MAIN SCREENS. EKOM DK50 2V

Add to My manuals
232 Pages

advertisement

MAIN SCREENS. EKOM DK50 2V | Manualzz

AD DRYER the service menu in the SERVICE SETUP section. Access to the service menu is protected by a code.

Reset and adjustment of service intervals, reviewing service and alarm messages

Adjustment of the dryer pressure version

Adjustment of the dryer mode

The drying mode is set based on the expected pressure range in which the device will operate and the version of the compressor (with or without a cabinet).

compressor without a cabinet t

O

< 25 ̊C - set to ECONOMY mode

compressor without a cabinet t

O

= 25 ̊C - 30 ̊C - set to STANDARD mode

compressor without a cabinet t

O

> 30

̊C - set to ENHANCED mode

compressor in cabinet - set to ENHANCED mode t

O

- ambient temperature

20. MAIN SCREENS

The home screen opens once the user interface language and drying mode are set. There are 4 main screens accessed from the home screen.

The arrows at the bottom of the screen are used to navigate between the individual screens.

20.1. Home screen

Hour meter

Dryer operating mode

Current dew point*

Current pressure in dryer

Switch to display dryer operation

12/2022

Time to next service

Switch selection to language

(*this information is only shown if the compressor is equipped with a dew point sensor)

43 NP-DK50 2V-A-5_12-2022-AD

AD DRYER

- Basic information and measured parameters are shown on the dryer home screen. The dryer operating hours indicator is located at the top of the screen. The home screen has 4 main tiles that display the following information:

-

Dryer operating mode (see chap. 19.1)

- Current pressure in the dryer (min. working pressure to activate dryer regeneration is 3 bar)

- Current pressure dew point value (only for compressors equipped with dew point sensors)

-

Remaining time to the next service interval (see chap.21.1, 21.2

– service intervals).

20.2. Dryer operation screen

Operating hours indicator

Hour meter

Chamber designation

Symbol for chamber pressure equalisation phase

Status icon for the right chamber

Status icon for the left chamber

Arrow to navigate back to the home screen

The dryer operating hours indicator is located at the top of the screen. The dryer operation screen is also divided into 4 sections, which describe the dryer chamber working cycles using a graphical depiction of the operating states of each chamber.

Symbol for when the dryer chamber is currently in regeneration.

Symbol for when the dryer chamber is currently drying.

0

Symbol for chamber pre-filling – equalisation of pressure in chambers.

NP-DK50 2V-A-5_12-2022-AD 44 12/2022