GT15
General Description
GT1585-STBA
GT1575-STBA
GT1575-VTBA
GT1565-VTBA
Thank you for purchasing the GOT1000 Series.
Prior to use, please read both this manual and detailed manual thoroughly to fully understand the product.
MODEL
MODEL
CODE
GT15-U-HW
1D7M11
IB(NA)-0800305-C(0501)MEE
SAFETY PRECAUTIONS
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly.
The precautions given in this manual are concerned with this product.
In this manual, the safety precautions are ranked as "DANGER" and "CAUTION".
DANGER
CAUTION
Indicates that incorrect handling may cause hazardous conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous conditions, resulting in medium or slight personal injury or physical damage.
Note that the caution level may lead to a serious accident according to the circumstances.
Always follow the instructions of both levels because they are important to personal safety.
Please save this manual to make it accessible when required and always forward it to the end user.
A-1
[DESIGN PRECAUTIONS]
DANGER
z Some failures of the GOT, communication unit or cable may keep the outputs on or off.
An external monitoring circuit should be provided to check for output signals which may lead to a serious accident.
Not doing so can cause an accident due to false output or malfunction.
z If a communication fault (including cable disconnection) occurs during monitoring on the GOT, communication between the GOT and PLC CPU is suspended and the GOT becomes inoperative.
For bus connection : The CPU becomes faulty and the GOT becomes inoperative.
For other than bus connection : The GOT becomes inoperative.
A system where the GOT is used should be configured to perform any significant operation to the system by using the switches of a device other than the GOT on the assumption that a GOT communication fault will occur.
Not doing so can cause an accident due to false output or malfunction.
z Do not use the GOT as the warning device that may cause a serious accident.
An independent and redundant hardware or mechanical interlock is required to configure the device that displays and outputs serious warning.
Failure to observe this instruction may result in an accident due to incorrect output or malfunction.
z Incorrect operation of the touch switch(s) may lead to a serious accident if the
GOT backlight is gone out.
When the GOT backlight goes out, the POWER LED flickers (green/orange) and the display section turns black and causes the monitor screen to appear blank, while the input of the touch switch(s) remains active.
This may confuse an operator in thinking that the GOT is in “screensaver” mode, who then tries to release the GOT from this mode by touching the display section, which may cause a touch switch to operate.
Note that the following occurs on the GOT when the backlight goes out.
z The POWER LED flickers (green/orange) and the monitor screen appears blank
A-2
[DESIGN PRECAUTIONS]
CAUTION
z Do not bundle the control and communication cables with main-circuit, power or other wiring.
Run the above cables separately from such wiring and keep them a minimum of 100mm apart.
Not doing so noise can cause a malfunction.
[MOUNTING PRECAUTIONS]
DANGER
z Be sure to shut off all phases of the external power supply used by the system before mounting or removing the GOT main unit to/from the panel.
Not doing so can cause the unit to fail or malfunction.
z
Be sure to shut off all phases of the external power supply used by the system before mounting or removing the communication unit, option function board or multi-color display board onto/from the GOT.
Not doing so can cause the unit to fail or malfunction.
z When installing the multi-color display board, wear an earth band etc. to avoid the static electricity.
Not doing so can cause a unit corruption.
CAUTION
z Use the GOT in the environment that satisfies the general specifications described in this manual.
Not doing so can cause an electric shock, fire, malfunction or product damage or deterioration.
z When mounting the GOT to the control panel, tighten the mounting screws in the specified torque range.
Undertightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a drop, short circuit or malfunction due to the damage of the screws or the GOT.
A-3
[MOUNTING PRECAUTIONS]
CAUTION
z When loading the communication unit to the GOT, fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range.
Under tightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a drop, failure or malfunction due to the damage of the screws or unit.
z When mounting the multi-color display board onto the GOT, tighten the mounting screws within the specified torque range.
Loose tightening may cause the unit and/or GOT to malfunction due to poor contact.
Overtightening may damage the screws, unit and/or GOT; they might malfunction.
z Push the option function board onto the corresponding connector until it clicks, so that it will be secured firmly.
z Push the multi-color display board onto the corresponding connector so that it will be secured firmly.
z When inserting a CF card into the GOT, push it into the insertion slot until the
CF card eject button will pop out.
Failure to do so may cause a malfunction due to poor contact.
z When inserting/removing a CF card into/from the GOT, turn the CF card access switch off in advance.
Failure to do so may corrupt data within the CF card.
z When removing a CF card from the GOT, make sure to support the CF card by hand, as it may pop out.
Failure to do so may cause the CF card to drop from the GOT and break.
[WIRING PRECAUTIONS]
DANGER
z Be sure to shut off all phases of the external power supply used by the system before wiring.
Failure to do so may result in an electric shock, product damage or malfunctions.
A-4
[WIRING PRECAUTIONS]
CAUTION
z Please make sure to ground FG terminal and LG terminal of the GOT power supply section by applying Class D Grounding (Class 3 Grounding Method) or higher which is used exclusively for the GOT.
Not doing so may cause an electric shock or malfunction.
z Terminal screws which are not to be used must be tightened always at torque
0.5 to 0.8 N•m.
Otherwise there will be a danger of short circuit against the solderless terminals.
z Use applicable solderless terminals and tighten them with the specified torque.
If any solderless spade terminal is used, it may be disconnected when the terminal screw comes loose, resulting in failure. z Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product.
