![Viewing the Graph. T&D RTR-500DC | Manualzz Viewing the Graph. T&D RTR-500DC | Manualzz](http://s1.manualzz.com/store/data/068261287_1-9c5fdaf11a717877008afcf48a791582-360x466.png)
Viewing the Graph
Graph Display: <List> button / [Data List]
1. Press the <List> button on the RTR-500DC or open [Data List] in the Main Menu to view the Data List.
2. Select data from the list and click [Graph Display] to view the data in graph form.
- Press the Operation Dial to cancel the Graph Display.
How to Read the Graph
A graph is displayed for each channel of data.
Cursor Line (blinking)
By moving the Operation Dial, you can scroll the cursor line left and right.
Channels for Display
If there are multiple channels of recorded data, you can change the channel on display by holding in the Operation Dial (for about one second).
Recording Interval and Mode
The "Recording Interval" and "Recording Mode" for the displayed data are shown here.
Example: = 2-second interval, One Time Mode
= 30-minute interval, Endless Mode
Date and Time of Cursor Position
The date and time of the current cursor position are shown here.
Graph Display Range
When a portion of the graph has been zoomed-in on, this line shows the range of data currently on display from the entire range of recorded data.
Upper Limit / Lower Limit
If Upper and/or Lower Limits have been set in the Remote Units, these limits will be shown using thick dotted lines.
VIewing Functions 59
Measurement at Cursor Position
The corresponding measurement value is displayed for the date and time where the cursor is positioned.
Temperature: °C , °F
Humidity: %RH
Illuminance: lx, klx
UV Intensity : mW/cm 2
CO2 Concentration : ppm
Voltage : V
4-20mA : mA
Pulse : Pulse (Rising), Pulse (Falling)
60 Viewing Functions
advertisement
Related manuals
advertisement
Table of contents
- 1 Introductory Manual
- 2 Important Notices and Disclaimers
- 3 Software User’s Agreement
- 5 Table of Contents
- 6 Safety Precautions and Instructions
- 6 Explanation of Symbols
- 12 What is "RTR-500DC"?
- 12 Outline
- 12 Features of Wireless Communication Function
- 13 Features of the RTR-500DC
- 14 Before Using this Product
- 14 "Repeaters"?
- 16 Basic Procedures
- 18 Package Contents
- 18 Connect the Antenna
- 19 Appearance Diagram and Part Names
- 20 Install the Battery
- 20 Other Power Sources Available for Use
- 20 Battery Replacement
- 20 Sleep Mode
- 21 Power and Auto Power Off Function
- 21 Turning ON the Power
- 21 Turning OFF the Power
- 21 Auto Power Off Function
- 22 Operations via Buttons and Operation Dial
- 22 Using the Operation Dial
- 22 Button Functions
- 23 About the Icons and Abbreviations
- 24 Installing the Software
- 24 Before Installing the Software
- 27 Installing the USB Device Driver
- 30 1. Make Settings for Base Units
- 30 2. Register Data Loggers as Remote Units
- 30 3. Register Repeaters (when necessary)
- 31 Route Settings
- 32 Launcher Window and Applications
- 32 How to Open
- 33 Communication
- 34 and PC
- 34 Communication
- 35 and Remote Unit
- 35 Wireless Communication
- 35 RTR-500DC Units
- 36 500DC and Remote Units
- 36 Optical and Cable Communication
- 36 Cable Communication: RTR
- 38 Downloading Data by Group
- 38 Gather Data]
- 40 Window
- 41 Gather Data]
- 43 Monitoring
- 43 Monitor Mode]
- 44 Communication Conditions for Monitoring
- 45 Viewing a Monitoring Window
- 48 Warning Monitoring
- 48 Target Remote Units for Warning Monitoring
- 48 Warning Conditions
- 48 Warning Buzzer
- 49 Starting / Stopping Remote Unit Recording
- 50 Settings]
- 51 "Visitor Entry
- 51 Visitor Entry]
- 51 Registration Error Messages
- 52 "Visitor Entry
- 53 Communication Errors
- 53 When the memory capacity is full: [Memory Full]
- 54 When the Signal Strength is weak
- 54 Application related Communication Errors
- 56 Viewing Data Stored in RTR-500DC
-
56
Viewing a Data List:
- button / [Data List]
- 56 Data Lists for RTR
- 59 Viewing the Graph
-
59
Graph Display:
- button / [Data List]
- 59 How to Read the Graph
- 61 Data Range Check and Judgement
- 62 Viewing RTR-574 / 576 Data in a Graph
- 62 Data Downloaded via Wireless Communication
- 62 Data Downloaded via Cable Communication
- 63 Operating the Graph
- 63 Changing the Channel on Display
- 63 Enlarged View
- 63 Checking the Highest / Lowest Readings
- 64 Deleting Selected Data
-
64
Deleting Selected Data : [Data List] /
- button
- 66 Operational Settings for RTR-500DC
- 66 Changing Unit of Temperature
- 67 Checking Memory
- 67 Deleting All Data
- 68 Operations
- 69 Figuring Out Your Time Zone
- 69 Savings Time
- 70 Setting the Buzzer OFF
- 70 Checking Battery Status of the RTR-500DC
- 71 Monitoring Radio Waves
- 72 Menu List
- 72 Gather Data]
- 72 Monitor Mode]
- 73 Record Settings]
- 74 Visitor Entry]
- 74 Gather Data]
- 74 Record Settings]
- 75 [Data List]
- 75 [Set Functions]
- 76 Q&A about RTR-500DC
- 77 Q&A about Settings
- 79 Q&A about Operations after Settings
- 82 Specifications
- 83 Software (RTR-500DC for Windows)
- 84 Options