TECHNICAL DATA

TECHNICAL DATA

Compressors are designed to operate in dry, ventilated and indoor dust-free rooms with the following climatic conditions:

Temperature

Relative humidity from +5 °C to +30°C max. 50%

Working pressure 6 – 8 bar

Nominal voltage

Frequency a)

Capacity at 6 bar (FAD)

Working pressure b)

Rated current

Motor power

Air tank volume

Air quality – filtration

Maximum operating pressure of safety valve

Noise level at 5 bar (L pA

)

Operating mode

PDP drying at 7 bar

Dryer low pressure warning

Dryer high pressure warning

Dryer high dew point warning

Time to fill air tank from 0 to 7 bar

Dimensions (net) w x d x h

Net weight c)

V, Hz bar dB

%

°C bar l/min bar

A kW l

 m bar

°C s mm kg

DK50 2V/M

230, 50

120

6.0 – 8.0

8.8

1.2

25

-

11.0

≤69.0

S1-100

-20

< 3

˃ 9

˃ -20

90

460x620x720

69

DK50 2V S/M

230, 50

120

6.0 – 8.0

9.0

1.2

25

-

11.0

≤55.0

S1-100

-20

< 3

˃ 9

˃ -20

90

560x720x880

110 a) State the compressor variant in the order b) For other range of pressure consult with the supplier c) Weight value is only informative data and applies only to a product without any accessories

NP-DK50 2V-A-5_12-2022-AD 16 12/2022

TECHNICAL DATA

Dependence of compressor output on working pressure

12/2022 17 NP-DK50 2V-A-5_12-2022-AD

TECHNICAL DATA

Working pressure 6 – 8 bar

Nominal voltage

Frequency a)

Capacity at 6 bar (FAD)

Working pressure b)

Rated current

Motor power

Air tank volume

Air quality – filtration

Maximum operating pressure of safety valve

Noise level at 5 bar (L pA

)

Operating mode

PDP drying at 7 bar

Dryer low pressure warning

Dryer high pressure warning

Dryer high dew point warning

Time to fill air tank from 0 to 7 bar

Dimensions (net) w x d x h

Net weight c)

V, Hz bar dB

%

°C bar l/min bar

A kW l

 m bar

°C s mm kg

DK50 2V/M

230, 50

115

6.0 – 8.0

8.8

1.2

25

-

11.0

≤69.0

S1-100

-40

< 3

˃ 9

˃ -40

100

460x620x720

69

DK50 2V S/M

230, 50 a) State the compressor variant in the order b) For other range of pressure consult with the supplier c) Weight value is only informative data and applies only to a product without any accessories

Dependence of compressor output on working pressure

115

6.0 – 8.0

9.0

1.2

25

-

11.0

≤55.0

S1-100

-40

< 3

˃ 9

˃ -40

100

560x720x880

110

NP-DK50 2V-A-5_12-2022-AD 18 12/2022

TECHNICAL DATA

Working pressure 6 – 8 bar

Nominal voltage

Frequency a)

Capacity at 6 bar (FAD)

Working pressure b)

Rated current

Motor power

Air tank volume

Air quality – filtration

Maximum operating pressure of safety valve

Noise level at 5 bar (L pA

)

Operating mode

PDP drying at 7 bar

Dryer low pressure warning

Dryer high pressure warning

Dryer high dew point warning

Time to fill air tank from 0 to 7 bar

Dimensions (net) w x d x h

Net weight c)

V, Hz bar dB

%

°C bar l/min bar

A kW l

 m bar

°C s mm kg

DK50 2V/M

230, 50

100

6.0 – 8.0

8.8

1.2

25

-

11.0

≤69.0

S1-100

-70

< 3

˃ 9

-68

110

460x620x720

69

DK50 2V S/M

230, 50 a) State the compressor variant in the order b) For other range of pressure consult with the supplier c) Weight value is only informative data and applies only to a product without any accessories

Dependence of compressor output on working pressure

100

6.0 – 8.0

9.0

1.2

25

-

11.0

≤55.0

S1-100

-70

< 3

˃ 9

-68

110

560x720x880

110

12/2022 19 NP-DK50 2V-A-5_12-2022-AD

TECHNICAL DATA

Working pressure 8 – 10 bar

Nominal voltage

Frequency a)

Capacity at 8 bar (FAD)

Working pressure b)

Rated current

Motor power

Air tank volume

Air quality – filtration

Maximum operating pressure of safety valve

Noise level at 5 bar (L pA

)

Operating mode

PDP drying at 7 bar

Dryer low pressure warning

Dryer high pressure warning

Dryer high dew point warning

Time to fill air tank from 0 to 7 bar

Dimensions (net) w x d x h

Net weight c)

V, Hz bar dB

%

°C bar l/min bar

A kW l

 m bar

°C s mm kg

DK50 2V/M

230, 50

100

8.0 – 10.0

8.6

1.2

25

-

11.0

≤69.0

S1-100

-20

< 3

˃ 11

˃ -20

115

460x620x720

71

DK50 2V S/M

230, 50 a) State the compressor variant in the order b) For other range of pressure consult with the supplier c) Weight value is only informative data and applies only to a product without any accessories

Dependence of compressor output on working pressure

100

8.0 – 10.0

8.8

1.2

25

-

11.0

≤55.0

S1-100

-20

< 3

˃ 11

˃ -20

115

560x720x880

112

NP-DK50 2V-A-5_12-2022-AD 20 12/2022

TECHNICAL DATA

Working pressure 8 – 10 bar

Nominal voltage

Frequency a)

Capacity at 8 bar (FAD)

Working pressure b)

Rated current

Motor power

Air tank volume

Air quality – filtration

Maximum operating pressure of safety valve

Noise level at 5 bar (L pA

)

Operating mode

PDP drying at 7 bar

Dryer low pressure warning

Dryer high pressure warning

Dryer high dew point warning

Time to fill air tank from 0 to 7 bar

Dimensions (net) w x d x h

Net weight c)

V, Hz bar dB

%

°C bar l/min bar

A kW l

 m bar

°C s mm kg

DK50 2V/M

230, 50

95

8.0 – 10.0

8.6

1.2

25

-

11.0

≤69.0

S1-100

-40

< 3

˃ 11

˃ -40

120

460x620x720

71

DK50 2V S/M

230, 50 a) State the compressor variant in the order b) For other range of pressure consult with the supplier c) Weight value is only informative data and applies only to a product without any accessories

Dependence of compressor output on working pressure

95

8.0 – 10.0

8.8

1.2

25

-

11.0

≤55.0

S1-100

-40

< 3

˃ 11

˃ -40

120

560x720x880

112

12/2022 21 NP-DK50 2V-A-5_12-2022-AD

TECHNICAL DATA

FAD correction of capacity for altitude

Capacity given in the form of FAD („Free Air Delivery“) applies to the following conditions:

Altitude 0 m.n.m.

Atmospheric pressure 101325 Pa

Temperature

Relative humidity

20°C

0%

To calculate FAD compressor capacity in dependence on altitude, it is necessary to apply correction factor according to the following table:

Altitude [m.n.m.]

FAD correction factor

0 -1500

1

1501 - 2500

0,8

2501 - 3500

0,71

3501 - 4500

0,60

NP-DK50 2V-A-5_12-2022-AD 22 12/2022