This operation may be carried out from the PC using the ELDES Configuration Tool software.
NOTE: The system will NOT activate siren/bell and keypad buzzer only when Panic/Silent zone type is violated.
14.6. Zone Attributes
• Stay – If this attribute is enabled, the zone, regardless of type, will not cause an alarm if violated when the system is Stay armed. For more details on arming the system in the Stay mode, please refer to 15. STAY MODE.
• Force – This attribute determines whether the system can be armed or not while a zone is violated. If a zone with the Force attribute enabled is left violated until the exit delay expires, it will be ignored. Once the system is armed and the zone is restored, the violation will not be ignored and the zone will operate according to the determined type. For more details on zone types, please refer to 14.5.
Zone Type Definitions.
• Delay, ms – This attribute determines the zone sensitivity level by delay time (By default – 800 milliseconds). If a zone is left triggered until the delay time expires, the zone is considered violated.
• Delay becomes Instant in Stay mode – This attribute determines whether or not any Delay type zone will operate as Instant type zone when the system is armed in the Stay mode. When the system is fully armed, the Delay type zone will operate normally. For more details on Delay and Instant zone types, please refer to 14.5. Zone Type Definitions.
• Chime – This feature is used to emit 3 short beeps from the keypad buzzer and display icon on EKB2 keypad screen whenever any
Delay type zone is violated. Typically, the feature is used for designated exit/entry doors to indicate the opening of the doors.
• Alarm count to bypass – This attribute determines a number of times the zone can be violated until it is automatically bypassed.
For more details on zone bypassing and how to activate a bypassed zone, please refer to 14.7. Bypassing and Activating Zones.
Enable Stay attribute for individual zone
EKB2
EKB3
Menu path:
On-board zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → ONBOARD
ZONES → OK → ZONE 1... 12 → OK → STAY → OK → ENABLE → OK
Wireless zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → WIRELESS
ZONES → OK → WLESS ZONE 1... 16 → OK → STAY → OK → ENABLE → OK
Keypad zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → KEYPAD
ZONES → OK → KEYPAD 1... 4 ZONE → OK → STAY → OK → ENABLE → OK
EPGM1 zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → EPGM1 ZONES →
OK → EPGM1 ZONE 1... 16 → OK → STAY → OK → ENABLE → OK
Value: aaaa – 4-digit administrator password.
Enter parameter 56, zone number & parameter status value:
56 nn 1 #
Value: nn – zone number, range – [01... 44].
Example: 56041#
MANUAL ELDES ESIM264 V3.1
EN
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
Disable Stay attribute for individual zone
EKB2
EKB3
Menu path:
On-board zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → ONBOARD
ZONES → OK → ZONE 1... 12 → OK → STAY → OK → DISABLE → OK
Wireless zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → WIRELESS
ZONES → OK → WLESS ZONE 1... 16 → OK → STAY → OK → DISABLE → OK
Keypad zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → KEYPAD
ZONES → OK → KEYPAD 1... 4 ZONE → OK → STAY → OK → DISABLE → OK
EPGM1 zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → EPGM1
ZONES → OK → EPGM1 ZONE 1... 16 → OK → STAY → OK → DISABLE → OK
Value: aaaa – 4-digit administrator password.
Enter parameter 56, zone number & parameter status value:
56 nn 0 #
Value: nn – zone number, range – [01... 44].
Example: 56190#
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
Enable Force attribute for individual zone
EKB2
EKB3
Menu path:
On-board zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → ONBOARD
ZONES → OK → ZONE 1... 12 → OK → FORCE → OK → ENABLE → OK
Wireless zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → WIRELESS
ZONES → OK → WLESS ZONE 1... 16 → OK → FORCE → OK → ENABLE → OK
Keypad zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → KEYPAD ZONES
→ OK → KEYPAD 1... 4 ZONE → OK → FORCE → OK → ENABLE → OK
EPGM1 zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → EPGM1 ZONES →
OK → EPGM1 ZONE 1... 16 → OK → FORCE → OK → ENABLE → OK
Value: aaaa – 4-digit administrator password.