Not doing so can cause a fire or failure.
z Tighten the terminal screws of the GOT power supply section in the specified torque range. Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of the screws or the GOT.
z Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT. Not doing so can cause a fire, failure or malfunction.
z Plug the bus connection cable by inserting it into the connector of the connected unit until it "clicks".
After plugging, check that it has been inserted snugly.
Not doing so can cause a malfunction due to a contact fault.
z Plug the communication cable into the connector of the connected unit and tighten the mounting and terminal screws in the specified torque range.
Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.
A-5
[TEST OPERATION PRECAUTIONS]
DANGER
z Before performing the test operations of the user creation monitor screen
(such as turning ON or OFF bit device, changing the word device current value, changing the settings or current values of the timer or counter, and changing the buffer memory current value), read through the manual carefully and make yourself familiar with the operation method.
During test operation, never change the data of the devices which are used to perform significant operation for the system.
False output or malfunction can cause an accident.
[STARTUP/MAINTENANCE PRECAUTIONS]
DANGER
z When power is on, do not touch the terminals.
Doing so can cause an electric shock or malfunction.
z
Connect the battery correctly.
Do not discharge, disassemble, heat, short, solder or throw the battery into the fire.
Incorrect handling may cause the battery to generate heat, burst or take fire, resulting in injuries or fires z
Before starting cleaning or terminal screw retightening, always switch off the power externally in all phases.
Not switching the power off in all phases can cause a unit failure or malfunction.
Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit.
A-6
[STARTUP/MAINTENANCE PRECAUTIONS]
CAUTION
z Do not disassemble or modify the unit.
Doing so can cause a failure, malfunction, injury or fire.
z Do not touch the conductive and electronic parts of the unit directly.
Doing so can cause a unit malfunction or failure.
z The cables connected to the unit must be run in ducts or clamped.
Not doing so can cause the unit or cable to be damaged due to the dangling, motion or accidental pulling of the cables or can cause a malfunction due to a cable connection fault.
z When unplugging the cable connected to the unit, do not hold and pull the cable portion.
Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault.
z Do not drop the module or subject it to strong shock. A module damage may result.
z Do not drop or give an impact to the battery mounted to the unit.
Doing so may damage the battery, causing the battery fluid to leak inside the battery.
If the battery is dropped or given an impact, dispose of it without using.
[STARTUP/MAINTENANCE PRECAUTIONS]
CAUTION
z Before touching the unit, always touch grounded metals, etc. to discharge static electricity from human body, etc.
Not doing so can cause the unit to fail or malfunction.
A-7
[BACKLIGHT CHANGING PRECAUTIONS]
DANGER
z Before changing the backlight, always switch off the GOT power externally in all phases (when the GOT is connected to the bus, the PLC CPU power must also be switched off externally in all phases) and remove the GOT from the control panel.
Not switching the power off in all phases may cause an electric shock.
Not removing the unit from the control panel can cause injury due to a drop.
CAUTION
z
When replacing the backlight, use the gloves.
Otherwise, it may cause you to be injured.
z Start changing the backlight more than 5 minutes after switching the GOT power off.
Not doing so can cause a burn due to the heat of the backlight.
[DISPOSAL PRECAUTIONS]
CAUTION
z When disposing of the product, handle it as industrial waste.
[TRANSPORTATION PRECAUTIONS]
CAUTION
z When transporting lithium batteries, make sure to treat them based on the transport regulations.
(Refer to GT15 User’s Manual for details of the regurated models.) z Make sure to transport the GOT main unit and/or relevant unit(s) in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the GT15 User's Manual, as they are precision devices.
Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
A-8
REVISIONS
Print Date
Jul., 2004
Oct., 2004
Jan., 2005
* The manual number is noted at the lower right of the top cover.
*Manual Number Revision
IB(NA)-0800305-A First edition
IB(NA)-0800305-B Partial correction
Section 3.2, Section 6.3.4
Partial addition
Section 2.1, Section 3.3,
Section 3.4, Section 4.2,
Section 4.3
IB(NA)-0800305-C Parial addition
Section 2.1, Section 2.2,
Section 2.3, Section 3.2,
Section 4.3, Section 5.1
This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual.
© 2004 MITSUBISHI ELECTRIC CORPORATION
A-9
CONTENTS
2.1 Part Names and Settings of the GT1585 ................................................. 2
2.2 Part Names and Settings of the GT1575 ................................................. 4
2.3 Part Names and Settings of the GT1565 ................................................. 6
3.3 Power Supply Specifications ................................................................. 13
4.1 Control Panel Inside Dimensions for Mounting GOT ............................. 17
4.4 Control Panel Inside Temperature and Mounting Angle ........................ 19
5.3 Wiring of Connection Cables ................................................................. 24
5.5 Power Terminal Connection .................................................................. 27
6.3 Battery Voltage Low Detection and Battery Replacement ..................... 30
6.3.2 Battery Specifications ................................................................... 30
6.3.3 Battery Replacement Procedure ................................................... 30
A-10
Manuals
The following shows manuals relevant to this product.
Detailed Manual
GT15 User's Manual
Manual name
(Option)
Manual Number
(Type code)
SH-080528ENG
(1D7M23)
Relevant Manual
For relevant manuals, refer to the PDF manual stored within the drawing software used.
Product Components
The GOT product package includes the following:
GOT
Installation fitting
Fixing screw(Plastic)
*1
Item name
*1 Spare for the plastic fixing screw of the GOT.
