1. GENERAL INFORMATION. Eldes EKB3

Add to My manuals
168 Pages

advertisement

1. GENERAL INFORMATION. Eldes EKB3 | Manualzz

1. GENERAL INFORMATION

1.1. Functionality

ESIM264 – micro-controller based alarm system for houses, cottages, country homes, garages and other buildings, also capable of managing electrical appliances via cellular GSM/GPRS network. It can also be used as Intercom system.

Examples of using the system:

• Property security.

• Alarm switch.

• Thermostat, heating and air-conditioner control, temperature monitoring.

• Lighting, garden watering, water pump and other electrical equipment control via SMS text messages.

• Remote listening to what is happening in the secured area.

• Main 230V power status with SMS text message.

• Two-way intercom device via GSM network.

1.2. Compatible Device Overview

EKB2

EKB3

EA1

EA2

Device

EPGM1

EPGM8

Wired Devices

Description

LCD keypad

LED keypad

Audio output module with 3,5mm jack

Audio amplifier module 1W 8Ω

16 zone and 2 PGM output expansion module

8 PGM output expansion module

4*

Max. Connectable Devices

4*

1**

1**

1

1**

EW1

Device

EW1B

EWP1

EWD1

EWD2

EWK1****

EWK2****

EWS1

EWS2

EWS3

EWF1

Wireless Devices

Description

Wireless 2 zone and 2 PGM output expansion module

Battery-powered wireless 2 zone and 2 PGM output expansion module

Wireless motion detector

Wireless magnetic door contact

Wireless magnetic door contact/shock sensor/water sensor

Wireless keyfob with 4 buttons

Wireless keyfob with 4 buttons

Wireless indoor siren

Wireless outdoor siren

Wireless indoor siren

Wireless smoke detector

Max. Connectable Devices

16***

16***

16***

16***

16***

5***

5***

16***

16***

16***

16***

* - A mixed combination of EKB2 and EKB3 keypads is supported. The combination can consist of up to 4 keypads in total.

** - Only 1 of these modules can be connected at a time if the module slots are implemented in ESIM264 unit.

*** - A mixed combination of wireless devices is supported. The combination can consist of up to 32 wireless devices in total.

**** - A mixed combination of EWK1 and EWK2 keyfobs is supported. The combination can consist of up to 5 keyfobs in total.

1.3. Default Parameters & Ways of Parameter Configuration

Main Settings

Parameter Default Value

SMS & EKB2 Menu Language

SMS Password

User Password 1

User Password 2... 30

Administrator Password

Duress Password

SGS Password

Depends on firmware version according to user‘s location

0000

1111

N/A

1470

N/A

N/A

User 1... 5 Phone Number N/A

Allow Control from Any Phone Number Disabled

Date & Time

Exit Delay - Partition 1... 4

Info SMS Scheduler

N/A

15 seconds

Frequency (days) – 1; Time - 11

Configurable by:

SMS EKB2 EKB3

Configuration

Tool

66 EN MANUAL ELDES ESIM264 V3.1

Zones

Parameter Default Value

Zone Name

Entry Delay

On-Board Zone Delay

EPGM1 Zone Delay

On-board Z1 Zone Type

On-board Z2... Z12 Zone Type

Keypad Zone Type

EPGM1 Zone Type

Z1 - Zone 1; Z2 - Zone 2; Z3 - Zone 3; Z4 - Zone 4; Z5 -

Zone 5; Z6 - Zone 6

15 seconds

800 milliseconds

800 milliseconds

Delay

Instant

Instant

Instant

Wireless Zone Type

Virtual Zone Type

Depends on the connected wireless device

Interior Follower

ATZ Mode Disabled

6-Zone Mode: Zone Connection Type Type 1

ATZ Mode: Zone Connection Type

On-board Zone Status

Keypad Zone Status

EPGM1 Zone Status

Type 4

Enabled

Disabled

Enabled

Wireless Zone Status

Virtual Zone Status

Stay attribute for individual zone

Arm-Disarm by Zone

Force atrribute for individual zone

Tamper Name

Chime

Depends on the connected wireless device

Disabled

Disabled

N/A

Disabled

Tamper 1, Tamper 2, Tamper 3, Tamper 4, Tamper 5,

Tamper 6 etc.

Enabled

Configurable by:

SMS EKB2 EKB3

PGM Outputs

Parameter Default Value

PGM Output Name

PGM Output Status

EPGM8 PGM Output Status

EPGM1 PGM Output Status

Wireless PGM Output Status

Wireless PGM Output Type

PGM Output Control by Event 1... 16

PGM Output Control by Event Management

Scheduler 1... 16

Turn ON/OFF PGM Output by Timer

Using Module EPGM8 Mode

C1 – Controll1, C2 – Controll2, C3 – Controll3, C4 – Controll4 etc.

