advertisement
![1. GENERAL INFORMATION. Eldes EKB3 | Manualzz 1. GENERAL INFORMATION. Eldes EKB3 | Manualzz](http://s1.manualzz.com/store/data/001731187_1-63f6db8abae8ee33f0d3ba1fa4d45eb5-360x466.png)
1. GENERAL INFORMATION
1.1. Functionality
ESIM264 – micro-controller based alarm system for houses, cottages, country homes, garages and other buildings, also capable of managing electrical appliances via cellular GSM/GPRS network. It can also be used as Intercom system.
Examples of using the system:
• Property security.
• Alarm switch.
• Thermostat, heating and air-conditioner control, temperature monitoring.
• Lighting, garden watering, water pump and other electrical equipment control via SMS text messages.
• Remote listening to what is happening in the secured area.
• Main 230V power status with SMS text message.
• Two-way intercom device via GSM network.
1.2. Compatible Device Overview
EKB2
EKB3
EA1
EA2
Device
EPGM1
EPGM8
Wired Devices
Description
LCD keypad
LED keypad
Audio output module with 3,5mm jack
Audio amplifier module 1W 8Ω
16 zone and 2 PGM output expansion module
8 PGM output expansion module
4*
Max. Connectable Devices
4*
1**
1**
1
1**
EW1
Device
EW1B
EWP1
EWD1
EWD2
EWK1****
EWK2****
EWS1
EWS2
EWS3
EWF1
Wireless Devices
Description
Wireless 2 zone and 2 PGM output expansion module
Battery-powered wireless 2 zone and 2 PGM output expansion module
Wireless motion detector
Wireless magnetic door contact
Wireless magnetic door contact/shock sensor/water sensor
Wireless keyfob with 4 buttons
Wireless keyfob with 4 buttons
Wireless indoor siren
Wireless outdoor siren
Wireless indoor siren
Wireless smoke detector
Max. Connectable Devices
16***
16***
16***
16***
16***
5***
5***
16***
16***
16***
16***
* - A mixed combination of EKB2 and EKB3 keypads is supported. The combination can consist of up to 4 keypads in total.
** - Only 1 of these modules can be connected at a time if the module slots are implemented in ESIM264 unit.
*** - A mixed combination of wireless devices is supported. The combination can consist of up to 32 wireless devices in total.
**** - A mixed combination of EWK1 and EWK2 keyfobs is supported. The combination can consist of up to 5 keyfobs in total.
1.3. Default Parameters & Ways of Parameter Configuration
Main Settings
Parameter Default Value
SMS & EKB2 Menu Language
SMS Password
User Password 1
User Password 2... 30
Administrator Password
Duress Password
SGS Password
Depends on firmware version according to user‘s location
0000
1111
N/A
1470
N/A
N/A
User 1... 5 Phone Number N/A
Allow Control from Any Phone Number Disabled
Date & Time
Exit Delay - Partition 1... 4
Info SMS Scheduler
N/A
15 seconds
Frequency (days) – 1; Time - 11
Configurable by:
SMS EKB2 EKB3
Configuration
Tool
66 EN MANUAL ELDES ESIM264 V3.1
Zones
Parameter Default Value
Zone Name
Entry Delay
On-Board Zone Delay
EPGM1 Zone Delay
On-board Z1 Zone Type
On-board Z2... Z12 Zone Type
Keypad Zone Type
EPGM1 Zone Type
Z1 - Zone 1; Z2 - Zone 2; Z3 - Zone 3; Z4 - Zone 4; Z5 -
Zone 5; Z6 - Zone 6
15 seconds
800 milliseconds
800 milliseconds
Delay
Instant
Instant
Instant
Wireless Zone Type
Virtual Zone Type
Depends on the connected wireless device
Interior Follower
ATZ Mode Disabled
6-Zone Mode: Zone Connection Type Type 1
ATZ Mode: Zone Connection Type
On-board Zone Status
Keypad Zone Status
EPGM1 Zone Status
Type 4
Enabled
Disabled
Enabled
Wireless Zone Status
Virtual Zone Status
Stay attribute for individual zone
Arm-Disarm by Zone
Force atrribute for individual zone
Tamper Name
Chime
Depends on the connected wireless device
Disabled
Disabled
N/A
Disabled
Tamper 1, Tamper 2, Tamper 3, Tamper 4, Tamper 5,
Tamper 6 etc.
Enabled
Configurable by:
SMS EKB2 EKB3
PGM Outputs
Parameter Default Value
PGM Output Name
PGM Output Status
EPGM8 PGM Output Status
EPGM1 PGM Output Status
Wireless PGM Output Status
Wireless PGM Output Type
PGM Output Control by Event 1... 16
PGM Output Control by Event Management
Scheduler 1... 16
Turn ON/OFF PGM Output by Timer
Using Module EPGM8 Mode
C1 – Controll1, C2 – Controll2, C3 – Controll3, C4 – Controll4 etc.