Quantity
1
4
1
A-11
1. Features
(1) Improved monitoring performance and connectivity to FA devices
• Using of TFT color liquid crystal display (high intensity, wide angle view and high definition type) provides clear full-color display and displays small characters clearly. (Displays digital images of BMP and other formats in 65536 colors.)
• Provides multi-language display function based on Unicode2.1
True Type font and high-speed drawing of beautiful text.
• High speed monitoring through high speed communication at maximum of 115.2kbps.
• High speed display and high speed touch switch response.
(2) More efficient GOT operations including screen design, startup, adjustment, management and maintenance works
• 9MB user memory is included as standard. (Memory capacity can be expanded up to 57MB by increasing the option memory)
• CF card interface is included as standard
• Font installation is available to increase the system fonts.
• Combined use of 4 types of alarms (system alarm, user alarm list, alarm history, floating alarm) realizes more efficient alarm notification.
• Maintenance report function is available that measures the backlight energization time and notifies of maintenance time.
(3) Enhanced support of FA device setup tools
• Transferring or monitoring the sequence programs using the personal computer connected to GOT, during direct connection to Q,
QnA, A or FX series PLC CPU, or computer link connection to A,
QnA or Q series (FA Transparent function).
• The USB connector is positioned on the GOT front. This enables the system startup to be performed more efficiently using FA device startup tool, and eliminates the necessity of indirect works
(opening and closing the control panel, cable replacement, cable rewiring) in order to improve the working efficiency.
1
2. Part Names
2.1 Part Names and Settings of the GT1585
16)
2) 3)
1)
4)
14)
5)
GOT Rear face
7) 13)
6)
8)
15)
9)
10)
11) 12)
2
No.
1)
2)
3)
4)
5)
Name
POWER LED
Display screen
Touch key
USB interface
RS232 interface
Description
Lit in green: Power is correctly supplied
Lit in orange: Screen saving
Blinks in orange/green: Blown back light bulb
Not lit: Power is not supplied
Displays the Utility and the user creation screen.
For operating touch switches in the Utility and the user creation screen
For connecting a personal computer
(Connector type: MINI-B)
For connecting a personal computer, bar code reader or communicating with PLCs
(Connector type: D sub 9-pin)
Power input terminal, LG terminal, FG terminal 6) Power terminal
7)
Extension module interface
8) CF card interface
For installing a communication module
9)
10)
CF card access LED
CF card access switch
For installing a CF card
Lit: CF card accessed
Not lit: CF card not accessed
Used for stopping the access to the CF card before removing the CF card from the GOT
ON: CF card being accessed
(CF card removal prohibited)
OFF: CF card not accessed
(CF card removal possible)
11)
12)
13)
Optional function board interface
Reset switch
For installing the optional function board
Multi-color display board interface
For installing the multi-color display board
Hardware reset switch
(Inoperative for bus connection)
14)
Hole for unit installation fitting
15) Battery holder
16) Human sensor
Hole for inserting the unit installation fitting
Houses the battery.
Sensor that detects human movement.
3
2.2 Part Names and Settings of the GT1575
2) 3)
1)
4)
14)
5)
GOT rear face
7) 13)
6)
8)
15)
9)
10)
11) 12)
4
No.
1)
2)
3)
4)
5)
Name
POWER LED
Display screen
Touch key
USB interface
RS232 interface
Description
Lit in green: Power is correctly supplied
Lit in orange: Screen saving
Blinks in orange/green: Blown back light bulb
Not lit: Power is not supplied
Displays the Utility and the user creation screen.
For operating touch switches in the Utility and the user creation screen
For connecting a personal computer
(Connector type: MINI-B)
For connecting a personal computer, bar code reader or communicating with PLCs
(Connector type: D sub 9-pin)
Power input terminal, LG terminal, FG terminal 6) Power terminal
7)
Extension module interface
8) CF card interface
For installing a communication module
9)
10)
CF card access LED
CF card access switch
For installing a CF card
Lit: CF card accessed
Not lit: CF card not accessed
Used for stopping the access to the CF card before removing the CF card from the GOT
ON: CF card being accessed
(CF card removal prohibited)
OFF: CF card not accessed
(CF card removal possible)
11)
12)
13)
Optional function board interface
Reset switch
For installing the optional function board
Multi-color display board interface
For installing the multi-color display board
Hardware reset switch
(Inoperative for bus connection)
14)
Hole for unit installation fitting
15) Battery holder
Hole for inserting the unit installation fitting
Houses the battery.
5
2.3 Part Names and Settings of the GT1565
2) 3)
1)
4)
14)
11)
5)
GOT rear face
7) 13)
6)
8)
9)
10)
15)
12)
6
No.
1)
2)
3)
4)
5)
Name
POWER LED
Display screen
Touch key
USB interface
RS232 interface
Description
Lit in green: Power is correctly supplied
Lit in orange: Screen saving
Blinks in orange/green: Blown back light bulb
Not lit: Power is not supplied
Displays the Utility and the user creation screen.
