If the NT20 is used for the first time or if the screen data is ruined and the
NT20 cannot be normally started, the memory needs to be initialized.
The memory initialization is required in the cases described below.
• When the NT20 is used for the first time or when an error message indicating that the screen data is ruined etc. when the NT20 is started.
➡
Use the “Maintenance Mode” – “Init. Memory” in the System Menu.
• When the NT20 has made a buzzer sound and the screen has disappeared during the start-up or operation.
➡
Use the NT20 DIP SW2-1 “Screen data forced initialize Yes/No”.
When an error has occurred, the error messages such as “Screen data corrupted” will be displayed. For the error messages displayed on the screen,
refer to 7-2 Responding to Displayed Error Messages.
Note
Initializing the screen data memory will erase entire screen data registered in the NT20. Make sure that there are backup copies of the screen data on floppy disks before starting the initialization.
• Data of the NT20 to Be Initialized
Screen data
System memory
Memory tables
Mark data
Direct information
3-4-1 Initialization by Using the System Menu
Initialize the screen data memory by following the procedure given below.
Select “Maintenance Mode”.
[ SYSTEM MENU ]
Quit
Transmit Mode
Maintenance Mode
[ MAINTENANCE MENU ]
Quit DIP-SW Status
PT Setting
I/O Check
Init. Memory
Memory Switch
Select “Init. Memory”.
88
Initializing Memory
[ INITIALIZE MEMORY MENU ]
Quit
Init. Screen
Section 3-4
Select “Init. Screen”.
Initialize Screen Memory?
Yes
No
Select “Yes”.
The screen data memory is initialized. During the initialization, the “Initializing” message will be displayed.
If “No” is selected, the memory initialization will be canceled and the NT20 returns to the “operation mode”.
No direct information is set!
Use the Support Tool to set the PT Control Area and PT Notify Area
Example:
Direct information is also initialized. Set the direct information with the Support
Tool.
After initialization of the screen data memory, the system enters the operation mode. At this point, nothing is displayed on the screen of the NT20. Return to the System Menu, select the Transmit Mode, and transmit the screen data from the Support Tool.
If the screen data cannot be initialized for any reason, the message “An Error
Occur Initializing Memory” is displayed.
89
Initializing Memory
Section 3-4
3-4-2 Initialization by Using the DIP Switch (Forced Initialization)
Note
Be sure to turn the power OFF before setting the NT20 DIP switch.
Set the DIP switch as follows to initialize the screen data memory.
1,2,3...
1.
Set DIP SW2-1 on the NT20 to ON and turn the power ON or reset the
NT20.
Initialize Screen Memory?
Yes
Select “Yes”.
The screen data memory is initialized. During the initialization, the “Initializing” message will be displayed.
No
Initialized the
Screen Data Memory.
Turn OFF the DIP Switch 2-1 and push the Reset Switch, then return to RUN mode.
Note
2.
Turn the NT20 power to OFF.
3.
Set NT20 DIP SW2-1 to OFF and turn the power ON.
(1) Selecting “No” will cancel the memory initialization. In either case, when changing the system settings or registering screen data, display the system menu after setting DIP switch SW2-1 to the OFF position while the
NT20 power is OFF, then switching the power back ON.
(2) The NT20 DIP SW2-1 is used to set “Screen data forced initialize Yes/
No”. Setting this to Yes selects “effective”, and No “ineffective”.
90
Pobierz
Reklama