Enter parameter 82, zone number & parameter status value:
82 nn 1 #
Value: nn – zone number, range – [01... 44].
Example: 82061#
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
Disable Force attribute for individual zone
EKB2
EKB3
Menu path:
On-board zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → ONBOARD
ZONES → OK → ZONE 1... 12 → OK → FORCE → OK → DISABLE → OK
Wireless zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → WIRELESS
ZONES → OK → WLESS ZONE 1... 16 → OK → FORCE → OK → DISABLE → OK
Keypad zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → KEYPAD
ZONES → OK → KEYPAD 1... 4 ZONE → OK → FORCE → OK → DISABLE → OK
EPGM1 zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → EPGM1 ZONES→
OK → EPGM1 ZONE 1... 16 → OK → STAY → OK → DISABLE → OK
Value: aaaa – 4-digit administrator password.
Enter parameter 82, zone number & parameter status value:
82 nn 0 #
Value: nn – zone number, range – [01... 44].
Example: 82110#
52 EN MANUAL ELDES ESIM264 V3.1
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
Set Delay, ms atrribute
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
Enable/disable Delay becomes Instant in
Stay mode attribute
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
Disable Chime attribute
EKB2
Menu path:
OK → CONFIGURATION → OK →aaaa → OK → ZONES → OK → CHIME → OK → DISABLE → OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 32 & parameter status value:
32 0 #
Example: 320#
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
Enable Chime attribute
EKB2
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → CHIME → OK → ENABLE → OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 32 & parameter status value:
32 1 #
Example: 321#
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
Set Alarm count to bypass attribute for individual zone
Config
Tool This operation may be carried out from the PC using the ELDES Configuration Tool software.
MANUAL ELDES ESIM264 V3.1
EN
advertisement
Related manuals
advertisement
Table of contents
- 6 1. GENERAL INFORMATION
- 6 1.1. Functionality
- 6 1.2. Compatible Device Overview
- 6 1.3. Default Parameters & Ways of Parameter Configuration
- 12 2. Technical Specifications
- 12 2.1. Electrical & Mechanical Characteristics
- 13 2.2. Main Unit, LED & Connector Functionality
- 14 2.3. Wiring Diagrams
- 20 3. INSTALLATION
- 24 4. GENERAL OPERATIONAL DESCRIPTION
- 25 5. CONFIGURATION METHODS
- 28 6. PASSWORDS
- 29 7. SYSTEM LANGUAGE
- 30 8. USER PHONE NUMBERS
- 31 8.1. System Control from any Phone Number
- 33 9. DATE AND TIME
- 34 10. USER PASSWORDS
- 36 11. iBUTTON KEYS
- 36 11.1. Adding and Removing iButton Keys
- 38 12. ARMING AND DISARMING
- 38 12.1. Free of Charge Phone Call
- 39 12.2. SMS Text Message
- 40 12.3. EKB2 Keypad and User Password
- 41 12.4. EKB3 Keypad and User Password
- 42 12.5. iButton Key
- 42 12.6. EWK1/EWK2 Wireless Keyfob
- 43 12.7. Arm-Disarm by Zone
- 44 12.8. Disabling and Enabling Arm/Disarm Notifications
- 46 13. EXIT AND ENTRY DELAY