For operating touch switches in the Utility and the user creation screen
For connecting a personal computer
(Connector type: MINI-B)
For connecting a personal computer, bar code reader or communicating with PLCs
(Connector type: D sub 9-pin)
Power input terminal, LG terminal, FG terminal 6) Power terminal
7)
Extension module interface
8) CF card interface
For installing a communication module
9)
10)
CF card access LED
CF card access switch
For installing a CF card
Lit: CF card accessed
Not lit: CF card not accessed
Used for stopping the access to the CF card before removing the CF card from the GOT
ON: CF card being accessed
(CF card removal prohibited)
OFF: CF card not accessed
(CF card removal possible)
11)
12)
13)
Optional function board interface
Reset switch
For installing the optional function board
Multi-color display board interface
For installing the multi-color display board
Hardware reset switch
(Inoperative for bus connection)
14)
Hole for unit installation fitting
15) Battery holder
Hole for inserting the unit installation fitting
Houses the battery.
7
3. Specifications
3.1 General Specifications
Item
Operating ambient temperature
Display section
Other than display section
Storage ambient temperature
Operating ambient humidity
Storage ambient humidity
Specifications
0 to 50°C
0 to 55°C
-20 to 60°C
10 to 90% RH, non-condensing
10 to 90% RH, non-condensing
Vibration resistance
Shock resistance
*1
Operating atmosphere
Operating altitude
*2
Installation location
Overvoltage category
*3
Pollution degree
*4
Cooling method
Frequency Acceleration
Halfamplitude
Sweep
Count
Conforms to JIS
B3502 and
IEC61131
-2
Under intermittent vibration
Under continuous vibration
5 to 9Hz
9 to
150Hz
5 to 9Hz
9 to
150Hz
-
9.8m/s
-
4.9m/s
2
2
3.5mm
-
1.75mm
-
10 times each in X,
Y and Z directions
Conforms to JIS B3502, IEC 61131-2 (147 m/s
2
, 3 times each in X, Y and Z directions)
No corrosive gas
2000 m (6562 ft) max.
Inside control panel
II or less
2 or less
Self-cooling
8
*1 When using the MELSECNET/10 communication unit (GT15-
75J71LP23-Z, GT15-75J71BR13-Z) or CC-Link communication unit
(GT15-75J61BT13-Z), refer to the manual of the communication unit you use. (Differs with the specification of GOT.)
*2 Do not use or store the GOT under pressure higher than the atmospheric pressure of altitude 0m (0ft.). Failure to observe this instruction may cause a malfunction.
*3 This indicates the section of the power supply to which the equipment is assumed to be connected between the public electrical power distribution network and the machinery within the premises.
Category II applies to equipment for which electrical power is supplied from fixed facilities.
The surge voltage withstand level for up to the raged voltage of 300
V is 2500 V.
*4 This index indicates the degree to which conductive material is generated in the environment where the equipment is used.
In pollution degree 2, only non-conductive pollution occurs but temporary conductivity may be produced due to condensation.
9
3.2 Performance Specifications
Display section
*1
Backlight
Touch panel
Item
Type
Screen size
Resolution
Display size
Display character
Display color
Display angle
GT1585-STBA GT1575-STBA GT1575-VTBA GT1565-VTBA
TFT color liquid crystal
12.1”
800 × 600 dots
Specifications
10.4” 8.4"
640 × 480 dots
246(9.69)(W) ×
184.5(7.26)(H)
[mm](inch)
211(8.31)(W)
× 158(6.22)(H)[mm](inch)
16-dot standard font:
50 characters × 37 lines
12-dot standard font:
66 characters × 50 lines
171(6.73)(W) ×
128(5.04)(H)
[mm](inch)
16-dot standard font:
40 characters × 30 lines
12-dot standard font:
53 characters × 40 lines
256color/65536color *2
Left/Right:
60 degrees
Top :
40 degrees
Bottom :
50 degrees
Left/Right:
50 degrees
Top :
35 degrees
Bottom :
45 degrees
Left/Right/Top/
Bottom:
85 degrees
Left/Right:
65 degrees
Top :
50 degrees
Bottom :
60 degrees
Intensity of LCD only
Intensity adjustment
350 [cd/m
2
] 280 [cd/m
2
]
8-level adjustment
380 [cd/m
2
]
Life *3
Life
Number of touch keys
Key size
Number of objects that can be simultaneously touched
Life
Approx. 50,000 h
(Operating ambient temperature
: 25
°
C)
Approx. 41,000 h
(Operating ambient temperature
: 25
°
C)
Cold cathode fluorescent tube (replaceable) backlight shutoff detection function is included.
Backlight off/screen saving time can be set.
Approx. 40,000 h or longer
(Time when display luminance reaches 50% at the operating ambient temperature of 25
°
C)
1,900 objects/screen
(Matrix structure of 38 lines x 50 columns)
1,200 objects/screen
(Matrix structure of 30 lines x 40 columns)
Minimum 16 × 16 dots (per key)
Maximum of 2 objects
1 million times or more (operating force 0.98N max.)
