12.7. Arm-Disarm by Zone

ARM/

DISARM

ZONE

The Arm-Disarm by Zone feature allows to use a zone for arming and disarming the alarm system when the zone is violated and restored. The process is performed by providing a low-level pulse for more than 3 seconds into the specified zone. It means that violating and restoring the zone leads to system arming and by repeating this action the system becomes disarmed. The system will arm/disarm the partition (-s) that the zone is assigned to. This method can be set up for one on-board zone only.

Set zone for Arm-

Disarm by Zone method

EKB2

EKB3

Menu path:

OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → ARM/DISARM BY ZONE

→ OK → ZONE 1... 12 → OK

Value: aaaa – 4-digit administrator password.

Enter parameter 34 & on-board zone number:

34 nn #

Value: nn – on-board zone number, range – [01... 12].

Example: 3403#

Config

Tool

This operation may be carried out from the PC using the ELDES Configuration Tool software.

Disable Arm-Disarm by

Zone method

EKB2

EKB3

Menu path:

OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → ARM/DISARM BY ZONE

→ OK → N/A → OK

Value: aaaa – 4-digit administrator password.

Enter parameter 34 & parameter status value

34 00 #

Example: 3400#

Config

Tool

This operation may be carried out from the PC using the ELDES Configuration Tool software.