- 48 14. ZONES
- 48 14.1. Zone Numbering
- 48 14.2. Zone Expansion
- 48 14.3. 6-Zone Mode
- 49 14.4. ATZ (Advanced Technology Zone) Mode
- 50 14.5. Zone Type Definitions
- 51 14.6. Zone Attributes
- 54 14.7. Bypassing and Activating Zones
- 54 14.8. Zone Names
- 55 14.9. Disabling and Enabling Zones
- 56 15. STAY MODE
- 57 16. TAMPERS
- 57 16.1. Tamper Names
- 58 17. ALARM INDICATIONS AND NOTIFICATIONS
- 59 17.1. Enabling and Disabling Alarm Notifications
- 62 18. PROGRAMMABLE (PGM) OUTPUTS
- 62 18.1. PGM Output Numbering
- 62 18.2. PGM Output Expansion
- 63 18.3. PGM Output Names
- 63 18.4. Turning PGM Outputs ON and OFF
- 65 18.5. PGM Output Control by Event and Scheduler
- 66 18.6. Wireless PGM Output Type Definitions
- 67 19. WIRELESS DEVICES
- 67 19.1. Binding, Removing and Replacing Wireless Devicess
- 69 19.2. Wireless Device Information and Signal Status Monitoring
- 70 19.3. Disabling and Enabling Siren if Wireless Signal is Lost
- 71 20. SIREN/BELL
- 72 20.1. Bell Squawk
- 72 20.2. Indication by EWS2 Indicators
- 73 20.3. EWF1 Interconnection
- 74 21. BACKUP BATTERY, MAINS POWER SUPPLY STATUS MONITORING AND MEMORY
- 77 22. GSM CONNECTION STATUS MONITORING
- 78 23. PARTITIONS
- 78 23.1. Zone Partition
- 78 23.2. User Phone Number Partition
- 79 23.3. Keypad Partition and Keypad Partition Switch
- 80 23.4. User Password Partition
- 80 23.5. iButton Key Partition
- 80 23.6. EWK1/EWK2 Wireless Keyfob Partition
- 81 24. TEMPERATURE SENSORS
- 81 24.1. Adding, Removing and Replacing Temperature Sensors
- 81 24.2. Setting Up MIN and MAX Temperature Boundaries. Temperature Info SMS
- 83 25. REMOTE LISTENING AND 2-WAY VOICE COMMUNICATION
- 84 26. SYSTEM INFORMATION. INFO SMS
- 84 26.1. Periodic Info SMS
- 86 27. SYSTEM NOTIFICATIONS
- 89 27.1. SMSC (Short Message Service Center) Phone Number
- 90 28. EVENT LOG
- 91 29. INDICATION OF SYSTEM FAULTS
- 93 30. MONITORING STATION
- 94 30.1. Data Messages – Events
- 98 30.2. Communication
- 108 31. ELDES WIRED DEVICES
- 108 31.1. RS485 Interface
- 121 31.2. 1-Wire Interface
- 121 31.3. Modules Interface
- 126 32. ELDES WIRELESS DEVICES
- 126 32.1. EWT1 - Wireless Transmitter-Receiver
- 127 32.2. EW1 - Wireless Zone & PGM Output Expansion Module
- 129 32.3. EWP1 – Wireless Motion Detector
- 131 32.4. EWD1 – Wireless Magnetic Door Contact
- 133 32.5. EWK1 - Wireless Keyfob
- 135 32.6. EWS1 – Wireless Indoor Siren
- 137 32.7. EWS2 – Wireless Outdoor Siren
- 140 32.8. EW1B - Battery-Powered Wireless Zone & PGM Output Expansion Module
- 143 32.9. EWF1 - Wireless Smoke Detector
- 148 32.10. EWK2 - Wireless Keyfob
- 151 32.11. EWD2 - Wireless Door Contact/Shock Sensor/Water Sensor
- 155 32.12. EWS3 - Wireless Indoor Siren
- 159 33. REMOTE SYSTEM RESTART
- 160 34. TECHNICAL SUPPORT
- 160 34.1. Troubleshooting
- 160 34.2. Restoring Default Parameters
- 160 34.3. Updating the Firmware via USB Cable Locally
- 161 34.4. Updating Firmware via GPRS Connection Remotely
- 162 34.5. Frequently Asked Questions
- 164 35. RELATED PRODUCTS