8 EVM Series

Applications

EVM Series

Applications

A real-time, direct reading dust monitor is used in many different applications such as walk-through surveys in manufacturing, wood making plants and/or bakery shops, background sampling, site dust measurements, assessment of the effectiveness of dust control systems, and measurement of indoor air quality (IAQ). It is also used to analyze work-place exposure and help identify dust control techniques such as training or implementing engineering controls.

Time history: manufacturing

 Industrial setting - Used to monitor and ensure health and safety in settings where toxic fumes are released

(such as testing levels at a paper mill or a foundry). This information can be used to identify the source and particle concentrations.

 Sick Building syndrome – Used to evaluate air toxins and ensure building standards maintain a comfortable work setting.

 Work site assessments.

 Military applications.

 Outdoor monitoring applications include construction sites/dust outside of mines.

 Regulatory compliance (i.e., OSHA, MSHA, IEC,

ACGIH).

 As a mapping device - Layout a grid of high contaminant areas, and quickly collect sample data at multiple locations to help identify paths and sources, by relative readings.

 As a survey monitor

 Specific area in a plant/facility – used to maintain a quality work environment and conduct area monitoring samples throughout an entire facility.

Specific areas in a plant/facility - used to identify key areas that may be toxic or unsafe and implement acceptable practices such as changes in the ventilation.

EVM Series User Manual

9 EVM Series

Models Explained

Models Explained

The EVM Series simultaneously measures and data logs specific sensors/parameters that were ordered with your instrument. The models, sensors, and accessories are explained in detail below. Refer to the part’s listing for further details (such as calibration accessories).

Optional Sensor Accessories

 Air Probe-10

Models and Sensors

EVM-7 includes:

 Particulates

 Carbon monoxide (CO) or (1) selectable toxic gas

 Selectable toxic gas sensors include:

1. Carbon Monoxide (CO) 2. Chlorine (CL2)

3. Ethylene Oxide (ETO) 4. Hydrogen Cyanide (HCN)

5. Hydrogen Sulfide (H

2

S) 6. Nitric Oxide (NO)

7. Nitrogen Dioxide (NO

2

) 8. Oxygen (O

2

)

9. Sulphur Dioxide (SO

2

)

 Volatile Organic Compounds with PID ppm or PID ppb sensor

 ppm – parts per million (0 – 2,000 ppm)

 ppb – parts per billion (0 – 50,0000 ppb)

 Relative Humidity

 Temperature

 Carbon Dioxide (CO2)

EVM-4 includes:

 Carbon monoxide (CO) or selectable toxic gas

 Relative Humidity

 Temperature

 Carbon Dioxide (CO

2

)

EVM-3 includes:

 Particulates

 Relative Humidity

 Temperature

 Air Probe-10

 Toxic sensor/CO sensor

 CO

2

sensor

 PID sensor

 Particulates

 Air Probe-10

 Toxic sensor/CO sensor

 CO

2

sensor

 PID sensor

EVM Series User Manual