19.2. Wireless Device Information and Signal Status Monitoring. Eldes EKB3
Add to My manuals168 Pages
advertisement
![19.2. Wireless Device Information and Signal Status Monitoring. Eldes EKB3 | Manualzz 19.2. Wireless Device Information and Signal Status Monitoring. Eldes EKB3 | Manualzz](http://s1.manualzz.com/store/data/001731187_1-63f6db8abae8ee33f0d3ba1fa4d45eb5-360x466.png)
ATTENTION: In order to correctly remove the wireless device from the system, the user must remove the device using SMS text message or ELDES Configuration Tool software and restore the parameters of the wireless device to default afterwards. If only one of these actions is carried out, the wireless device and the system will attempt to exchange data to keep the wireless connection alive. This leads to fast battery power drain on the battery-powered wireless device.
19.2. Wireless Device Information and Signal Status Monitoring
Once a wireless device is bound, the user can view the following information of a determined wireless device:
• Battery level (expressed in percentage).
• Wireless signal strength (expressed in percentage).
• Error rate (number of failed data transmission attempts in 10-minute period).
• Firmware version.
To view the wireless device information, please refer to the following configuration methods.
View wireless device information
SMS
EKB2
SMS text message content: ssss_RFINFO:wless-id or ssss_RFINFO:Znn
Value: wless-id – 8-digit wireless device ID code; nn – wireless zone number, range – [13...
76].
Example: 1111_RFINFO:535185D
Menu path:
Battery level: OK → CONFIGURATION → OK → aaaa → OK → WIRELESS DEVICES → OK → wless-dev wless-id → OK → BATTERY
Wireless signal: OK → CONFIGURATION → OK → aaaa → OK → WIRELESS DEVICES → OK → wless-dev wless-id → OK → SIGNAL
Error rate: OK → CONFIGURATION → OK → aaaa → OK → WIRELESS DEVICES → OK → wlessdev wless-id → OK → ERROR RATE
Firmware version: OK → CONFIGURATION → OK → aaaa → OK → WIRELESS DEVICES → OK → wless-dev wless-id → OK → FW RELEASE
Value: aaaa – 4-digit administrator password; wless-dev – wireless device model; wless-id
– 8-digit wireless device ID code.
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
The system supports up to 16 wireless devices. To view the number of unoccupied wireless device slots in the system, please refer to the following configuration methods
View unoccupied wireless device slots
SMS
SMS text message content: ssss_STATUS_FREE
Example: 1111_STATUS_FREE
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
When the wireless signal between the system and a wireles device is lost and does not restore during 20 minute period, the system will send notification by SMS text message to preset user phone number. By default, the notification regarding the wireless signal status is enabled. To disable/enable this notification, please refer to 16. TAMPERS.
MANUAL ELDES ESIM264 V3.1
EN
advertisement
Related manuals
advertisement
Table of contents
- 6 1. GENERAL INFORMATION
- 6 1.1. Functionality
- 6 1.2. Compatible Device Overview
- 6 1.3. Default Parameters & Ways of Parameter Configuration
- 12 2. Technical Specifications
- 12 2.1. Electrical & Mechanical Characteristics
- 13 2.2. Main Unit, LED & Connector Functionality
- 14 2.3. Wiring Diagrams
- 20 3. INSTALLATION
- 24 4. GENERAL OPERATIONAL DESCRIPTION
- 25 5. CONFIGURATION METHODS
- 28 6. PASSWORDS
- 29 7. SYSTEM LANGUAGE
- 30 8. USER PHONE NUMBERS
- 31 8.1. System Control from any Phone Number
