OPERATION

16. SWITCHING ON THE COMPRESSOR

Start the compressor (without a cabinet) at the pressure switch (1) by turning the switch (2) to position “I.” This starts the compressor and fills the tank to the switching off pressure, which then shuts off the compressor.

Start the compressor (with a cabinet) at the switch (5) on the front side of the cabinet. This starts the compressor and fills the tank to the switching off pressure, which then shuts off the compressor.

The compressor operates in automatic mode, switched on and off by the pressure switch, depending on compressed air consumption.

Check the values of the switch-on and switch-off pressure using the pressure gauge (3). A tolerance of ± 10% is acceptable. The pressure in the air tank must not exceed the permitted operating pressure.

Fig. 17:Switching on the compressor

Compressor – when first started and placed into service, the compressor fills the air tank until the switching pressure and the pressure switch turn off the compressor. The compressor operates in automatic mode, switched on and off by the pressure switch, depending on compressed air usage.

When the compressor is running, the compressed air passes through a cooler and a dryer that removes moisture from the compressed air.

Condensate is also blown out of the drain on the dryer, which can be heard as a hiss when the compressor shuts down or when the drying chambers switch.

Risk of damage to pneumatic parts.

The pressure switch (1) was set up by the manufacturer and any other changes to it settings may be performed only by a qualified technician trained by the manufacturer.

17. SWITCHING OFF THE COPRESSOR

Switching off the compressor due to service or any other reason shall be performed using

the pressure switch (1) by turning the switch (2) to position „0“ (Fig. 17) and

pulling out the mains plug from the socket . This disconnects the compressor from the mains supply

Vent the pressure in the air tank to zero by opening the drain valve.

12/2022 39 NP-DK50 2V-A-5_12-2022-AD