10
Human
Sensor
Item
Detection length
Detection range
None
Specifications
GT1585-STBA GT1575-STBA GT1575-VTBA GT1565-VTBA
1(39.37)
[m](inch)
None
Left/Right/
Top/Bottom:
70 degrees
Memory
*4
Detection delay time
C drive
Life (Number of write times)
0 to 4s None
Built-in flash memory 9Mbytes (for storing project data and OS)
100,000 times
Battery
Built-in interface
Backup target
Life
RS-232
USB
CF card
GT15-BAT lithium battery (Option)
Clock data and maintenance time notification data
Approx. 5 years
(Operatomh ambient temperature of 25
°
C)
RS-232, 1ch
Transmission speed :115,200/57,600/38,400/19,200/9,600
/4,800 bps
Connector shape
Application connection and PC communication
(Project data upload/download, OS installation, transparent function)
:D-sub 9-pin (Male)
:PLC communication, bar code reader
USB (Full Speed 12Mbps), 1ch
Connector shape : Mini-B
Application : PC communication (screen data upload/ download, OS installation and FA transparent function)
Compact flash slot, 1ch
Connector shape : TYPE I
Application : Data transfer, data storage
Option function board
Multi-color display board
Communication unit/Option unit
Buzzer output
Environmental protective structure
External dimensions
(Excluding USB environmental protection cover)
For option function board mounting, 1ch
For multi-color display board mounting, 1ch
For communication unit/option unit mounting, 1ch
316(12.44)(W)
× 242(9.53)(H)
× 52(2.05)(D)
[mm](inch)
Single tone (tone length adjustable)
IP67 (JEM1030) (front section)
303(11.93)(W) × 214(8.43)(H)
× 49(1.93)(D)[mm](inch)
*5
241(9.49)(W) ×
190(7.48)(H)
× 52(2.05)(D)
[mm](inch)
11
Weight
Item
Panel cutting dimensions
Specifications
GT1585-STBA GT1575-STBA GT1575-VTBA GT1565-VTBA
302(11.89)(W)
× 228(8.98)(H)
[mm](inch)
289(11.38)(W)
× 200(7.87)(H)[mm](inch)
227(8.94)(W)
× 176(6.93)(H)
[mm](inch)
2.6 kg
(mounting fixtures are not included)
2.3 kg
(mounting fixtures are not included)
GT Designer2 Version2.04E or later
2.2 kg
(mounting fixtures are not included)
1.8 kg
(mounting fixtures are not included)
GT Designer2 Version2.00A or later
Compatible software package
*1 Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display comprises of a great number of display elements. Please note that these dots appear due to its characteristic and are not caused by product defect.
*2 Full-color display (66536 colors) is available when the multi-color display board is mounted.
*3 The GOT screen saving/backlight off function prevents images from becoming permanently etched on the display screen and increases the backlight life.
*4 ROM in which new data can be written without deleting the written data.
*5 Compliant with IP67 when the USB environmental protection cover is attached. Not compliant when a USB cable is connected. Note that this does not guarantee all users' operation environment.
12
3.3 Power Supply Specifications
Item
Specifications
GT1585-STBA GT1575-STBA, GT1575-VTBA, GT1565-VTBA
Input power supply voltage
Input frequency
Input max. apparent power
Power consumption
At backlight off
AC100 to 240V(+10% -15%)
50/60Hz ± 5%
90VA (maximum load)
Inrush current
28W or less
45A or less (4ms)
(maximum load)
26W or less
20W or less
40A or less (4ms)
(maximum load)
Permissible instantaneous power failure time
Noise immunity
20ms (100VAC or longer)
By noise simulator of 1,500Vp-p noise voltage, 1
25 to 60Hz noise frequency
µ s noise width and
Dielectric withstand voltage
Insulation resistance
Applicable wire size
Applicable solderless terminal
Applicable tightening torque (Terminal block terminal screw)
1500VAC for 1 minute across AC external terminals and earth
10M
Ω
or larger by insulation resistance tester
0.75 to 2 [mm
2
]
Solderless terminal for M3 screw RAV1.25-3, V2-S3.3, V2-N3A,
FV2-N3A
0.5 to 0.8 [N•m]
Remarks
Operation at momentary power failure
• If an instantaneous power failure occurs in the power supply and continues for more than the permissible period, the GOT will be reset.
• Make sure to power on the unit more than 5 seconds after power-off.
13
3.4 External Dimensions
(1) GT1585-STBA
316(12.44)
263(10.35)
14
250(9.84)
301(11.85)
Unit: mm (inch)
(2) GT1575-STBA GT1575-VTBA
303 (11.93)
252 (9.92)
222 (8.74)
288 (11.34)
Unit: mm (inch)
15
(3) GT1565-VTBA
241 (9.49)
175.5 (6.91)
175.5 (6.91)
226 (8.90)
Unit: mm (inch)
16
4. Installation
4.1 Control Panel Inside Dimensions for Mounting GOT
Mount the GOT onto the control panel while considering the control panel inside dimensions.
POINT
Applicable cable
Some cables may need to be longer than the specified dimensions when connecting to the GOT.
Therefore, consider the connector dimensions and bending radius of the cable as well for installation.
4.2 Panel Cutting Dimensions
Make holes in the panel according to the dimensions list below.
Also, ensure 10mm spaces in upper and lower parts of the panel for mounting fixtures.
A
* Panel thickness: 2 to 4 mm
or less
GOT
GT1585
GT1575
GT1565
A [mm](inch)
302(11.89)
(+2(0.08),0(0))
289(11.38)
(+2(0.08),0(0))
227(8.94)
(+2(0.08),0(0))
B [mm](inch)
228(8.98)
(+2(0.08),0(0))
200(7.87)
(+2(0.08),0(0))
176(6.93)
(+2(0.08),0(0))
17
4.3 Mounting Position
When mounting the GOT, the following clearances must be left from the other device.
C D E
Panel thickness: 2 to 4mm
(0.08 to 0.16inch)
A
B
C, D
E
Type
GOT or Bus connection unit is fitted
GT1585
50(1.97) or more
[14(0.55) or more]
GT1575
50(1.97) or more
[31(1.22) or more]
GT1565
50(1.97) or more
[36(1.92) or more]
RS-422 Conversion unit is fitted 51(2.01) or more 68(2.68) or more 73(2.87) or more
Ethernet communication unit,
MELSECNET/10 communication unit (coaxial),
CC-Link communication unit fitted.
