advertisement
![Viewing Data Stored in RTR-500DC. T&D RTR-500DC | Manualzz Viewing Data Stored in RTR-500DC. T&D RTR-500DC | Manualzz](http://s1.manualzz.com/store/data/068261287_1-9c5fdaf11a717877008afcf48a791582-360x466.png)
Viewing Data Stored in RTR-500DC
Here you can view and check data stored in the RTR-500DC Unit.
Viewing a Data List: <List> button / [Data List]
1. Press the <List> button on the RTR-500DC or open [Data List] in the Main Menu to view the Data List.
List No.
This shows the number assigned automatically in the order the data was downloaded.
Device Type (Remote Unit)
Remote Unit Name
This shows the Remote Unit Name entered when Remote Unit Registration was carried out.
Data Lists for RTR-574 / 57
The data list display for the RTR-574 and RTR-576 changes depending on the communication method used for the download: Wireless
Communication or Cable Communication.
Example of RTR-574 data lists
Data Downloaded via Wireless
Communication
Data Downloaded via Cable
Communication
Data Downloaded via Wireless Communication
For the RTR-574, the downloaded data is stored as two sets of data: "Illuminance and UV Intensity" [No.8] and "Temperature and Humidity" [No.9]. (Data
List [No.8] and [No.9]) For the RTR-576, the downloaded data is stored as two sets of data: "CO2 Concentration" and "Temperature and Humidity".
Data Downloaded via Cable Communication
When the data is downloaded via a communication cable, the data is stored as one set of data for all four channels (RTR-574) or all three channels (RTR-576).
(Data List [No.6])
56 Viewing Functions
Detailed Information of Data: <List> button / [Data List]
1.
Press the <List> button on the RTR-500DC or open [Data List] in the Main Menu to view the Data List.
2. Select data from the list and press the <List> button to open the detailed info window.
3. By moving the Operation Dial up and down and selecting different data, it is possible to view the detailed info of all data in numerical order in the list.
For RTR-501 / 502 / 503 / 505 / 507S / 576
Example of RTR-503 data details Example of RTR-505-Pt data details
For RTR-574
Example of Data including Illuminance and UV Intensity
Device Type (Remote Unit)
Recording Interval and Mode
This shows the Recording Interval and Mode set in the Remote Unit.
Example: = 2-second interval, One Time Mode
= 30-minute interval, Endless Mode
Number of Recorded Data
[Collect]: Data Collection Date / Time
This shows the date and time when data was downloaded into RTR-500DC.
[Start]: Recording Start Date / Time
This shows the date and time when recording was started in the Remote Unit.
VIewing Functions 57
[Latest]: Date / Time of Latest Data
This shows the date and time that of the last recording.
Cumulative Values
For Illuminance and UV Intensity data from RTR-574, cumulative measurements can also be viewed.
[NAME]: Remote Unit Name
This shows the Remote Unit Name entered when Remote Unit Registration was carried out.
[GROUP]: Group Name
When downloading data from the Remote Unit which has not been registered in the
RTR-500DC, the group name will appear as " ".
[Sensor]: Type of Connected Sensor
When using an RTR-505-TC (Thermocouple) or an RTR-505-Pt (Pt100, Pt1000), this shows the sensor type being connected to the Remote Unit.
58 Viewing Functions
advertisement
Related manuals
advertisement
Table of contents
- 1 Introductory Manual
- 2 Important Notices and Disclaimers
- 3 Software User’s Agreement
- 5 Table of Contents
- 6 Safety Precautions and Instructions
- 6 Explanation of Symbols
- 12 What is "RTR-500DC"?
- 12 Outline
- 12 Features of Wireless Communication Function
- 13 Features of the RTR-500DC
- 14 Before Using this Product
- 14 "Repeaters"?
- 16 Basic Procedures
- 18 Package Contents
- 18 Connect the Antenna
- 19 Appearance Diagram and Part Names
- 20 Install the Battery
- 20 Other Power Sources Available for Use
- 20 Battery Replacement
- 20 Sleep Mode
- 21 Power and Auto Power Off Function
- 21 Turning ON the Power
- 21 Turning OFF the Power
- 21 Auto Power Off Function
- 22 Operations via Buttons and Operation Dial
- 22 Using the Operation Dial
- 22 Button Functions
- 23 About the Icons and Abbreviations
- 24 Installing the Software
- 24 Before Installing the Software
- 27 Installing the USB Device Driver
- 30 1. Make Settings for Base Units
- 30 2. Register Data Loggers as Remote Units
- 30 3. Register Repeaters (when necessary)
- 31 Route Settings
- 32 Launcher Window and Applications
- 32 How to Open
- 33 Communication
- 34 and PC
- 34 Communication
- 35 and Remote Unit
- 35 Wireless Communication
- 35 RTR-500DC Units
- 36 500DC and Remote Units
- 36 Optical and Cable Communication
- 36 Cable Communication: RTR
- 38 Downloading Data by Group
- 38 Gather Data]
- 40 Window
- 41 Gather Data]
- 43 Monitoring
- 43 Monitor Mode]
- 44 Communication Conditions for Monitoring
- 45 Viewing a Monitoring Window
- 48 Warning Monitoring
- 48 Target Remote Units for Warning Monitoring
- 48 Warning Conditions
- 48 Warning Buzzer
- 49 Starting / Stopping Remote Unit Recording
- 50 Settings]
- 51 "Visitor Entry
- 51 Visitor Entry]
- 51 Registration Error Messages
- 52 "Visitor Entry
- 53 Communication Errors
- 53 When the memory capacity is full: [Memory Full]
- 54 When the Signal Strength is weak
- 54 Application related Communication Errors
- 56 Viewing Data Stored in RTR-500DC
-
56
Viewing a Data List:
- button / [Data List]
- 56 Data Lists for RTR
- 59 Viewing the Graph
-
59
Graph Display:
- button / [Data List]
- 59 How to Read the Graph
- 61 Data Range Check and Judgement
- 62 Viewing RTR-574 / 576 Data in a Graph
- 62 Data Downloaded via Wireless Communication
- 62 Data Downloaded via Cable Communication
- 63 Operating the Graph
- 63 Changing the Channel on Display
- 63 Enlarged View
- 63 Checking the Highest / Lowest Readings
- 64 Deleting Selected Data
-
64
Deleting Selected Data : [Data List] /
- button
- 66 Operational Settings for RTR-500DC
- 66 Changing Unit of Temperature
- 67 Checking Memory
- 67 Deleting All Data
- 68 Operations
- 69 Figuring Out Your Time Zone
- 69 Savings Time
- 70 Setting the Buzzer OFF
- 70 Checking Battery Status of the RTR-500DC
- 71 Monitoring Radio Waves
- 72 Menu List
- 72 Gather Data]
- 72 Monitor Mode]
- 73 Record Settings]
- 74 Visitor Entry]
- 74 Gather Data]
- 74 Record Settings]
- 75 [Data List]
- 75 [Set Functions]
- 76 Q&A about RTR-500DC
- 77 Q&A about Settings
- 79 Q&A about Operations after Settings
- 82 Specifications
- 83 Software (RTR-500DC for Windows)
- 84 Options