![](http://s1.manualzz.com/store/data/014871686_1-1841fd096382c1a4c1b47c8ed8c9056f-128x128.png)
advertisement
![PAR 1 RGBW User Manual Professional Entertainment Technology | Manualzz PAR 1 RGBW User Manual Professional Entertainment Technology | Manualzz](http://s1.manualzz.com/store/data/014871686_1-1841fd096382c1a4c1b47c8ed8c9056f-360x466.png)
AC power
Warning! Read ‘Safety information’ on page 5 before connecting the fixture to AC mains power.
Warning! The mains power input cable supplied with the fixture is rated 6 A and can supply only one fixture with mains power. Do not connect any device to the fixture’s
MAINS OUT power throughput socket when using this input cable. If you want to connect other fixtures to the MAINS
OUT socket, see ‘Linking fixtures to power in a chain’ on page 14.
For protection from electric shock, the fixture must be grounded
(earthed). The power distribution circuit must be equipped with a fuse or circuit breaker and ground-fault (earth-fault) protection.
Socket outlets or external power switches used to supply the fixture with power must be located near the fixture and easily accessible so that the fixture can easily be disconnected from power.
Do not insert or remove live Neutrik PowerCon connectors to apply or cut power, as this may cause arcing at the terminals that will damage the connectors.
Do not use an external dimming system to supply power to the fixture, as this may cause damage to the fixture that is not covered by the product warranty.
The fixture can be hard-wired to a building electrical installation if you want to install it permanently, or a power plug (not supplied) that is suitable for the local power outlets can be installed on the power cable.
If you install a power plug on the power cable, install a grounding type (earthed) plug with integral cable grip that is rated minimum 250 V, 6 A. Follow the plug manufacturer’s instructions and connect the wires in the power cable as shown in this table:
Live or L Neutral or N
Earth, Ground or
US system
EU system
Black White Green
Brown Blue Yellow/green
The fixture has an auto-ranging power supply that accepts AC mains power at
100V~240V, 50/60Hz. Do not apply AC mains power at any other voltage or frequency to the fixture.
RUSH PAR 1 RGBW User Manual
13
advertisement
Related manuals
advertisement
Table of contents
- 5 Safety information
- 10 Introduction
- 10 Before using the product
- 11 Physical installation
- 11 Fastening the fixture to a flat surface
- 11 Mounting the fixture on a truss
- 12 Securing with a safety cable
- 13 AC power
- 14 Linking fixtures to power in a chain
- 15 Fixture overview
- 17 Control data link
- 17 Tips for reliable data transmission
- 18 Connecting the DMX data link
- 18 Fixture setup
- 18 Using the control menus
- 18 DMX addressing
- 19 DMX channel modes
- 19 Show mode
- 20 Dimmer modes
- 21 Sound activation (music trig)
- 21 Microphone sensitivity
- 21 DMX state
- 22 LED display on/off
- 22 LED display inversion
- 22 White balance adjustment
- 23 Manual mode
- 23 Auto test
- 24 Temperature readout
- 24 Fixture operating hours readout
- 24 Firmware version
- 25 Effects
- 25 Color control
- 25 Electronic dimming
- 25 Shutter/Strobe
- 26 Maintenance
- 26 Cleaning
- 27 Replacing the primary fuse
- 27 Service and repairs
- 28 DMX protocols
- 28 4-channel mode
- 28 5-channel mode
- 28 7-channel mode
- 30 Control menus
- 33 Troubleshooting
- 35 Specifications