50(1.97) or more
[10(0.39) or more]
MELSECNET/10 communication unit (optical) fitted.
50(1.97) or more
[26(1.02) or more]
50(1.97) or more
[10(0.39) or more]
50(1.97) or more
[43(1.69) or more]
80(20) or more
50(20) or more
50(1.97) or more
[10(0.39) or more]
50(1.97) or more
[48(1.89) or more]
100(20) or more
Unit: mm (inch)
The values enclosed in parenthesis apply to the case where no other equipment generating radiated noise (such as a contactor) or heat is installed. However, keep the ambient temperature of the GOT to 55°C or lower even in such a case.
The required lead-in allowance for cables may be larger than the size of
A above depending on the unit or cable used.
For the lead-in allowance for cables at the bottom of the GOT, refer to the following.
Connected manual of GOT1000 series
18
4.4 Control Panel Inside Temperature and Mounting Angle
When mounting the main unit to a control panel or similar, set the display section as shown below.
• When the temperature inside the control panel is 40 to 55°C or less, the mounting angle should be in the range 60 to 105 degrees.
GOT
105
Display section
60
Control panel, etc.
• The GOT will be deteriorated earlier if it is used at the mounting angle other than the above. Therefore, the temperature inside the control panel should be within 40°C.
19
4.5 Installation Procedure
The GOT is designed to be embedded into a panel.
Mount the GOT by following the procedure below.
For panel cutting dimensions, refer to Section 4.2.
Note that the panel thickness should be within 4mm.
(1) Placing into the panel
Place the GOT into the panel from the front.
No
1)
2)
Name
GOT
Mounting hole
1)
2)
(2) Fixing the GOT
Insert mounting fixtures
(included with GOT) into module fixing holes and tighten mounting screws in four upper/lower parts until the GOT will be fixed.
Magnified illustration
No
1)
2)
Name
Mounting fixture
Mounting screw
1)
2)
Tighten mounting screws in the torque range of 0.36 to
0.48N•m.
(Failure to do so may distort the panel and make a surface waviness on the protective sheet.)
(3) A protection film is attached on the display section of GOT prior to shipment.
Remove the film when the installation is compelted.
20
5. Wiring
5.1 Wiring Precautions
DANGER
z Before starting wiring, always switch off the GOT power externally in all phases.
Not doing so may cause an electric shock, product damage or malfunction.
CAUTION
z Please make sure to ground FG terminal and LG terminal of the GOT power supply section by applying Class D Grounding (Class 3 Grounding Method) or higher which is used exclusively for the GOT.
Not doing so may cause an electric shock or malfunction.
z Correctly wire the GOT power supply section after confirming the rated voltage and terminal arrangement of the product.
Not doing so can cause a fire or failure.
z
Tighten the terminal screws of the GOT power supply section in the specified torque range. Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of the screws or the GOT.
z Exercise care to avoid foreign matter such as chips and wire offcuts entering the GOT. Not doing so can cause a fire, failure or malfunction.
This section describes wiring to the GOT power supply section.
For the connection with PLC CPU or others, refer to the following.
GOT1000 Series Connection Manual
Remarks
General preventive measures against noise
There are two kinds of noises: Radiated noise that is transmitted into the air and conductive noise that is directly transmitted through connected lines. In noise countermeasures, the both two types of noise should be taken into account. As the noise countermeasures, there are the following three methods.
21
(1) Protecting against noise
(a) Keep signal lines away from possible noise sources such as power cables or high-power driving circuits.
(b) Shield signal lines.
(2) Reducing generated noise
(a) Use a noise filter, etc. to reduce the noise generated from high-power motor drive circuits.
(3) Releasing noise to the ground
(a) Make sure to connect the ground cable to the ground.
(b) Use a ground cable as short and thick as possible to lower its impedance.
(c) Separate the grounding between power and control systems.
22
5.2 Power Supply Wiring
• Make wiring connections to the power supply, I/O equipment and power equipment separately by system as shown below.
When frequent noise is identified, connect an isolation transformer.
Main power GOT power
Isolation transformer
GOT
T1
I/O power
I/O equipment
Main circuit power
Main circuit equipment
Wiring diagram for power supply
• Twist 100V AC, 200V AC or 24V DC cable as closely as possible and connect the cable between modules at the minimum length.
Also, use the thickest cable as possible (0.75 to 2mm
2
) to minimize the voltage drop.
Use M3 solderless terminals and securely tighten them with a tightening torque of 0.5 to 0.8N
• m so that no problem will result.
• Separate the 100V AC, 200V AC or 24V DC cable from the main circuit lines (high voltage, large current) and/or I/O signal lines.
Keep a distance of 100mm or more.
23
• As measures against surge due to lightning, connect a lightning surge absorber as shown below.
Lightning surge absorber connection
AC
GOT
I/O equipment
E2
E1
Lightning surge absorber
POINT
1. Separate the grounding of the lightning surge absorber (E1) from the grounding of the GOT (E2).
2. Select an appropriate lightning surge absorber so that the supply voltage does not exceed the maximum allowable circuit voltage of the surge absorber even when it rises to the maximum.
5.3 Wiring of Connection Cables
Keep the connection cables away from the main circuit lines (high voltage, large current) or I/O signal lines.
