14.5. Zone Type Definitions. Eldes EKB3

Add to My manuals
168 Pages

advertisement

14.5.  Zone Type Definitions. Eldes EKB3 | Manualzz

Set zone connection type for ATZ mode

EKB2

Menu path:

OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → ZONE TYPE:ATZ MODE →

OK → TYPE 4... 5 → OK

Value: aaaa – 4-digit administrator password.

EKB3

Enter parameter 38 & number of zone connection type:

38 1 # – Type 4

38 2 # – Type 5

Example: 381#

Config

Tool

This operation may be carried out from the PC using the ELDES Configuration Tool software.

NOTE: The ATZ mode applies to on-board zones only when enabled.

14.5. Zone Type Definitions

• Interior Follower – The zone can be violated during exit and entry delay without causing an alarm. If the zone is violated before the entry delay has begun, it will cause an instant alarm followed by single notification delivery even if the zone has been violated multiple times or another Interior Follower-type zone has been violated while alarm period (by default - 1 minute) is in progress. The zone is used where violating a zone during exit/entry delay is unavoidable. Typically, this zone is used for indoor protection devices, such as motion detectors, installed close to the exit/entry doors.

• Instant – The alarm is instantly caused if this zone is violated when the system is armed or during entry delay. This zone type is usually used for doors, windows or other zones, and shock detectors.

• 24-Hour – When the system is either armed or disarmed, the zone will cause instant alarm if violated. Normally, this type of zone is used for securing the areas that require constant supervisory.

• Delay – This zone type can be violated during exit and entry delay without causing an alarm. If the zone is violated when the system is armed, it will initiate entry delay countdown intended for the user to disarm the system. If the zone is left violated after the exit delay expires, it will cause an instant alarm. If one more zone with Stay-enabled attribute exist and the Delay-type zone is not violated and restored during exit delay, the system will be armed in Stay mode (see 15. STAY MODE). Typically, this zone type is used for door contacts installed at designated exit/entry doors.

• Fire – If this zone type is violated when the system is either armed or disarmed, the alarm will be instantly caused and the siren/bell will emit pulsating sound. Typically, this zone type is used for flame and smoke detectors.

• Panic/Silent – This zone operates the same as 24-Hour zone type, but the system will not activate the siren/bell and keypad buzzer if violated. Normally, this zone type used for panic alarm buttons.

Set zone type for individual zone

EKB2

EKB3

Menu path:

On-board zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → ONBOARD

ZONES → OK → ZONE 1... 12 → OK → TYPE → OK → INTERIOR FOLLOWER | INSTANT | 24-

HOUR | DELAY | FIRE | PANIC/SILENT → OK

Wireless zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → WIRELESS

ZONES 1... 4 → OK → WLESS ZONE 1... 16 → OK → TYPE → OK → INTERIOR FOLLOWER |

INSTANT | 24-HOUR | DELAY | FIRE | PANIC/SILENT → OK

Keypad zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → KEYPAD ZONES

→ OK → KEYPAD 1... 4 ZONE → OK → TYPE → OK → INTERIOR FOLLOWER | INSTANT | 24-

HOUR | DELAY | FIRE | PANIC/SILENT → OK

EPGM1 zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → EPGM1 ZONES →

OK → EPGM1 ZONE 1... 16 → OK → TYPE → OK → INTERIOR FOLLOWER | INSTANT | 24-HOUR |

DELAY | FIRE | PANIC/ SILENT → OK

Value: aaaa – 4-digit administrator password.

Enter parameter 53, zone number & zone type number:

53 nn 1 # – Interior Follower

53 nn 2 # – Instant

53 nn 3 # –24-Hour

53 nn 4 # – Delay

53 nn 5 # – Fire

53 nn 6 # – Panic/Silent

Value: nn – zone number, range – [01... 44]

Example: 53125#

50 EN MANUAL ELDES ESIM264 V3.1