Disabled
Disabled
Disabled
Enabled
Depends on the connected wireless device
Disabled
Disabled
Disabled
Configurable by:
SMS EKB2 EKB3
Parameter Default Value
Alarm Duration
EWS2 LED
1 minute
Disabled
Bell Squawk Disabled
Activate Siren if Wireless Device is Lost Disabled
Alarm Duration & Siren
Configurable by:
SMS EKB2 EKB3
Configuration
Tool
Configuration
Tool
Configuration
Tool
MANUAL ELDES ESIM264 V3.1
EN 77
Parameter
Alarm Notifications & Arm/Disarm Notifications
Configurable by:
Default Value
SMS EKB2 EKB3
Call in Case of Alarm
Send Alarm SMS to All Users Simultaneously
Enabled
Disabled
Send Arm/Disarm SMS to User 1... 5 Enabled
Send Arm/Disarm SMS to All Selected
Users Simultaneously
Disabled
Main Power Status
Parameter
Main Power Loss Delay
Main Power Restore Delay
Default Value
30 seconds
120 seconds
Configurable by:
SMS EKB2 EKB3
Peripheral Devices
Parameter
Temperature Sensor MIN
Temperature Sensor MAX
Allow adding New iButton Keys
Default Value
0 °C
0 °C
Disabled
Configurable by:
SMS EKB2 EKB3
System Notifications
Parameter
General Alarm
System Disarmed
System Armed
Parameter
Enabled
Enabled
Enabled
Main Power Loss Event Enabled Enabled
Main Power Restore Event Enabled Enabled
Low Battery
Periodical Info
Enabled
Enabled
Tamper Alarm Event
Battery Failed
System Started
Wireless Signal Loss
Enabled
Enabled
Enabled
Enabled
Temperature Fallen
Temperature Exceeded
System Shutdown
Enabled
Enabled
Enabled
Configurable by:
SMS EKB2 EKB3
Partitions
Parameter
Partition 0 Name
Partition 1 Name
Default Value
PART0
PART1
Configurable by:
SMS EKB2 EKB3
Configuration
Tool
Configuration
Tool
Configuration
Tool
Configuration
Tool
Configuration
Tool
88 EN MANUAL ELDES ESIM264 V3.1
Partitions
Parameter
Keypad 1... 4 Partition
Keypad Partition Switch
User Password 1... 30 Partition
User 1... 5 Phone Number Partition iButton 1... 5 Partition
Zone Partition
Default Value
PART0
Disabled
PART0
PART0
PART0
PART0
Parameter Default Value
MS Mode
Data Messages
Account (Alarm System ID)
Monitoring Station Phone Number 1... 3
(Voice Calls/SMS)
Attempts (Voice Calls/SMS)
Monitoring Station Phone Number 1...
5 (CSD)
Attempts (CSD)
Server IP Address (GPRS)
DNS1 Server IP Address (GPRS)
DNS2 Server IP Address (GPRS)
Protocol (GPRS)
Server Port (GPRS)
Local Port (GPRS)
APN (GPRS)
User (GPRS)
Password (GPRS)
Profile (GPRS)
GPRS Attempts
Delay Between Attempts (GPRS)
Unit ID (GPRS)
Test Period (GPRS)
Communication - Primary
Communication - Backup 1... 4
Protocol over GPRS
Disabled
All Enabled
9999
N/A
3
N/A
3
0.0.0.0
N/A
N/A
UDP
20000
N/A
N/A
N/A
N/A
Profile1
3
600 seconds
0000
180 seconds
N/A
N/A
EGR100
Monitoring Station
Configurable by:
SMS EKB2 EKB3
Configuration
Tool
Configurable by:
SMS EKB2 EKB3
Configuration
Tool
MANUAL ELDES ESIM264 V3.1
EN 99
Parameter Default Value
Event Log
Microphone Gain
Speaker Level
GSM Signal Loss Indication - Delay
Enabled
12
85
180 seconds
GSM Signal Loss Indication - Activate
Output
N/A
Show ARMED Status in Keypad (EKB2) Disabled
Additional Parameters
Parameter
ELDES Smart Security
Server Address
Port
Ping Period
Time Zone
Default Value
ELDES Smart Security
Disabled ss.eldes.lt
8082
180 seconds
0
Configurable by:
SMS EKB2 EKB3
Configuration
Tool
Configurable by:
SMS EKB2 EKB3
Configuration
Tool
10 EN MANUAL ELDES ESIM264 V3.1
MANUAL ELDES ESIM264 V3.1
EN
advertisement
Related manuals
advertisement
Table of contents
- 6 1. GENERAL INFORMATION
- 6 1.1. Functionality
- 6 1.2. Compatible Device Overview
- 6 1.3. Default Parameters & Ways of Parameter Configuration
- 12 2. Technical Specifications
- 12 2.1. Electrical & Mechanical Characteristics
- 13 2.2. Main Unit, LED & Connector Functionality
- 14 2.3. Wiring Diagrams
