BRI Facilities

BRI Facilities

The procedures in this section provide the steps for programming the following options for Basic Rate Interface (BRI) facilities connected to a 800 NI-BRI module:

Service Profile Identifier (SPID) and Directory Number (DN)

Timers

NOTES:

1.

The 800 NI-BRI module is only available in Release 4.0 and later.

2.

If you are adding BRI facilities to an existing system, clock synchronization

must be set correctly. To inspect or change these values, see “Clock

Synchronization” in “Lines and Trunks.”

Service Profile Identifier (SPID) and

Directory Number (DN)

Use this procedure to program the Service Profile Identifier (SPID) and Directory

Number (DN) for each BRI line in the system. Until these values are programmed for each line, the system will consider the BRI line inactive and the line will not initialize.

NOTE:

The system will not be forced idle when SPIDs are entered. However, if for some reason a SPID changes, the line must be idle (no active call on the line) in order to change the SPID.

Summary: Service Profile Identifier (SPID) and

Directory Number (DN)

Programmable by System manager

Mode

Idle Condition

Planning Form

Factory Setting

Valid Entries

Inspect

Key, Hybrid/PBX

Not required none

SPID: up to 20 digits (any combination of 0 to 9)

DN: up to 10 digits (any combination of 0 to 9)

No

Copy Option No

Console Procedure LinesTrunks ®

More

® BRI ® SPID/DN .

®

Dial line/trunk no.

® Enter ®

Dial SPID

® Enter ®

Dial DN

® Enter ® Exit ®

Exit

PC Procedure 4 ® u ® 8 ® 1 ®

Type line/trunk no.

® 0 ®

Type

SPID

® 0 ®

Type DN

® 0 ® 5 ® 5

Programming Procedures 4–185

BRI Facilities

Procedure: Service Profile Identifier (SPID) and

Directory Number (DN)

1

Console Display/Instructions

Select the Lines and Trunks menu.

Additional Information

2

3

_

System Programming:

Make a selection

System Extensions

SysRenumber Options

Operator Tables

LinesTrunks AuxEquip

Exit NightSrvce

>

Go to the second screen of the Lines and Trunks menu.

Lines and Trunks:

Make a selection

LS/GS/DS1

TIE Lines

PRI

Copy

TT/LS Disc

DID

Exit

RemoteAccss

Pools

Toll Type

>

Select BRI.

Press More .

Lines and Trunks:

Make a selection

HoldDiscnct LS-ID Delay

PrncipalUsr ClockSync

QCC Prior

QCC Oper

Exit

BRI

T1 Data NW

>

_

4

_

Select Service Profile Identifier (SPID) and Directory Number (DN).

BRI Lines:

Make a selection

SPID/DN

Timers

5

Exit Select SPID/DN .

Enter the line/trunk number ( nnn = 1 to 80).

SPID/DN:

Enter line number nnn

Backspace

Exit Enter Dial or type [ nnn ].

PC

4 u

8

1

Û

4–186 Programming Procedures

BRI Facilities

6

7

Console Display/Instructions

Erase the current SPID.

Line number xxx:

Enter SPID xxxxxxxxxxxxxxxxxxxx

Backspace

Exit Enter

Enter the new SPID.

xxx

Press Drop .

Additional Information

= line number selected in Step x.

Dial or type [ xxxxxxxxxxxxxxxxxxxx ].

8

9

Save your entry.

Select Enter .

Erase the current DN.

Line xxx:

Enter DN xxxxxxxxxx xxx = line number selected in Step x.

Backspace

Exit

Next

Enter

10 Enter the new DN.

Press Drop .

Dial or type [ xxxxxxxxxx ].

11 Save your entry.

Select Enter .

12 Return to the System Programming menu.

Select Exit three times.

PC

A + p

Û

0

A + p

Û

0

555

Timers

Use this procedure to set timer thresholds.

!

CAUTION:

The factory settings for these thresholds are standard and rarely need to be changed. If you are not sure of the correct timer and threshold settings for your BRI lines and trunks, check with your AT&T representative before you make a change. Incorrect settings can cause your BRI lines and trunks to malfunction.

If the network does not respond before the programmed time, the system takes the appropriate corrective action.

Programming Procedures 4–187

BRI Facilities

The timers are listed below.

■ T200 Timer.

acknowledgement of a message sent from the communication system to the network.

Minimum time that the link layer waits for an

■ T203 Timer.

Maximum time that the link layer can remain inactive.

■ T303 Timer.

Times the delay in network response when the communication system sends a setup message to initiate an outgoing call.

■ T305 Timer.

Times the delay in network response when the communication system sends a disconnect message to clear a call.

■ T308 Timer.

Times the delay in network response when the communication system sends a release message to clear a call.

NOTE:

If you enter an invalid timer value, you will hear an error beep and the value that was previously stored will be displayed on the screen.

Table 4–4 shows the factory setting for each timer and the valid range for each

threshold.

Summary: Timers

Programmable by System manager

Mode

Idle Condition

Planning Form

Factory Setting

Valid Entries

Inspect

Key, Hybrid/PBX

Not required

See Table 4–4

See Table 4–4

No

Copy Option No

Console Procedure LinesTrunks ®

More

® BRI ® Timers ®

Select timer

®

Drop

®

Dial no. of seconds or ms

® Enter ® Exit ® Exit

PC Procedure

4 ® u ® 8 ® 2 ®

Select timer

® A

+

P ®

Type no. of seconds or ms

® 0 ® 5 ® 5

4–188 Programming Procedures

BRI Facilities

Table 4–4. Timers

Timer/Counter Purpose

T200 Timer

T203 Timer

T303 Timer

T305 Timer

T308 Timer maximum response time 1000 ms maximum time

Set up timeout

Disconnect timeout

Release timeout

Factory Setting Valid Range

33 seconds

4 seconds

30 seconds

4 seconds

Increments

500 to 5000 ms 500 ms

10 to 255 sec

2 to 10 sec

2 to 60 sec

2 to 10 sec

1 sec

1 sec

1 sec

1 sec

Procedure: Timers

1

Console Display/Instructions

Select the Lines and Trunks menu.

2

3

Additional Information

_

System Programming:

Make a selection

System Extensions

SysRenumber Options

Operator Tables

LinesTrunks AuxEquip

Exit NightSrvce

>

Go to the second screen of the Lines and Trunks menu.

Lines and Trunks:

Make a selection

LS/GS/DS1

TIE Lines

PRI

Copy

TT/LS Disc

DID

Exit

RemoteAccss

Pools

Toll Type

>

Select BRI.

Press More .

Lines and Trunks:

Make a selection

HoldDiscnct LS-ID Delay

PrncipalUsr ClockSync

QCC Prior

QCC Oper

BRI

Exit

>

_

PC

4 u

8

Programming Procedures 4–189

BRI Facilities

4

_

Console Display/Instructions

Select Timers.

BRI Lines:

Make a selection

SPID/DN

Timers

Additional Information

5

35

Exit

_

_

_

_

Select the timer to change.

BRI Timer Settings:

Make a selection

T200 Timer

T203 Timer

T303 Timer

T305 Timer

Exit

>

T308 Timer

_

5 Erase the current setting.

6

7

8

(Display depends on timer/counter selected).

Backspace

Exit Enter Press Drop .

Enter the new setting (see Table 4–4).

Dial or type [ nnnn ].

Save your entry.

Select Enter .

Return to the System Programming menu.

Select Exit two times.

PC

2

A+P

Û

0

55

4–190 Programming Procedures