- 33 9. DATE AND TIME
- 34 10. USER PASSWORDS
- 36 11. iBUTTON KEYS
- 36 11.1. Adding and Removing iButton Keys
- 38 12. ARMING AND DISARMING
- 38 12.1. Free of Charge Phone Call
- 39 12.2. SMS Text Message
- 40 12.3. EKB2 Keypad and User Password
- 41 12.4. EKB3 Keypad and User Password
- 42 12.5. iButton Key
- 42 12.6. EWK1/EWK2 Wireless Keyfob
- 43 12.7. Arm-Disarm by Zone
- 44 12.8. Disabling and Enabling Arm/Disarm Notifications
- 46 13. EXIT AND ENTRY DELAY
- 48 14. ZONES
- 48 14.1. Zone Numbering
- 48 14.2. Zone Expansion
- 48 14.3. 6-Zone Mode
- 49 14.4. ATZ (Advanced Technology Zone) Mode
- 50 14.5. Zone Type Definitions
- 51 14.6. Zone Attributes
- 54 14.7. Bypassing and Activating Zones
- 54 14.8. Zone Names
- 55 14.9. Disabling and Enabling Zones
- 56 15. STAY MODE
- 57 16. TAMPERS
- 57 16.1. Tamper Names
- 58 17. ALARM INDICATIONS AND NOTIFICATIONS
- 59 17.1. Enabling and Disabling Alarm Notifications
- 62 18. PROGRAMMABLE (PGM) OUTPUTS
- 62 18.1. PGM Output Numbering
- 62 18.2. PGM Output Expansion
- 63 18.3. PGM Output Names
- 63 18.4. Turning PGM Outputs ON and OFF
- 65 18.5. PGM Output Control by Event and Scheduler
- 66 18.6. Wireless PGM Output Type Definitions
- 67 19. WIRELESS DEVICES
- 67 19.1. Binding, Removing and Replacing Wireless Devicess
- 69 19.2. Wireless Device Information and Signal Status Monitoring
- 70 19.3. Disabling and Enabling Siren if Wireless Signal is Lost
- 71 20. SIREN/BELL
- 72 20.1. Bell Squawk
- 72 20.2. Indication by EWS2 Indicators
- 73 20.3. EWF1 Interconnection
- 74 21. BACKUP BATTERY, MAINS POWER SUPPLY STATUS MONITORING AND MEMORY
- 77 22. GSM CONNECTION STATUS MONITORING
- 78 23. PARTITIONS
- 78 23.1. Zone Partition
- 78 23.2. User Phone Number Partition
- 79 23.3. Keypad Partition and Keypad Partition Switch
- 80 23.4. User Password Partition
- 80 23.5. iButton Key Partition
- 80 23.6. EWK1/EWK2 Wireless Keyfob Partition
- 81 24. TEMPERATURE SENSORS
- 81 24.1. Adding, Removing and Replacing Temperature Sensors
- 81 24.2. Setting Up MIN and MAX Temperature Boundaries. Temperature Info SMS
- 83 25. REMOTE LISTENING AND 2-WAY VOICE COMMUNICATION
- 84 26. SYSTEM INFORMATION. INFO SMS
- 84 26.1. Periodic Info SMS
- 86 27. SYSTEM NOTIFICATIONS
- 89 27.1. SMSC (Short Message Service Center) Phone Number
- 90 28. EVENT LOG
- 91 29. INDICATION OF SYSTEM FAULTS
- 93 30. MONITORING STATION
- 94 30.1. Data Messages – Events
- 98 30.2. Communication
- 108 31. ELDES WIRED DEVICES
- 108 31.1. RS485 Interface
- 121 31.2. 1-Wire Interface
- 121 31.3. Modules Interface
- 126 32. ELDES WIRELESS DEVICES
- 126 32.1. EWT1 - Wireless Transmitter-Receiver
- 127 32.2. EW1 - Wireless Zone & PGM Output Expansion Module
- 129 32.3. EWP1 – Wireless Motion Detector
- 131 32.4. EWD1 – Wireless Magnetic Door Contact
- 133 32.5. EWK1 - Wireless Keyfob
- 135 32.6. EWS1 – Wireless Indoor Siren
- 137 32.7. EWS2 – Wireless Outdoor Siren
- 140 32.8. EW1B - Battery-Powered Wireless Zone & PGM Output Expansion Module
- 143 32.9. EWF1 - Wireless Smoke Detector
- 148 32.10. EWK2 - Wireless Keyfob
- 151 32.11. EWD2 - Wireless Door Contact/Shock Sensor/Water Sensor
- 155 32.12. EWS3 - Wireless Indoor Siren
- 159 33. REMOTE SYSTEM RESTART
- 160 34. TECHNICAL SUPPORT
- 160 34.1. Troubleshooting
- 160 34.2. Restoring Default Parameters
- 160 34.3. Updating the Firmware via USB Cable Locally
- 161 34.4. Updating Firmware via GPRS Connection Remotely
- 162 34.5. Frequently Asked Questions
- 164 35. RELATED PRODUCTS