EKB2
Menu path:
OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → ZONE TYPE:ATZ MODE →
OK → TYPE 4... 5 → OK
Value: aaaa – 4-digit administrator password.
EKB3
Enter parameter 38 & number of zone connection type:
38 1 # – Type 4
38 2 # – Type 5
Example: 381#
Config
Tool
This operation may be carried out from the PC using the ELDES Configuration Tool software.
NOTE: The ATZ mode applies to on-board zones only when enabled.
14.5. Zone Type Definitions
• Interior Follower – The zone can be violated during exit and entry delay without causing an alarm. If the zone is violated before the entry delay has begun, it will cause an instant alarm followed by single notification delivery even if the zone has been violated multiple times or another Interior Follower-type zone has been violated while alarm period (by default - 1 minute) is in progress. The zone is used where violating a zone during exit/entry delay is unavoidable. Typically, this zone is used for indoor protection devices, such as motion detectors, installed close to the exit/entry doors.
• Instant – The alarm is instantly caused if this zone is violated when the system is armed or during entry delay. This zone type is usually used for doors, windows or other zones, and shock detectors.
• 24-Hour – When the system is either armed or disarmed, the zone will cause instant alarm if violated. Normally, this type of zone is used for securing the areas that require constant supervisory.
• Delay – This zone type can be violated during exit and entry delay without causing an alarm. If the zone is violated when the system is armed, it will initiate entry delay countdown intended for the user to disarm the system. If the zone is left violated after the exit delay expires, it will cause an instant alarm. If one more zone with Stay-enabled attribute exist and the Delay-type zone is not violated and restored during exit delay, the system will be armed in Stay mode (see 15. STAY MODE). Typically, this zone type is used for door contacts installed at designated exit/entry doors.
• Fire – If this zone type is violated when the system is either armed or disarmed, the alarm will be instantly caused and the siren/bell will emit pulsating sound. Typically, this zone type is used for flame and smoke detectors.
• Panic/Silent – This zone operates the same as 24-Hour zone type, but the system will not activate the siren/bell and keypad buzzer if violated. Normally, this zone type used for panic alarm buttons.
Set zone type for individual zone
EKB2
EKB3
Menu path:
On-board zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → ONBOARD
ZONES → OK → ZONE 1... 12 → OK → TYPE → OK → INTERIOR FOLLOWER | INSTANT | 24-
HOUR | DELAY | FIRE | PANIC/SILENT → OK
Wireless zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → WIRELESS
ZONES 1... 4 → OK → WLESS ZONE 1... 16 → OK → TYPE → OK → INTERIOR FOLLOWER |
INSTANT | 24-HOUR | DELAY | FIRE | PANIC/SILENT → OK
Keypad zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → KEYPAD ZONES
→ OK → KEYPAD 1... 4 ZONE → OK → TYPE → OK → INTERIOR FOLLOWER | INSTANT | 24-
HOUR | DELAY | FIRE | PANIC/SILENT → OK
EPGM1 zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → EPGM1 ZONES →
OK → EPGM1 ZONE 1... 16 → OK → TYPE → OK → INTERIOR FOLLOWER | INSTANT | 24-HOUR |
DELAY | FIRE | PANIC/ SILENT → OK
Value: aaaa – 4-digit administrator password.
Enter parameter 53, zone number & zone type number:
53 nn 1 # – Interior Follower
53 nn 2 # – Instant
53 nn 3 # –24-Hour
53 nn 4 # – Delay
53 nn 5 # – Fire
53 nn 6 # – Panic/Silent
Value: nn – zone number, range – [01... 44]
Example: 53125#
50 EN MANUAL ELDES ESIM264 V3.1
advertisement
Related manuals
advertisement
Table of contents
- 6 1. GENERAL INFORMATION
- 6 1.1. Functionality
- 6 1.2. Compatible Device Overview
- 6 1.3. Default Parameters & Ways of Parameter Configuration
