X64-CL iPro Series User's Manual

Add to My manuals
137 Pages

advertisement

X64-CL iPro Series User's Manual | Manualzz

Line Trigger Source Selection for Linescan

Applications

Linescan imaging applications require some form of external event trigger to synchronize linescan camera exposures to the moving object. This synchronization signal is either an external trigger source

(one exposure per trigger event) or a shaft encoder source composed of a single or dual phase

(quadrature) signal. The X64-CL iPro shaft encoder inputs provide additional functionality with pulse drop or pulse multiply support.

The following table describes the line trigger source types supported by either the X64-CL iPro or

X64-CL iPro\Lite boards. Refer to the Sapera Acquisition Parameters Reference Manual (OC-SAPM-

APR00) for descriptions of the Sapera parameters.

CORACQ_PRM_EXT_LINE_TRIGGER_SOURCE – Parameter

Values Specific to the X64-CL iPro series

PRM Value Active Shaft Encoder Input

4

5

2

3

0 Default

1 Use phase A

Use phase B

Use phase A & B

6

From Board Sync

Phase A & B, shaft encoder after pulse drop/multiply output to

Board Sync

Phase A & B, camera line trigger output to Board Sync

X64-CL iPro Series User's Manual

X64-CL iPro Reference 59

CORACQ_PRM_EXT_LINE_TRIGGER_SOURCE full description relative to trigger type and X64-CL iPro configuration used:

PRM

Value

X64-CL iPro configuration & camera input used

External Line Trigger Signal used

External Shaft Encoder Signal used

1

0

Dual - Camera #1

Dual - Camera #2

Medium - Camera #1

Dual - Camera #1

Dual - Camera #2

Medium - Camera #1

2

Dual - Camera #1

Dual - Camera #2

Medium - Camera #1

3, 5, 6

Dual - Camera #1

Dual - Camera #2

4

Medium - Camera #1

Dual Camera #1

Dual Camera #2

Medium Camera #1

if

CORACQ_PRM_EXT_LINE_

TRIGGER_ENABLE = true

Shaft Encoder Phase A

Shaft Encoder Phase B

Shaft Encoder Phase A

Shaft Encoder Phase A

Shaft Encoder Phase A

Shaft Encoder Phase A

Shaft Encoder Phase B

Shaft Encoder Phase B

Shaft Encoder Phase B n/a n/a n/a

From Board Sync

From Board Sync

From Board Sync

See "

J4: External Signals Connector

" on page 95 for shaft encoder input connector details.

CVI/CCF File Parameters Used

• External Line Trigger Source = prm value

• External Line Trigger Enable = true/false

• Shaft Encoder Enable = true/false

if

CORACQ_PRM_SHAFT_

ENCODER_ENABLE =true

Shaft Encoder Phase A

Shaft Encoder Phase B

Shaft Encoder Phase A & B

Shaft Encoder Phase A

Shaft Encoder Phase A

Shaft Encoder Phase A

Shaft Encoder Phase B

Shaft Encoder Phase B

Shaft Encoder Phase B

Shaft Encoder Phase A & B

Shaft Encoder Phase A & B

Shaft Encoder Phase A & B

From Board Sync

From Board Sync

From Board Sync