23. PARTITIONS. Eldes EKB3

Add to My manuals
168 Pages

advertisement

23. PARTITIONS. Eldes EKB3 | Manualzz

23. PARTITIONS

ESIM264 system comes equipped with a partitioning feature that can divide the alarm system into two independently controlled areas identified as Partition 0 through 1, which are all supervised by one alarm system unit. Partitioning can be used in installations where shared alarm system is more practical, such as a house and a garage or within a single multi-storey building. When partitioned, each system element, like zone, user phone number, keypad, user password, iButton key and wireless keyfob can be assigned to one of the partitions. The user will then be able to arm/disarm the system partition that the zones and arm/disarm method are assigned to.

23.1. Zone Partition

Zone partition determines which system partition (-s) the zone will operate in.

Set zone partition EKB2

EKB3

Menu path:

On-board zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → ONBOARD

ZONES → OK → ZONE 1... 12 → OK → PARTITION → OK → PARTITION0... 1 → OK

Wireless zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → WIRELESS

ZONES → OK → WLESS ZONE 1... 16 → OK → PARTITION → OK → PARTITION0... 1 → OK

Keypad zone: OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → KEYPAD

ZONES → OK → KEYPAD 1... 4 ZONE → OK → PARTITION → OK → PARTITION0... 1 → OK

EPGM1 zone : OK → CONFIGURATION → OK → aaaa → OK → ZONES → OK → EPGM1 ZONES →

OK → EPGM1 ZONE 1... 16 → OK → PARTITION → OK → PARTITION0... 1 → OK

Value: aaaa – 4-digit administrator password.

Enter parameter 57, zone number & partition value:

57 nn p #

Value: nn – zone number, range – [01... 44]; p – partition number, range – [0... 1].

Example: 57031#

Config

Tool

This operation may be carried out from the PC using the ELDES Configuration Tool software.

23.2. User Phone Number Partition

User phone number partition determines which system partition (-s) can be armed/disarmed from a certain user phone number by dialing system’s phone number.

Set user phone number partition

EKB2

EKB3

Menu path:

OK → CONFIGURATION → OK → aaaa → OK → PRIMARY SETTINGS → OK → CALL/SMS

SETTINGS → OK → USERS → OK → USER 1... 5 → OK → PARTITION → OK→ PARTITION0... 1

→ OK

Value: aaaa – 4-digit administrator password.

Enter parameter 59, user phone number slot & partition number:

59 us p #

Value: nn – zone number, range – [01... 44]; p – partition number, range – [0... 1].

Example: 59030#

Config

Tool

This operation may be carried out from the PC using the ELDES Configuration Tool software.

78 EN MANUAL ELDES ESIM264 V3.1