advertisement
![2. Technical Specifications. Eldes EKB3 | Manualzz 2. Technical Specifications. Eldes EKB3 | Manualzz](http://s1.manualzz.com/store/data/001731187_1-63f6db8abae8ee33f0d3ba1fa4d45eb5-360x466.png)
2. TECHNICAL SPECIFICATIONS
2.1. Electrical & Mechanical Characteristics
Electrical & Mechanical Characteristics
Main power supply
Current in standby without external sensors and keypad
Recommended backup battery voltage, capacity
Recommended backup battery type
Maximum battery charge current
Gsm modem frequency
Cable type for GSM/GPRS antenna connection
Number of zones on-board
Nominal zone resistance
Number of PGM outputs on-board
On-board PGM output circuit
16-24V 50 Hz ~1.5A max / 18-24V
Up to 80mA
12V; 1,3-7 Ah
Lead-Acid
900mA
850/900/1800/1900MHz
Shielded
6 (ATZ mode: 12)
5,6kΩ (ATZ Mode: 5,6kΩ and 3,3kΩ)
4
1 R OUT
1,5A max
Open Collector Output.
Output is pulled to COM when turned ON.
Maximum commuting on-board PGM output values
BELL: Siren output when activated
BELL: Maximum cable length for siren connection
BELL: Cable type for siren connection
4 x Voltage – 30V; current – 500mA.
Connected to COM
Up to 100 meters
Unshielded
AUX: Auxiliary equipment power supply voltage 13,8V DC
BELL+AUX: Maximum accumulative current of auxiliary equipment & siren 1 A
AUX: Maximum cable length for auxiliary equipment connection
AUX: Cable type for auxiliary equipment connection
Up to 100 meters
Unshielded
BUZ: Maximum current of mini buzzer
BUZ: Power supply voltage of buzzer
BUZ: Cable type for mini buzzer connection
Supported temperature sensor model
Maximum supported number of temperature sensors
DATA: Maximum cable length for 1-Wire communication
DATA: Cable type for 1-Wire communication
Supported ibutton key model
150mA
5V DC
Unshielded
Maxim®/Dallas® DS18S20, DS18B20
1
Up to 30 meters
Unshielded
Maxim®/Dallas® DS1990A
Maximum supported number of iButton keys
Maximum supported number of keypads
Y/G: Maximum cable length for RS485 communication
Y/G: Cable type for RS485 communication
MIC: Maximum cable length for microphone connection
MIC: Cable type for microphone connection
Wireless transmitter-receiver frequency
Wireless communication range
Maximum supported number of wireless devices
Event log size
Maximum supported number of zones
Maximum supported number of pgm outputs
Cable type for zone and pgm output connection
Communications
Supported protocols
Dimensions
Operating temperature range
Humidity
5
4 x EKB2 / EKB3
Up to 100 meters
Unshielded
Up to 2 meters
Unshielded
868 Mhz
Up to 30m in premises; up to 150m in open areas
16
500 events
44
44
Unshielded
SMS, Voice calls, GPRS network, RS485, CSD
Ademco Contact ID, EGR100, Kronos, Cortex SMS
140x100x18mm
-20...+55 °C
0-90% RH @ 0... +40 °C (non-condensing)
12 EN MANUAL ELDES ESIM264 V3.1
advertisement
Related manuals
advertisement
Table of contents
- 6 1. GENERAL INFORMATION
- 6 1.1. Functionality
- 6 1.2. Compatible Device Overview
- 6 1.3. Default Parameters & Ways of Parameter Configuration
- 12 2. Technical Specifications
- 12 2.1. Electrical & Mechanical Characteristics
- 13 2.2. Main Unit, LED & Connector Functionality
- 14 2.3. Wiring Diagrams
- 20 3. INSTALLATION
- 24 4. GENERAL OPERATIONAL DESCRIPTION
- 25 5. CONFIGURATION METHODS
- 28 6. PASSWORDS
- 29 7. SYSTEM LANGUAGE
- 30 8. USER PHONE NUMBERS
- 31 8.1. System Control from any Phone Number
- 33 9. DATE AND TIME
- 34 10. USER PASSWORDS
