9. KEYBOARD FUNCTIONS
This chapter describes the GammaVision accelerator keys. The keys described in this section are grouped primarily according to location on the keyboard and secondarily by related function.
9.1. Introduction
Table 17 provides a quick reference to all of the GammaVision keyboard and keypad functions.
These accelerators are also illustrated in Fig. 300, and discussed in more detail in the remainder of the chapter.
The accelerators are available only in the GammaVision window. The title bar must be highlighted with the active title bar color (as set up in Windows Control Panel). In addition, the active cursor — or input focus — must be in one of the spectrum windows. Similar to other
Windows applications, the focus can be switched between GammaVision and other applications by clicking on the Windows Taskbar, pressing <Alt + Tab>, or, if the inactive window is visible, pointing with the mouse at some spot in the inactive window and clicking.
The multi-key functions, such as <Alt + 1> or <Shift +
6
>, are executed by holding down the first key (e.g., <Alt>, <Shift>, or <Ctrl>) while pressing the key that follows the “+” sign in the brackets, then releasing both keys simultaneously. Functions that use the keypad keys begin with the word Keypad, e.g., Keypad<5>.
As usual for any Windows application, the menus are accessed by clicking on them with the mouse, or by using the Alt key plus the key that matches the underlined letter in the menu item name. For example, the multi-key combination to activate the File menu is <Alt + F>.
Note that the GammaVision accelerator keys do not interfere with Windows menu operations or task switching. For example, when a menu is active (i.e., pulled down), the <
7
>/<
6
> and
<
8
>/<
9
> keys revert to their normal Windows functions of moving across the menu bar and scrolling up/down within a menu, respectively. As soon as the menu is closed, they behave as
GammaVision accelerators again.
9.2. Marker and Display Function Keys
9.2.1. Next Channel <
6
>/<
7
>
When not in rubber-rectangle mode, the right and left arrow keys move the marker by one displayed pixel in the corresponding direction. This might represent a jump of more than one spectral data memory channel, especially if the horizontal scale in channels is larger than the width in pixels of the window (see the discussion in Section 4.2).
375
GammaVision
®
v7 (A66-BW) 783620H / 1013
Table 17. Quick Reference to GammaVision Keyboard Commands.
Key
<
9
> or <F5>
<
8
> or <F6>
<
6
>
<
7
>
<
!
> or <F7>
<+> or <F8>
<Ctrl +
6
>
<Ctrl +
7
>
<Shift +
6
>
<Shift +
7
>
<Shift +
8
>
<Shift +
9
>
<Alt +
6
>
<Alt +
7
>
<PageUp>
<PageDown>
<Home>
<End>
<Ctrl + Fi>
<F2>
<F3>
<Shift + F3>
Function
Change vertical scale so spectrum peaks appear smaller (vertical zoom out).
Change vertical scale so spectrum peaks appear larger (vertical zoom in).
Move marker to higher channel.
Move marker to lower channel.
Narrow the horizontal scale.
Widen the horizontal scale.
Jump to next higher peak.
Jump to next lower peak.
Jump to next higher ROI. In rubber rectangle mode, shift rectangle right (to higher energy/channel) one pixel.
Jump to next lower ROI. In rubber rectangle mode, shift rectangle left (to lower energy/channel) one pixel.
Shift the Compare spectrum up. In rubber rectangle mode, shift rectangle up (away from baseline) one pixel.
Shift the Compare spectrum down. In rubber rectangle mode, shift rectangle down (toward baseline) one pixel.
Advance to next library entry.
Move back to previous library entry.
Jump to higher channel number in 1/16th-screen-width increments.
Jump to lower channel number in 1/16th-screen-width increments.
Jump to first channel of the full spectrum.
Jump to last channel of the full spectrum.
Select Detector i (i = 1 to 12, in pick list order).
Switch ROI bit control from OFF to SET to CLEAR.
In MCBs with ZDT Mode, switch between the two spectra stored in ZDT mode.
In Compare mode when comparing ZDT spectra, hold the initial spectrum in its current ZDT view (ERR or ZDT) and toggle the Compare spectrum between its ZDT views.
<F4> or <Alt + 6>
Switch between displaying selected Detector and buffer.
<F5> or <
9
>
Change vertical scale so spectrum peaks appear smaller (vertical zoom out).
<F6> or <
8
>
<F7> or <
!
>
Change vertical scale so spectrum peaks appear larger (vertical zoom in).
Change the horizontal scale so peaks appear narrower (horizontal zoom out)
<F8> or <+>
Change the horizontal scale so peaks appear wider (horizontal zoom in)
<Alt + F7>
Keypad<
!
>
Keypad<+>
Reset both horizontal and vertical scaling to view complete spectrum.
Zoom out.
Zoom in.
Keypad<5>
Keypad</>
Keypad<*>
Insert<Ins>
Center expanded display on cursor.
Switch between logarithmic and linear vertical scaling.
Switch to auto vertical scale.
Delete<Del>
<Alt + 1>
<Alt + 2>
Mark the peak region around the cursor as an ROI.
Clear the ROI.
Start acquisition in selected Detector.
<Alt + 3>
<Alt + 5>
Stop acquisition in selected Detector.
Clear data in selected Detector.
Copy data in the selected Detector to the buffer.
<Alt + 6> or <F4>
Switch between displaying selected Detector and buffer.
<Alt +
!
>
Decrease amplifier fine gain by smallest increment (where supported).
<Shift + Alt +
!
>
Decrease amplifier fine gain by several increments.
<Alt + +>
<Shift + Alt + +>
Increase amplifier fine gain by smallest increment.
Increase amplifier fine gain by several increments.
<PrintScreen>
Capture screen to Windows Clipboard.
376
783620H / 1013 9. KEYBOARD FUNCTIONS
Fig. 300. GammaVision Keyboard and Keypad Accelerators.
377