When using GT15-C EXSS-1 or GT15C BS, perform the grounding in the following steps.
(1) When using GT15-C EXSS-1
Not connected
PLC
GOT
3)
(GT15-C BS)
OUT IN
FG
LG
N
L
(GT15-EXCNB)
L N LG FG
5)
2SQ cables to
FG terminals,
28cm or less
6)
4)
1)
2)
1) Connect the LG and FG terminals of the terminal block on the GOT unit power and ground them with a cable.
2) Use the GT15-C BS's FG cable of 28cm or less.
3) Do not connect the GT15-EXCNB's FG ground cable.
4) Connect the GT15-C BS's FG cable on the GOT side to FG of the
GOT unit power's terminal block.
24
5) Connect the GT15-C BS's FG cable on the PLC side to FG of the
PLC's power supply module.
6) Connect the LG and FG terminals of the terminal block on the PLC and ground them with a cable.
(2) When using GT15-C BS
For the both side GOTs, connect the LG and FG terminals of the terminal block on the GOT unit power and ground them with a cable.
5.4 Grouding
Make sure to carry out the followings for grounding.
• Carry out the independent grounding if possible.
• If the independent grounding is impossible, carry out the shared grounding as shown in fig.2) below.
GOT
Grounding
Other device
GOT
Grounding
Other device
GOT
Other device
(1) Independent ground
...... Best condition
(2) Shared grounding
...... Good condition
(3) Common grounding
...... Not allowed
• Use the cable of 2mm
2
or more for grounding.
Set the grounding point closer to the GOT to make the grounding cable short as possible.
(1) Example of independent grounding
Power equipment
(servo, etc.)
PLC
Connection cable
CN1A CN1B
CN 2C N3
FG
FG
LG
FG
LG
GOT
Ground terminal block
Panel grounding
Ground terminal block
Grounding for power system
Grounding for control system
25
* Ground the control system, especially modules communicating each other, to one end.
(2) Example of shared grounding
Power equipment
(servo, etc.)
PLC
Connection cable
CN1A CN1B
CN2C N3
FG
FG
LG
FG
LG
GOT
Panel grounding
Panel grounding
6.2mm or less
Use a short and thick cable as much as possible.
* Ground the system to one end.
Recommended terminal shape
3.2
Terminal screw
Solderless terminal
3.2
6.2mm or less
Terminal screw
Solderless terminal
When wiring one cable to one terminal
When wiring two cables to one terminal
Applicable solderless terminal RAV1.25- 3, V2- S3.3, V2- N3A, FV2- N3A
26
5.5 Power Terminal Connection
This section provides an example for connecting power cables and ground cables to the power terminals situated on the back of the GOT.
100/110V AC
AC
In the case of 100V AC
GOT
Fuse
INPUT
100-240VAC
(LG) (FG)
AD
DC
24V DC
GOT
INPUT
24VDC
(LG) (FG)
In the case of 24V DC
Ground cables
Grounding
POINT
1. For 100V AC, 200V AC or 24V DC cable, use the thickest cable as possible (0.75 to 2mm
2
) and start twisting them at the position closest to the connected terminals.
To prevent a short circuit due to loose screws, use the solderless terminal with insulation sleeve.
2. When connection is made between LG and FG terminals, be sure to connect them to the ground.
Otherwise, the system becomes susceptible to noise.
Since the LG terminal has potential equal to a half of the input voltage, touching the terminal may lead to an electric shock.
27
6. Maintenance and Inspection
6.1 Daily Inspection
Daily inspection items
No.
1
2
3
Inspection Item
GOT mounting status
Inspection
Method
Check for loose mounting screws.
Criterion
Securely mounted
Action
Retighten screws within the specified torque range.
Retighten terminal screws
Connection status
Loose terminal screws
Proximate solderless terminals
Usage status
Retighten screws with screwdriver
Visual check
Loose connectors
Visual check
Dirt on protection sheet
Foreign material attachment
Visual check
Visual check
Not loose
Proper intervals
Not loose
Not outstanding
Correct
Retighten connector fixing screws
Replace with new one
No foreign matter sticking
Remove, clean
For applicable protective sheet model or replacement procedure, refer to
GT15 User’s Manual.
28
6.2 Periodic Inspection
Yearly or half-yearly inspection items
The following inspection should also be performed when equipment has been moved or modified or the wiring changed.
No.
1
2
3
4
Inspection Item
Surroun ding environ ment
Ambient temperature
Ambient humidity
Atmosphere
Power supply voltage check
Inspection
Method
100 to 240VAC
Measure voltage across terminals.
Criterion
Make measurement with thermometer or hygrometer
Measure corrosive gas
Display section
Other portions
10 to 90%RH
0 to 40
°
C
0 to 55
°
C
No corrosive gas
85AC to 242V
Move module
Visual check
Should be mounted firmly
No dirt, foreign matter sticking
Looseness
Mountin g status
Connecti on status
Dirt, foreign matter
Loose terminal screws
Proximate solderless terminals
Loose connectors
Retighten screws with screwdriver
Not loose
Visual check
Visual check
Proper intervals
Not loose
5 Battery
Check "GOT internal battery voltage status" in
"Time setting & display" of the
Utility. (Refer to the GT15 User's
Manual.)
No alarm appears
Action
For use in control panel, temperature inside control panel is ambient temperature
Change supply power
Retighten screws
Remove, clean
Retighten terminal screws
Correct
Retighten connector fixing screws
Replace with new battery when the current battery has reached the specified life span, even if battery voltage low is not displayed.
