Explicit exchange management and reports. Schneider Electric PL7 Micro/Junior/Pro - Communication applications, volume 2
Pubblicità
Pubblicità
FIPIO language objects
Explicit exchange management and reports
Introduction
Word objects
This page describes all the language objects that manage explicit exchanges. (See
: PL7 Micro/Junior/Pro ; Communication applications ; Volume 1)
The table below shows the different word objects for the management of explicit exchanges.
Object (1)
%MW\p.2.c\
0.MOD.0
%MW\p.2.c\
0.MOD.0
Function
Module exchanges in progress
%MW\p.2.c\
0.i.0
Channel exchanges in progress
%MW\p.2.c\
0.i.1
Module report
Channel report
Meaning l l l x0 = 1: reading status in progress x1 = 1: sending of command parameters to the communication module x2 = 1: sending of adjustment parameters to the communication module l l x1 = 0: command parameters received and accepted by the module x2 = 0: adjustment parameters received and accepted by the module l l l l l l l l l x0 = 1: reading status in progress x1 = 1: sending of command parameters in progress x2 = 1: sending of adjustment parameters in progress x3 to x14: reserved (= 0) x15 = 1: sending of configuration parameters in progress l x0 = 0: status reading OK x1 = 0: command parameters received and accepted by the device x2 = 0: adjustment parameters received and accepted by the device x3 to x14: reserved (= 0) x15 = 0: configuration parameters received and accepted by the device
Key
(1) p.2.c\m.i.r Address l l l l p: corresponds to the processor’s slot c: corresponds to the connection point number m: corresponds to the module position number i: corresponds to the channel number