Disabled

Disabled

Disabled

Enabled

Depends on the connected wireless device

Disabled

Disabled

Disabled

Configurable by:

SMS EKB2 EKB3

Parameter Default Value

Alarm Duration

EWS2 LED

1 minute

Disabled

Bell Squawk Disabled

Activate Siren if Wireless Device is Lost Disabled

Alarm Duration & Siren

Configurable by:

SMS EKB2 EKB3

 

Configuration

Tool

Configuration

Tool

Configuration

Tool

MANUAL ELDES ESIM264 V3.1

EN 77

Parameter

Alarm Notifications & Arm/Disarm Notifications

Configurable by:

Default Value

SMS EKB2 EKB3

Call in Case of Alarm

Send Alarm SMS to All Users Simultaneously

Enabled

Disabled

Send Arm/Disarm SMS to User 1... 5 Enabled

Send Arm/Disarm SMS to All Selected

Users Simultaneously

Disabled

Main Power Status

Parameter

Main Power Loss Delay

Main Power Restore Delay

Default Value

30 seconds

120 seconds

Configurable by:

SMS EKB2 EKB3

Peripheral Devices

Parameter

Temperature Sensor MIN

Temperature Sensor MAX

Allow adding New iButton Keys

Default Value

0 °C

0 °C

Disabled

Configurable by:

SMS EKB2 EKB3

System Notifications

Parameter

General Alarm

System Disarmed

System Armed

Parameter

Enabled

Enabled

Enabled

Main Power Loss Event Enabled Enabled

Main Power Restore Event Enabled Enabled

Low Battery

Periodical Info

Enabled

Enabled

Tamper Alarm Event

Battery Failed

System Started

Wireless Signal Loss

Enabled

Enabled

Enabled

Enabled

Temperature Fallen

Temperature Exceeded

System Shutdown

Enabled

Enabled

Enabled

Configurable by:

SMS EKB2 EKB3

Partitions

Parameter

Partition 0 Name

Partition 1 Name

Default Value

PART0

PART1

Configurable by:

SMS EKB2 EKB3

Configuration

Tool

Configuration

Tool

Configuration

Tool

Configuration

Tool

Configuration

Tool

88 EN MANUAL ELDES ESIM264 V3.1

Partitions

Parameter

Keypad 1... 4 Partition

Keypad Partition Switch

User Password 1... 30 Partition

User 1... 5 Phone Number Partition iButton 1... 5 Partition

Zone Partition

Default Value

PART0

Disabled

PART0

PART0

PART0

PART0

Parameter Default Value

MS Mode

Data Messages

Account (Alarm System ID)

Monitoring Station Phone Number 1... 3

(Voice Calls/SMS)

Attempts (Voice Calls/SMS)

Monitoring Station Phone Number 1...

5 (CSD)

Attempts (CSD)

Server IP Address (GPRS)

DNS1 Server IP Address (GPRS)

DNS2 Server IP Address (GPRS)

Protocol (GPRS)

Server Port (GPRS)

Local Port (GPRS)

APN (GPRS)

User (GPRS)

Password (GPRS)

Profile (GPRS)

GPRS Attempts

Delay Between Attempts (GPRS)

Unit ID (GPRS)

Test Period (GPRS)

Communication - Primary

Communication - Backup 1... 4

Protocol over GPRS

Disabled

All Enabled

9999

N/A

3

N/A

3

0.0.0.0

N/A

N/A

UDP

20000

N/A

N/A

N/A

N/A

Profile1

3

600 seconds

0000

180 seconds

N/A

N/A

EGR100

Monitoring Station

Configurable by:

SMS EKB2 EKB3

Configuration

Tool

Configurable by:

SMS EKB2 EKB3

 

Configuration

Tool

MANUAL ELDES ESIM264 V3.1

EN 99

Parameter Default Value

Event Log

Microphone Gain

Speaker Level

GSM Signal Loss Indication - Delay

Enabled

12

85

180 seconds

GSM Signal Loss Indication - Activate

Output

N/A

Show ARMED Status in Keypad (EKB2) Disabled

Additional Parameters

Parameter

ELDES Smart Security

Server Address

Port

Ping Period

Time Zone

Default Value

ELDES Smart Security

Disabled ss.eldes.lt

8082

180 seconds

0

Configurable by:

SMS EKB2 EKB3

Configuration

Tool

Configurable by:

SMS EKB2 EKB3

Configuration

Tool

10 EN MANUAL ELDES ESIM264 V3.1

MANUAL ELDES ESIM264 V3.1

EN

advertisement

Related manuals

advertisement

Table of contents