Viewing a Monitoring Window
When monitoring is carried out by group, the display time for each window is about 2 seconds. A four-channel data logger RTR-574displays Illuminance and UV Intensity in one window, and Temperature and Humidity in another. A three-channel data logger RTR-576 displays CO2 Concentration in one window, and Temperature and
Humidity in another.
Window for RTR-501 / 502 / 503 / 505 / 507S
EX: RTR-503 (Temperature and Humidity)
EX: RTR-505-V (Voltage) EX: RTR-505-P (Pulse)
Windows for RTR-574 / 576
EX: RTR-574 (Illuminance and UV Intensity) EX: RTR-574 (Temperature and Humidity)
Communication Functions 45
Remote Unit on Display
The horizontal axis shows the total number of Remote Units that are currently being monitored. This does not appear when monitoring only one Remote Unit. When the total number of Remote Units is 10, for example, the axis shows the 1st Remote
Unit in the left end and the 10th Unit in the right end. A black spot on the horizontal axis shows the currently displayed Remote Unit. If the spot appears in the middle of the axis, it means the 5th Remote Unit is currently displayed.
Recording Status
[REC]: Recording in Progress / [STP]: Recording Stopped / [PRG]: Programmed and Waiting
Recording Mode ( Endless / Onetime)
Recording Interval (S: seconds / M: minutes)
Battery Level
The battery level for the Remote Unit will be shown in 6 stages. When the battery level is below stage "2", wireless communication errors may occur more frequently such as failure to download recorded data.
5 (Full) 4 3 2 1 0
The Amount of Recorded Readings in the Remote Unit
The estimated number of recorded readings stored in the Remote Unit is shown in a scale here. When the Remote Unit reaches its storage capacity, the scale becomes a full black bar.
Current Readings
For Illuminance and UV Intensity data from RTR-574, cumulative measurements can also be viewed.
Upper and Lower Limit Settings
These show the current Upper and Lower Limit Settings in the Remote Unit. The display position may differ depending on the Remote Unit being used. Nothing appears if Upper and Lower Limits have not been set with the Remote Unit.
46 Communication Functions
Unit of Measurement
Temperature: °C , °F / Humidity: %RH / Illuminance: lx, klx
Cumulative Illuminance lxh, klxh, Mlxh , UV Intensity : mW/cm
Cumulative Amount of UV Light (*1) : mW/cm 2 h, W/cm 2 h
2
CO2 Concentration : ppm
Voltage : V
4-20mA : mA
Pulse (*2) : Pulse (Rising), Pulse (Falling)
* 1: For the Cumulative Amount of UV Light, “cm 2 monitoring window.( )
” is abbreviated to “s” in the
* 2: Pulse count is shown as [P / Recording Interval and rising or falling symbol], indicating the pulse count during a set recording interval. ( : Number of falling pulses at 10 second interval)
Warning Judgement ( :Warning)
This appears if and when a measurement has been judged to qualify as a warning.
Nothing appears if Upper and Lower Limits have not been set with the Remote Unit.
Remote Unit Name
This shows the Remote Unit Name entered when Remote Unit Registration was carried out.
Group Name
This shows the Group Name entered when Remote Unit Registration was carried out.
Antenna (Signal Strength)
The number of bars shows the signal strength for communication between the Base
Unit and the Remote Unit. Having more bars means better communication status.
Repeater Icon
This appears when communication is carried out via Repeater(s) as registered. This does not appear when communication is carried out without Repeater(s).
Total Pulse Count
When using an RTR-505-P (Pulse) this shows the cumulative number of pulses.
Communication Functions 47
advertisement
Related manuals
advertisement
Table of contents
- 1 Introductory Manual
- 2 Important Notices and Disclaimers
- 3 Software User’s Agreement
- 5 Table of Contents
- 6 Safety Precautions and Instructions
- 6 Explanation of Symbols
- 12 What is "RTR-500DC"?
- 12 Outline
- 12 Features of Wireless Communication Function
- 13 Features of the RTR-500DC
- 14 Before Using this Product
- 14 "Repeaters"?
- 16 Basic Procedures
- 18 Package Contents
- 18 Connect the Antenna
- 19 Appearance Diagram and Part Names
- 20 Install the Battery
- 20 Other Power Sources Available for Use
- 20 Battery Replacement
- 20 Sleep Mode
- 21 Power and Auto Power Off Function
- 21 Turning ON the Power
- 21 Turning OFF the Power
- 21 Auto Power Off Function
- 22 Operations via Buttons and Operation Dial
- 22 Using the Operation Dial
- 22 Button Functions
- 23 About the Icons and Abbreviations
- 24 Installing the Software
- 24 Before Installing the Software
- 27 Installing the USB Device Driver
- 30 1. Make Settings for Base Units
- 30 2. Register Data Loggers as Remote Units
- 30 3. Register Repeaters (when necessary)
- 31 Route Settings
- 32 Launcher Window and Applications
- 32 How to Open
- 33 Communication
- 34 and PC
- 34 Communication
- 35 and Remote Unit
- 35 Wireless Communication
- 35 RTR-500DC Units
- 36 500DC and Remote Units
- 36 Optical and Cable Communication
- 36 Cable Communication: RTR
- 38 Downloading Data by Group
- 38 Gather Data]
- 40 Window
- 41 Gather Data]
- 43 Monitoring
- 43 Monitor Mode]
- 44 Communication Conditions for Monitoring
- 45 Viewing a Monitoring Window
- 48 Warning Monitoring
- 48 Target Remote Units for Warning Monitoring
- 48 Warning Conditions
- 48 Warning Buzzer
- 49 Starting / Stopping Remote Unit Recording
- 50 Settings]
- 51 "Visitor Entry
- 51 Visitor Entry]
- 51 Registration Error Messages
- 52 "Visitor Entry
- 53 Communication Errors
- 53 When the memory capacity is full: [Memory Full]
- 54 When the Signal Strength is weak
- 54 Application related Communication Errors
- 56 Viewing Data Stored in RTR-500DC
-
56
Viewing a Data List:
- button / [Data List]
- 56 Data Lists for RTR
- 59 Viewing the Graph
-
59
Graph Display:
- button / [Data List]
- 59 How to Read the Graph
- 61 Data Range Check and Judgement
- 62 Viewing RTR-574 / 576 Data in a Graph
- 62 Data Downloaded via Wireless Communication
- 62 Data Downloaded via Cable Communication
- 63 Operating the Graph
- 63 Changing the Channel on Display
- 63 Enlarged View
- 63 Checking the Highest / Lowest Readings
- 64 Deleting Selected Data
-
64
Deleting Selected Data : [Data List] /
- button
- 66 Operational Settings for RTR-500DC
- 66 Changing Unit of Temperature
- 67 Checking Memory
- 67 Deleting All Data
- 68 Operations
- 69 Figuring Out Your Time Zone
- 69 Savings Time
- 70 Setting the Buzzer OFF
- 70 Checking Battery Status of the RTR-500DC
- 71 Monitoring Radio Waves
- 72 Menu List
- 72 Gather Data]
- 72 Monitor Mode]
- 73 Record Settings]
- 74 Visitor Entry]
- 74 Gather Data]
- 74 Record Settings]
- 75 [Data List]
- 75 [Set Functions]
- 76 Q&A about RTR-500DC
- 77 Q&A about Settings
- 79 Q&A about Operations after Settings
- 82 Specifications
- 83 Software (RTR-500DC for Windows)
- 84 Options