- 36 11. iBUTTON KEYS
- 36 11.1. Adding and Removing iButton Keys
- 38 12. ARMING AND DISARMING
- 38 12.1. Free of Charge Phone Call
- 39 12.2. SMS Text Message
- 40 12.3. EKB2 Keypad and User Password
- 41 12.4. EKB3 Keypad and User Password
- 42 12.5. iButton Key
- 42 12.6. EWK1/EWK2 Wireless Keyfob
- 43 12.7. Arm-Disarm by Zone
- 44 12.8. Disabling and Enabling Arm/Disarm Notifications
- 46 13. EXIT AND ENTRY DELAY
- 48 14. ZONES
- 48 14.1. Zone Numbering
- 48 14.2. Zone Expansion
- 48 14.3. 6-Zone Mode
- 49 14.4. ATZ (Advanced Technology Zone) Mode
- 50 14.5. Zone Type Definitions
- 51 14.6. Zone Attributes
- 54 14.7. Bypassing and Activating Zones
- 54 14.8. Zone Names
- 55 14.9. Disabling and Enabling Zones
- 56 15. STAY MODE
- 57 16. TAMPERS
- 57 16.1. Tamper Names
- 58 17. ALARM INDICATIONS AND NOTIFICATIONS
- 59 17.1. Enabling and Disabling Alarm Notifications
- 62 18. PROGRAMMABLE (PGM) OUTPUTS
- 62 18.1. PGM Output Numbering
- 62 18.2. PGM Output Expansion
- 63 18.3. PGM Output Names
- 63 18.4. Turning PGM Outputs ON and OFF
- 65 18.5. PGM Output Control by Event and Scheduler
- 66 18.6. Wireless PGM Output Type Definitions
- 67 19. WIRELESS DEVICES
- 67 19.1. Binding, Removing and Replacing Wireless Devicess
- 69 19.2. Wireless Device Information and Signal Status Monitoring
- 70 19.3. Disabling and Enabling Siren if Wireless Signal is Lost
- 71 20. SIREN/BELL
- 72 20.1. Bell Squawk
- 72 20.2. Indication by EWS2 Indicators
- 73 20.3. EWF1 Interconnection
- 74 21. BACKUP BATTERY, MAINS POWER SUPPLY STATUS MONITORING AND MEMORY
- 77 22. GSM CONNECTION STATUS MONITORING
- 78 23. PARTITIONS
- 78 23.1. Zone Partition
- 78 23.2. User Phone Number Partition
- 79 23.3. Keypad Partition and Keypad Partition Switch
- 80 23.4. User Password Partition
- 80 23.5. iButton Key Partition
- 80 23.6. EWK1/EWK2 Wireless Keyfob Partition
- 81 24. TEMPERATURE SENSORS
- 81 24.1. Adding, Removing and Replacing Temperature Sensors
- 81 24.2. Setting Up MIN and MAX Temperature Boundaries. Temperature Info SMS
- 83 25. REMOTE LISTENING AND 2-WAY VOICE COMMUNICATION
- 84 26. SYSTEM INFORMATION. INFO SMS
- 84 26.1. Periodic Info SMS
- 86 27. SYSTEM NOTIFICATIONS
- 89 27.1. SMSC (Short Message Service Center) Phone Number
- 90 28. EVENT LOG
- 91 29. INDICATION OF SYSTEM FAULTS
- 93 30. MONITORING STATION
- 94 30.1. Data Messages – Events
- 98 30.2. Communication
- 108 31. ELDES WIRED DEVICES
- 108 31.1. RS485 Interface
- 121 31.2. 1-Wire Interface
- 121 31.3. Modules Interface
- 126 32. ELDES WIRELESS DEVICES
- 126 32.1. EWT1 - Wireless Transmitter-Receiver
- 127 32.2. EW1 - Wireless Zone & PGM Output Expansion Module
- 129 32.3. EWP1 – Wireless Motion Detector
- 131 32.4. EWD1 – Wireless Magnetic Door Contact
- 133 32.5. EWK1 - Wireless Keyfob
- 135 32.6. EWS1 – Wireless Indoor Siren
- 137 32.7. EWS2 – Wireless Outdoor Siren
- 140 32.8. EW1B - Battery-Powered Wireless Zone & PGM Output Expansion Module
- 143 32.9. EWF1 - Wireless Smoke Detector
- 148 32.10. EWK2 - Wireless Keyfob
- 151 32.11. EWD2 - Wireless Door Contact/Shock Sensor/Water Sensor
- 155 32.12. EWS3 - Wireless Indoor Siren
- 159 33. REMOTE SYSTEM RESTART
- 160 34. TECHNICAL SUPPORT
- 160 34.1. Troubleshooting
- 160 34.2. Restoring Default Parameters
- 160 34.3. Updating the Firmware via USB Cable Locally
- 161 34.4. Updating Firmware via GPRS Connection Remotely
- 162 34.5. Frequently Asked Questions
- 164 35. RELATED PRODUCTS