Reconfiguration in connected mode. Schneider Electric PL7 Junior/Pro - Premium PLC Application-specific functions - Step-by-step axis control
Werbung
Werbung
Adjustment
Reconfiguration in connected mode
Introduction When configuration parameters are modified, you must confirm these parameters using the command Edit
→
Confirm or by clicking on the icon.
Parameters which can be modified in connected mode
Only parameters that are not grayed out can be modified in connected mode. Other parameters like activation of an event task must be modified in local mode. Every time that you reconfigure, the corrected resolution becomes the initial resolution.
Stopping the movement in progress
All configuration in connected mode brings about a stop in the operation of the channel concerned and thus the stopping of the movement in progress. This is signaled by a dialog box:
Validate
Reconfiguration will STOP channel 0.
Are you sure you want to reconfigure channel 0?
Yes No
136
TLX DS 57 PL7 40E 09.2000
Adjustment
Parameter exchange when reconfiguring
The following diagram presents the parameter exchanges when reconfiguring in connected mode:
Configuration screen (1) PLC processor Axes control channel
Parameters for configuring
Parameters for configuring
Reconfiguration
Parameters for configuring
Current adjustment parameters
Current adjustment parameters
Current adjustment parameters
Initial adjustment parameters
(1) or adjustment screen if a configuration parameter has first been modified in the configuration screen.
TLX DS 57 PL7 40E 09.2000
137
Adjustment