Declaring axes control modules
Introduction This operation consists in declaring the axes control modules in the PLC configuration.
TLX DS 57 PL7 40E 09.2000
53
Configuration
Adding a module To add an axes control module into the PLC configuration, proceed in the following way:
Step
1
2
Action
Select the rack in which you want to install the axes control module by clicking on the corresponding rack.
In the rack, select and confirm the position in which you want to install the TSX module by clicking on it twice.
The following dialog box allows you to add the module to the configuration:
Add module
Family:
Analog Module 1.5
Communication1.5
Counting 1.5
Remote BusX 1.0
Movement 1.5
Wheighing
Simulation
Discrete
1.5
1.0
1.5
Module:
TSX CAY 21
CAY 33
TSX CAY 41
TSX CAY 42
TSX CFY 11
TSX CFY 21
2 CHAN. AXIS CONT. MOD
MOD.CDE AXE 3
4 CHAN. AXIS CONT. MOD
4 CHAN. AXIS CONT. MOD
1 CH STEPPER MOTOR MOD.
2 CH STEPPER MOTOR MOD.
OK
Cancel
5
6
3
4
Select Movement in the Family field.
Select the reference of the module (TSX CFY) in the Module field.
Confirm with OK.
After confirmation, the module is declared in its position.
Configuration
TSX 57203 XMWI
XTI..
0
2
6
0
0
P
S
Y
0
5
7
2
0
3
T
S
X
2 3
D
E
Y
3
2
D
2
K
4
D
S
Y
3
2
T
2
K
5 6
1
5
5
0
0
P
S
Y
1 2 3
2
1
C
F
Y
4 5 6
2
54
TLX DS 57 PL7 40E 09.2000
Configuration
Deleting a module
To delete a module from its postion: l l l click on it to select it, press the Del key, which displays a dialog box,
Confirm the deletion of the module.
Moving a module To move a module from one position to another: l l l l l click on it to select it, activate the command Edit
Fix the destination position.
You can also:
→
Move a module, select the module using the mouse, without releasing the left mouse button, move the module to its destination position (Drag and Drop).
TLX DS 57 PL7 40E 09.2000