Channel Configuration Screen

6.27.2.1 Instance

The Data Instance of the Temperature (as sent in PGNs 130311, 130312, and 130823) is set in this field. Use the Increase and Decrease buttons to select the correct instance number, and the press the Enter button to store it.

6.27.2.2 Source

In the NMEA2000 ® PGNs, each temperature is associated with a source type. Possible values are:

Bait Well Temperature

Engine Room Temperature

Exhaust Gas Temperature

Freezer Temperature

Heating System Temperature

Inside Temperature

Live Well Temperature

Main Cabin Temperature

Outside Temperature

Refrigeration Temperature

Sea Temperature

User Defined Temperature #129...#144 – Use this when none of the above options are suitable.

Use the Scroll Up and Scroll Down buttons to select the correct source, and the press the Enter button to store it.

6.27.2.3 Label

A label may be assigned to each channel of the TMP100 as an aid to identifying the temperature that is being displayed. Typically this label will describe the function or location of the temperature sensor.

6.27.3 Device Label

A label may be assigned to the TMP100 as an aid to identifying the device over the network. Typically this label will describe the location of the TMP100.