advertisement
![Specifications. T&D RTR-500DC | Manualzz Specifications. T&D RTR-500DC | Manualzz](http://s1.manualzz.com/store/data/068261287_1-9c5fdaf11a717877008afcf48a791582-360x466.png)
Specifications
Data Collector RTR-500DC Unit
Compatible Devices Remote Units: RTR-501 / 502 / 503 / 507S / 574 / 576 / 505-TC / 505-
Pt /
505-V / 505-mA / 505-P
(Including L Type and S Type)
Maximum Number of
Registrations
Repeater: RTR-500
Remote Units: 32 units (*1) x 7 groups
Repeaters: 15 units x 7 groups
Storage Capacity
Communication
Interfaces
When downloading from units filled to logging capacity:
- 15 units of RTR-501 / 502 / 503 / 505 / 507S
- 7 units of RTR-574
- 10 units of RTR-576
When downloading from units of any type containing small amounts of data, it can store and manage up to 250 download sessions.
<Between Base Unit(s) - (Repeaters) - Remote Unit(s)>
- Short Range Wireless Communication
ETSI EN 300 220
Frequency Range: 869.7 to 870MHz, RF Power: 5 mW
- Optical Communication
With compatible Remote Units except RTR-574 and RTR-576
- Serial Communication RS-232C (*2)
With RTR-574 and RTR-576
Wireless
Transmission Range
Communication
Time
<Between Base Unit - PC>
- USB Communication
- Serial Communication RS-232C (*3)
Approx. 150 meters (500 ft) if direct and unobstructed
Power
Battery Life (*4)
Dimensions
Data Download Time from Remote Unit (for 16,000 readings)
- Via wireless communication: About 2 min.
The same amount of time will be necessary for each Repeater.
- Via optical communication: About 3 min.
- Via serial communication: About 22 sec.
AAA Alkaline Battery LR03 x 2, AAA Ni-MH Battery x 2,
AC Adaptor AD-06C1, USB bus power
Expected battery life with 2 AAA alkaline batteries:
- Monitoring Current Readings and Remote Unit Status: 96 hours of continuous use
(For communication without Repeaters at 60 second intervals)
- Monitoring Radio Waves: 32 hours of continuous use
- Downloading Data via Wireless Communication: 730 consecutive sessions
(When downloading RTR-501 at full logging capacity, without
Repeaters, with LCD backlight Off )
H 125 mm x W 58 mm x D 26.3 mm (excluding antenna)
Antenna Length: 109 mm
82 Making the RTR-500DC Unit Settings / Other Functions
advertisement
Related manuals
advertisement
Table of contents
- 1 Introductory Manual
- 2 Important Notices and Disclaimers
- 3 Software User’s Agreement
- 5 Table of Contents
- 6 Safety Precautions and Instructions
- 6 Explanation of Symbols
- 12 What is "RTR-500DC"?
- 12 Outline
- 12 Features of Wireless Communication Function
- 13 Features of the RTR-500DC
- 14 Before Using this Product
- 14 "Repeaters"?
- 16 Basic Procedures
- 18 Package Contents
- 18 Connect the Antenna
- 19 Appearance Diagram and Part Names
- 20 Install the Battery
- 20 Other Power Sources Available for Use
- 20 Battery Replacement
- 20 Sleep Mode
- 21 Power and Auto Power Off Function
- 21 Turning ON the Power
- 21 Turning OFF the Power
- 21 Auto Power Off Function
- 22 Operations via Buttons and Operation Dial
- 22 Using the Operation Dial
- 22 Button Functions
- 23 About the Icons and Abbreviations
- 24 Installing the Software
- 24 Before Installing the Software
- 27 Installing the USB Device Driver
- 30 1. Make Settings for Base Units
- 30 2. Register Data Loggers as Remote Units
- 30 3. Register Repeaters (when necessary)
- 31 Route Settings
- 32 Launcher Window and Applications
- 32 How to Open
- 33 Communication
- 34 and PC
- 34 Communication
- 35 and Remote Unit
- 35 Wireless Communication
- 35 RTR-500DC Units
- 36 500DC and Remote Units
- 36 Optical and Cable Communication
- 36 Cable Communication: RTR
- 38 Downloading Data by Group
- 38 Gather Data]
- 40 Window
- 41 Gather Data]
- 43 Monitoring
- 43 Monitor Mode]
- 44 Communication Conditions for Monitoring
- 45 Viewing a Monitoring Window
- 48 Warning Monitoring
- 48 Target Remote Units for Warning Monitoring
- 48 Warning Conditions
- 48 Warning Buzzer
- 49 Starting / Stopping Remote Unit Recording
- 50 Settings]
- 51 "Visitor Entry
- 51 Visitor Entry]
- 51 Registration Error Messages
- 52 "Visitor Entry
- 53 Communication Errors
- 53 When the memory capacity is full: [Memory Full]
- 54 When the Signal Strength is weak
- 54 Application related Communication Errors
- 56 Viewing Data Stored in RTR-500DC
-
56
Viewing a Data List:
- button / [Data List]
- 56 Data Lists for RTR
- 59 Viewing the Graph
-
59
Graph Display:
- button / [Data List]
- 59 How to Read the Graph
- 61 Data Range Check and Judgement
- 62 Viewing RTR-574 / 576 Data in a Graph
- 62 Data Downloaded via Wireless Communication
- 62 Data Downloaded via Cable Communication
- 63 Operating the Graph
- 63 Changing the Channel on Display
- 63 Enlarged View
- 63 Checking the Highest / Lowest Readings
- 64 Deleting Selected Data
-
64
Deleting Selected Data : [Data List] /
- button
- 66 Operational Settings for RTR-500DC
- 66 Changing Unit of Temperature
- 67 Checking Memory
- 67 Deleting All Data
- 68 Operations
- 69 Figuring Out Your Time Zone
- 69 Savings Time
- 70 Setting the Buzzer OFF
- 70 Checking Battery Status of the RTR-500DC
- 71 Monitoring Radio Waves
- 72 Menu List
- 72 Gather Data]
- 72 Monitor Mode]
- 73 Record Settings]
- 74 Visitor Entry]
- 74 Gather Data]
- 74 Record Settings]
- 75 [Data List]
- 75 [Set Functions]
- 76 Q&A about RTR-500DC
- 77 Q&A about Settings
- 79 Q&A about Operations after Settings
- 82 Specifications
- 83 Software (RTR-500DC for Windows)
- 84 Options