20. SIREN/BELL
When the system is in alarm state, the siren/bell will sound until the set time (By default – 1 minute) expires or until the system is disarmed.
To set the alarm duration, please refer to the following configuration methods.
Set alarm duration SMS
EKB2
EKB3
SMS text message content: ssss_SIREN:t
Value: ssss – 4-digit SMS password; t – alarm duration, range – [0... 5] minutes.
Example: 1111_SIREN:4
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → PRIMARY SETT INGS → OK → SIREN SETTINGS
→ OK → ALARM DURATION → OK → tt → OK
Value: aaaa – 4-digit administrator password; tt – alarm duration, range – [1... 10] minutes.
Enter parameter 10 & alarm duration:
10 tt #
Value: tt – alarm duration, range – [00... 10] minutes.
Example: 1007#
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
View alarm duration
SMS
EKB2
SMS text message content: ssss_SIREN
Value: ssss – 4-digit SMS password
Example: 1111_SIREN
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → PRIMARY SETT INGS → OK → SIREN SETTINGS
→ OK → ALARM DURATION
Value: aaaa – 4-digit administrator password.
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
For siren/bell wiring diagram, please refer to 2.3.3. Siren.
NOTE: 0 value disables the siren/bell.
NOTE: Due to battery power saving reasons, the wireless siren will sound for 1 minute regardless of the set alarm duration time, unless it is set to 0.
MANUAL ELDES ESIM264 V3.1
EN
advertisement
Related manuals
advertisement
Table of contents
- 6 1. GENERAL INFORMATION
- 6 1.1. Functionality
- 6 1.2. Compatible Device Overview
- 6 1.3. Default Parameters & Ways of Parameter Configuration
- 12 2. Technical Specifications
- 12 2.1. Electrical & Mechanical Characteristics
- 13 2.2. Main Unit, LED & Connector Functionality
- 14 2.3. Wiring Diagrams
- 20 3. INSTALLATION
- 24 4. GENERAL OPERATIONAL DESCRIPTION
- 25 5. CONFIGURATION METHODS
- 28 6. PASSWORDS
- 29 7. SYSTEM LANGUAGE
- 30 8. USER PHONE NUMBERS
- 31 8.1. System Control from any Phone Number
- 33 9. DATE AND TIME
- 34 10. USER PASSWORDS
- 36 11. iBUTTON KEYS
- 36 11.1. Adding and Removing iButton Keys
- 38 12. ARMING AND DISARMING
- 38 12.1. Free of Charge Phone Call
- 39 12.2. SMS Text Message
- 40 12.3. EKB2 Keypad and User Password
- 41 12.4. EKB3 Keypad and User Password
- 42 12.5. iButton Key
- 42 12.6. EWK1/EWK2 Wireless Keyfob
- 43 12.7. Arm-Disarm by Zone
- 44 12.8. Disabling and Enabling Arm/Disarm Notifications
- 46 13. EXIT AND ENTRY DELAY
- 48 14. ZONES
- 48 14.1. Zone Numbering
- 48 14.2. Zone Expansion
- 48 14.3. 6-Zone Mode
- 49 14.4. ATZ (Advanced Technology Zone) Mode
- 50 14.5. Zone Type Definitions
- 51 14.6. Zone Attributes
- 54 14.7. Bypassing and Activating Zones
- 54 14.8. Zone Names
- 55 14.9. Disabling and Enabling Zones
- 56 15. STAY MODE
- 57 16. TAMPERS
- 57 16.1. Tamper Names
- 58 17. ALARM INDICATIONS AND NOTIFICATIONS
- 59 17.1. Enabling and Disabling Alarm Notifications
- 62 18. PROGRAMMABLE (PGM) OUTPUTS
- 62 18.1. PGM Output Numbering
- 62 18.2. PGM Output Expansion
- 63 18.3. PGM Output Names
- 63 18.4. Turning PGM Outputs ON and OFF
- 65 18.5. PGM Output Control by Event and Scheduler
- 66 18.6. Wireless PGM Output Type Definitions
- 67 19. WIRELESS DEVICES
- 67 19.1. Binding, Removing and Replacing Wireless Devicess
- 69 19.2. Wireless Device Information and Signal Status Monitoring
- 70 19.3. Disabling and Enabling Siren if Wireless Signal is Lost
- 71 20. SIREN/BELL
- 72 20.1. Bell Squawk
- 72 20.2. Indication by EWS2 Indicators
- 73 20.3. EWF1 Interconnection
- 74 21. BACKUP BATTERY, MAINS POWER SUPPLY STATUS MONITORING AND MEMORY
- 77 22. GSM CONNECTION STATUS MONITORING
- 78 23. PARTITIONS
- 78 23.1. Zone Partition
- 78 23.2. User Phone Number Partition
- 79 23.3. Keypad Partition and Keypad Partition Switch
- 80 23.4. User Password Partition
- 80 23.5. iButton Key Partition
- 80 23.6. EWK1/EWK2 Wireless Keyfob Partition
- 81 24. TEMPERATURE SENSORS
- 81 24.1. Adding, Removing and Replacing Temperature Sensors
- 81 24.2. Setting Up MIN and MAX Temperature Boundaries. Temperature Info SMS
- 83 25. REMOTE LISTENING AND 2-WAY VOICE COMMUNICATION
- 84 26. SYSTEM INFORMATION. INFO SMS
- 84 26.1. Periodic Info SMS
- 86 27. SYSTEM NOTIFICATIONS
- 89 27.1. SMSC (Short Message Service Center) Phone Number
- 90 28. EVENT LOG
- 91 29. INDICATION OF SYSTEM FAULTS
- 93 30. MONITORING STATION
- 94 30.1. Data Messages – Events
- 98 30.2. Communication
- 108 31. ELDES WIRED DEVICES
- 108 31.1. RS485 Interface
- 121 31.2. 1-Wire Interface
- 121 31.3. Modules Interface
- 126 32. ELDES WIRELESS DEVICES
- 126 32.1. EWT1 - Wireless Transmitter-Receiver
- 127 32.2. EW1 - Wireless Zone & PGM Output Expansion Module
- 129 32.3. EWP1 – Wireless Motion Detector
- 131 32.4. EWD1 – Wireless Magnetic Door Contact
- 133 32.5. EWK1 - Wireless Keyfob
- 135 32.6. EWS1 – Wireless Indoor Siren
- 137 32.7. EWS2 – Wireless Outdoor Siren
- 140 32.8. EW1B - Battery-Powered Wireless Zone & PGM Output Expansion Module
- 143 32.9. EWF1 - Wireless Smoke Detector
- 148 32.10. EWK2 - Wireless Keyfob
- 151 32.11. EWD2 - Wireless Door Contact/Shock Sensor/Water Sensor
- 155 32.12. EWS3 - Wireless Indoor Siren
- 159 33. REMOTE SYSTEM RESTART
- 160 34. TECHNICAL SUPPORT
- 160 34.1. Troubleshooting
- 160 34.2. Restoring Default Parameters
- 160 34.3. Updating the Firmware via USB Cable Locally
- 161 34.4. Updating Firmware via GPRS Connection Remotely
- 162 34.5. Frequently Asked Questions
- 164 35. RELATED PRODUCTS