- 12 2. Technical Specifications
- 12 2.1. Electrical & Mechanical Characteristics
- 13 2.2. Main Unit, LED & Connector Functionality
- 14 2.3. Wiring Diagrams
- 20 3. INSTALLATION
- 24 4. GENERAL OPERATIONAL DESCRIPTION
- 25 5. CONFIGURATION METHODS
- 28 6. PASSWORDS
- 29 7. SYSTEM LANGUAGE
- 30 8. USER PHONE NUMBERS
- 31 8.1. System Control from any Phone Number
- 33 9. DATE AND TIME
- 34 10. USER PASSWORDS
- 36 11. iBUTTON KEYS
- 36 11.1. Adding and Removing iButton Keys
- 38 12. ARMING AND DISARMING
- 38 12.1. Free of Charge Phone Call
- 39 12.2. SMS Text Message
- 40 12.3. EKB2 Keypad and User Password
- 41 12.4. EKB3 Keypad and User Password
- 42 12.5. iButton Key
- 42 12.6. EWK1/EWK2 Wireless Keyfob
- 43 12.7. Arm-Disarm by Zone
- 44 12.8. Disabling and Enabling Arm/Disarm Notifications
- 46 13. EXIT AND ENTRY DELAY
- 48 14. ZONES
- 48 14.1. Zone Numbering
- 48 14.2. Zone Expansion
- 48 14.3. 6-Zone Mode
- 49 14.4. ATZ (Advanced Technology Zone) Mode
- 50 14.5. Zone Type Definitions
- 51 14.6. Zone Attributes
- 54 14.7. Bypassing and Activating Zones
- 54 14.8. Zone Names
- 55 14.9. Disabling and Enabling Zones
- 56 15. STAY MODE
- 57 16. TAMPERS
- 57 16.1. Tamper Names
- 58 17. ALARM INDICATIONS AND NOTIFICATIONS
- 59 17.1. Enabling and Disabling Alarm Notifications
- 62 18. PROGRAMMABLE (PGM) OUTPUTS
- 62 18.1. PGM Output Numbering
- 62 18.2. PGM Output Expansion
- 63 18.3. PGM Output Names
- 63 18.4. Turning PGM Outputs ON and OFF
- 65 18.5. PGM Output Control by Event and Scheduler
- 66 18.6. Wireless PGM Output Type Definitions
- 67 19. WIRELESS DEVICES
- 67 19.1. Binding, Removing and Replacing Wireless Devicess
- 69 19.2. Wireless Device Information and Signal Status Monitoring
- 70 19.3. Disabling and Enabling Siren if Wireless Signal is Lost
- 71 20. SIREN/BELL
- 72 20.1. Bell Squawk
- 72 20.2. Indication by EWS2 Indicators
- 73 20.3. EWF1 Interconnection
- 74 21. BACKUP BATTERY, MAINS POWER SUPPLY STATUS MONITORING AND MEMORY
- 77 22. GSM CONNECTION STATUS MONITORING
- 78 23. PARTITIONS
- 78 23.1. Zone Partition
- 78 23.2. User Phone Number Partition
- 79 23.3. Keypad Partition and Keypad Partition Switch
- 80 23.4. User Password Partition
- 80 23.5. iButton Key Partition
- 80 23.6. EWK1/EWK2 Wireless Keyfob Partition
- 81 24. TEMPERATURE SENSORS
- 81 24.1. Adding, Removing and Replacing Temperature Sensors
- 81 24.2. Setting Up MIN and MAX Temperature Boundaries. Temperature Info SMS
- 83 25. REMOTE LISTENING AND 2-WAY VOICE COMMUNICATION
- 84 26. SYSTEM INFORMATION. INFO SMS
- 84 26.1. Periodic Info SMS
- 86 27. SYSTEM NOTIFICATIONS
- 89 27.1. SMSC (Short Message Service Center) Phone Number
- 90 28. EVENT LOG
- 91 29. INDICATION OF SYSTEM FAULTS
- 93 30. MONITORING STATION
- 94 30.1. Data Messages – Events
- 98 30.2. Communication
- 108 31. ELDES WIRED DEVICES
- 108 31.1. RS485 Interface
- 121 31.2. 1-Wire Interface
- 121 31.3. Modules Interface
- 126 32. ELDES WIRELESS DEVICES
- 126 32.1. EWT1 - Wireless Transmitter-Receiver
- 127 32.2. EW1 - Wireless Zone & PGM Output Expansion Module
- 129 32.3. EWP1 – Wireless Motion Detector
- 131 32.4. EWD1 – Wireless Magnetic Door Contact
- 133 32.5. EWK1 - Wireless Keyfob
- 135 32.6. EWS1 – Wireless Indoor Siren
- 137 32.7. EWS2 – Wireless Outdoor Siren
- 140 32.8. EW1B - Battery-Powered Wireless Zone & PGM Output Expansion Module
- 143 32.9. EWF1 - Wireless Smoke Detector
- 148 32.10. EWK2 - Wireless Keyfob
- 151 32.11. EWD2 - Wireless Door Contact/Shock Sensor/Water Sensor
- 155 32.12. EWS3 - Wireless Indoor Siren
- 159 33. REMOTE SYSTEM RESTART
- 160 34. TECHNICAL SUPPORT
- 160 34.1. Troubleshooting
- 160 34.2. Restoring Default Parameters
- 160 34.3. Updating the Firmware via USB Cable Locally
- 161 34.4. Updating Firmware via GPRS Connection Remotely
- 162 34.5. Frequently Asked Questions
- 164 35. RELATED PRODUCTS