29
6.3 Battery Voltage Low Detection and Battery Replacement
Battery is used to store the current time or maintenance time notification data.
It is recommended to replace battery periodically.
6.3.1 Applicable Battery
The following battery is applicable for GT15 .
Model Description
GT15-BAT Battery for backup of clock data and maintenance time notification data.
6.3.2 Battery Specifications
Item
Type
Initial voltage
Nominal current
Storage life
Total power stoppage time
Application
Specifications
Magnesium manganese dioxide lithium primary battery
3.0V
1800mAh
Approx.5 years (Operating ambient temperature of 25°C)
Refer to Section 6.3.4.
For backup of clock data and maintenance time notification data.
6.3.3 Battery Replacement Procedure
Replace battery periodically by referring to Section 6.3.4 Battery life.
BATTERY
(1) Keep the GOT power supply on for 10 minutes or more, and turn it off.
(Executes step 2 to 6 within 5 minutes of powering the GOT power supply off.)
(2) Remove the battery folder form the GOT backside.
Battery holder
(GOT backside)
(3) Remove the old battery from the folder and disconnect the connector.
(4) Connect the new battery to the connector.
(5) Insert the battery into the folder and set it into the GOT backside.
30
(6) Turn the GOT power supply on.
(7) Check if the battery condition is normal within the utility.
For details, refer to the GT15 User’s Manual.
POINT
1. Precautions after battery replacement
Make sure to turn on the GOT power supply once upon completion of battery replacement.
Failure to do so may decrease the battery life.
2. When the bus connection unit (GT15-75ABUSL/GT15-75ABUS2L) is connected to GT1565
Before installing or replacing the battery, disconnect the bus connection cable.
(When connecting or disconnecting the bus connection cable, be sure to power off the GOT and PLC.)
6.3.4 Battery Life
Life span of the battery set in the GOT is shown below.
GOT model
Operating ambient temperature of 0 to
45°C
Battery life
Operating ambient temperature of 45 to
55°C
Data backup time after detection of battery voltage low
*
GT1585
GT1575
GT1565
5 years 3 years 14 days
*: In the following conditions, the data backup time is 5 minutes after the power supply is turned off.
• The battery connector is disconnected.
• The battery lead is disconnected.
POINT
Battery life and replacement time
1. Battery life reference: Approx.5 years in actual use (Operating ambient temperature of 25°C)
Battery replacement time reference: 4 to 5 years
Calculate the natural discharge amount of the battery, as necessary.
2. Check if the battery condition is normal within the utility.
For details, refer to the GT15 User’s Manual.
31
MEMO
32
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be the cause of
Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by
Mitsubishi; damages to products other than Mitsubishi products; and to other duties.
For safe use
• This product has been manufactured as a general-purpose part for general industries, and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.
• Before using the product for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.
• This product has been manufactured under strict quality control. However, when installing the product where major accidents or losses could occur if the product fails, install appropriate backup or failsafe functions in the system.
Country/Region Sales office/Tel
Brazil
U.K
Italy
Germany
500 Corporate Woods Parkway Vernon
MELCO-TEC Rep. Com.e Assessoria
Rua Correia Dias, 184,
Edificio Paraiso Trade Center-8 andar
Paraiso, Sao Paulo, SP Brazil
Mitsubishi Electric Europe B.V. German
Branch
Gothaer Strasse 8 D-40880 Ratingen,
GERMANY
Mitsubishi Electric Europe B.V. UK
Branch
Travellers Lane, Hatfield, Herts., AL10
8XB,UK
Mitsubishi Electric Europe B.V. Italian
Branch
Centro Dir. Colleoni, Pal. Perseo-Ingr.2
Via Paracelso 12, 20041 Agrate B.,
Country/Region Sales office/Tel
Hong Kong Ryoden Automation Ltd.
10th Floor, Manulife Tower, 169 Electric
Road, North Point, HongKong
China Ryoden Automation Shanghai Ltd.
Instrumentation Plaza 103 Cao Bao Rd.
Shanghai 200233 China
+86-21-6120-0808
Taiwan Setsuyo Enterprise Co., Ltd.
6F., No.105 Wu-Kung 3rd.RD, Wu-Ku
Korea
Singapore
Mitsubishi Building
Thailand
HAN NEUNG TECHNO CO.,LTD.
1F Dong Seo Game Channel Bldg.,
Mitsubishi Electric Asia Pte, Ltd.
307 Alexandra Road #05-01/02,
F. A. Tech Co.,Ltd.
Tower 2,Floor 17-18 Rama 3 Road,
Spain Mitsubishi Electric Europe B.V. Spanish
Branch
Carretera de Rubi 76-80
08190 Sant Cugat del Valles,
France Mitsubishi Electric Europe B.V. French
Branch
25 Boulevard des Bouvets, F-92741
Indonesia
India
P.T. Autoteknindo SUMBER MAKMUR
Jl. Muara Karang Selatan Block a Utara
No.1 Kav. No.11 Kawasan Industri/
Pergudangan Jakarta - Utara 14440
Electronic Sadan NO:111 Unit No15,
South Africa Circuit Breaker Industries LTD.
Tripswitch Drive, Elandsfontein Gauteng,
Australia Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, PostalBag, No 2,
HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice.
Printed in Japan on recycled paper.
डाउनलोड
विज्ञापन