X64-CL iPro Series User's Manual

Add to My manuals
137 Pages

advertisement

X64-CL iPro Series User's Manual | Manualzz

Appendix: X-I/O Module

Option

X-I/O Module Overview

• The X-I/O module requires X64-CL iPro board driver version 1.10 (or later) and Sapera LT version 5.30 (or later).

• Occupies an adjacent slot to the X64-CL iPro. Slot can be either PCI-32 or PCI-64—no PCI signals or power are used.

• Connects to the X64-CL iPro via a 26 pin flat ribbon cable. J21 on X-I/O to J4 on X64-CL iPro.

Note that the external signals connector bracket is removed.

• All X64-CL iPro external signals, such as trigger, shaft encoder, strobe, are available on the

X-I/O DB37. See

" DB37 Pinout Description " on page 112

.

• X-I/O provides 8 outputs software selectable as NPN (current sink) or PNP (source driver) type drivers. See

" Outputs in NPN Mode: Electrical Details " on page 113

and

" Outputs in PNP

Mode: Electrical Details

" on page 114 .

• X-I/O provides 2 opto-coupled inputs. See

"

Opto-coupled Input: Electrical Details

" on page 115 .

• X-I/O provides 6 TTL level inputs with software selectable transition point. See

" TTL Input

Electrical Details

" on page 115 .

• X-I/O provides both +5 volt and +12 volt power output pins on the DB37, where power comes directly from the host system power supply.

• Onboard flash memory to store user defined power up I/O states.

X64-CL iPro Series User's Manual

Appendix: X-I/O Module Option 109

advertisement

Related manuals

Download PDF

advertisement

Table of contents