PNEUMATIC CONNECTION. EKOM DK50 2V

Add to My manuals
232 Pages

advertisement

PNEUMATIC CONNECTION. EKOM DK50 2V | Manualzz

INSTALLATION

Remove transport fixing elements from the pumps (Fig. 5).

Prior to installation, ensure that the compressor is free of all transport packaging and stabilizers to avoid any risk of damage to the product.

Remove fixing elements of the pumps once the compressor has been assembled and balanced at the final installation place.

Fig. 5: Releasing the pump

11. PNEUMATIC CONNECTION

11.1. Connecting to the compressed air outlet

Connect the pressure hose (2) to the compressed air outlet (1) of the compressor (Fig. 6).

Secure the pressure hose in the clamp (3) (Fig. 6).

Route the pressure hose through the opening on the left side in the back wall of the cabinet

(Fig. 8) on compressors in cabinet.

Fig. 6:Connecting to the compressed air outlet

12/2022 25 NP-DK50 2V-A-5_12-2022-AD

11.2. Connecting the cabinet pressure gauge to the compressor

Remove the plug (1) from the threads (2) on the pneumatic block of the compressor.

Connect the cabinet pressure gauge hose to the threaded fitting.

INSTALLATION

Fig. 7: Connecting the cabinet pressure gauge to the compressor

11.3. Connecting the condensate vessel

Connect the condensate drain hose to the condensate bottle on compressors in cabinet.

(Fig. 8)

Put the plug in free inlet of the condensate collection vessel.

Route the hose through the opening in the rear wall of the cabinet for compressors with dryers. Connect the condensate collection tank using the hose to the condensate outlet on the dryer.

Injury hazard.

Do not connect the condensate drain directly to a waste drain! Passers-by may be injured!

Fig. 8:Connection of condensate collection vessel

NP-DK50 2V-A-5_12-2022-AD 26 12/2022

INSTALLATION

Risk of damage to pneumatic components.

Air hoses must not be broken.

11.4. Floor installation

Connect the compressor using the hoses prepared in advance in the floor, as per the installation plan.

Fig. 9: Floor installation

Description to Fig. 9:

1. Outline of the cabinet

4. Compressed air connection G3/8

2. Outline of the base

5. Power supply input

3. Front section - door

230V/50(60) Hz

All dimensions are in millimetres

3G1.0x4000

Distance from wall min. 100 mm

12/2022 27 NP-DK50 2V-A-5_12-2022-AD