- 20 3. INSTALLATION
- 24 4. GENERAL OPERATIONAL DESCRIPTION
- 25 5. CONFIGURATION METHODS
- 28 6. PASSWORDS
- 29 7. SYSTEM LANGUAGE
- 30 8. USER PHONE NUMBERS
- 31 8.1. System Control from any Phone Number
- 33 9. DATE AND TIME
- 34 10. USER PASSWORDS
- 36 11. iBUTTON KEYS
- 36 11.1. Adding and Removing iButton Keys
- 38 12. ARMING AND DISARMING
- 38 12.1. Free of Charge Phone Call
- 39 12.2. SMS Text Message
- 40 12.3. EKB2 Keypad and User Password
- 41 12.4. EKB3 Keypad and User Password
- 42 12.5. iButton Key
- 42 12.6. EWK1/EWK2 Wireless Keyfob
- 43 12.7. Arm-Disarm by Zone
- 44 12.8. Disabling and Enabling Arm/Disarm Notifications
- 46 13. EXIT AND ENTRY DELAY
- 48 14. ZONES
- 48 14.1. Zone Numbering
- 48 14.2. Zone Expansion
- 48 14.3. 6-Zone Mode
- 49 14.4. ATZ (Advanced Technology Zone) Mode
- 50 14.5. Zone Type Definitions
- 51 14.6. Zone Attributes
- 54 14.7. Bypassing and Activating Zones
- 54 14.8. Zone Names
- 55 14.9. Disabling and Enabling Zones
- 56 15. STAY MODE
- 57 16. TAMPERS
- 57 16.1. Tamper Names
- 58 17. ALARM INDICATIONS AND NOTIFICATIONS
- 59 17.1. Enabling and Disabling Alarm Notifications
- 62 18. PROGRAMMABLE (PGM) OUTPUTS
- 62 18.1. PGM Output Numbering
- 62 18.2. PGM Output Expansion
- 63 18.3. PGM Output Names
- 63 18.4. Turning PGM Outputs ON and OFF
- 65 18.5. PGM Output Control by Event and Scheduler
- 66 18.6. Wireless PGM Output Type Definitions
- 67 19. WIRELESS DEVICES
- 67 19.1. Binding, Removing and Replacing Wireless Devicess
- 69 19.2. Wireless Device Information and Signal Status Monitoring
- 70 19.3. Disabling and Enabling Siren if Wireless Signal is Lost
- 71 20. SIREN/BELL
- 72 20.1. Bell Squawk
- 72 20.2. Indication by EWS2 Indicators
- 73 20.3. EWF1 Interconnection
- 74 21. BACKUP BATTERY, MAINS POWER SUPPLY STATUS MONITORING AND MEMORY
- 77 22. GSM CONNECTION STATUS MONITORING
- 78 23. PARTITIONS
- 78 23.1. Zone Partition
- 78 23.2. User Phone Number Partition
- 79 23.3. Keypad Partition and Keypad Partition Switch
- 80 23.4. User Password Partition
- 80 23.5. iButton Key Partition
- 80 23.6. EWK1/EWK2 Wireless Keyfob Partition
- 81 24. TEMPERATURE SENSORS
- 81 24.1. Adding, Removing and Replacing Temperature Sensors
- 81 24.2. Setting Up MIN and MAX Temperature Boundaries. Temperature Info SMS
- 83 25. REMOTE LISTENING AND 2-WAY VOICE COMMUNICATION
- 84 26. SYSTEM INFORMATION. INFO SMS
- 84 26.1. Periodic Info SMS
- 86 27. SYSTEM NOTIFICATIONS
- 89 27.1. SMSC (Short Message Service Center) Phone Number
- 90 28. EVENT LOG
- 91 29. INDICATION OF SYSTEM FAULTS
- 93 30. MONITORING STATION
- 94 30.1. Data Messages – Events
- 98 30.2. Communication
- 108 31. ELDES WIRED DEVICES
- 108 31.1. RS485 Interface
- 121 31.2. 1-Wire Interface
- 121 31.3. Modules Interface
- 126 32. ELDES WIRELESS DEVICES
- 126 32.1. EWT1 - Wireless Transmitter-Receiver
- 127 32.2. EW1 - Wireless Zone & PGM Output Expansion Module
- 129 32.3. EWP1 – Wireless Motion Detector
- 131 32.4. EWD1 – Wireless Magnetic Door Contact
- 133 32.5. EWK1 - Wireless Keyfob
- 135 32.6. EWS1 – Wireless Indoor Siren
- 137 32.7. EWS2 – Wireless Outdoor Siren
- 140 32.8. EW1B - Battery-Powered Wireless Zone & PGM Output Expansion Module
- 143 32.9. EWF1 - Wireless Smoke Detector
- 148 32.10. EWK2 - Wireless Keyfob
- 151 32.11. EWD2 - Wireless Door Contact/Shock Sensor/Water Sensor
- 155 32.12. EWS3 - Wireless Indoor Siren
- 159 33. REMOTE SYSTEM RESTART
- 160 34. TECHNICAL SUPPORT
- 160 34.1. Troubleshooting
- 160 34.2. Restoring Default Parameters
- 160 34.3. Updating the Firmware via USB Cable Locally
- 161 34.4. Updating Firmware via GPRS Connection Remotely
- 162 34.5. Frequently Asked Questions
- 164 35. RELATED PRODUCTS