Outline of Functions
Section 4-2
4-2 Outline of Functions
4-2-1 NT20 Screen
This section gives the outline of the screen which is the basis of all NT20 functions.
For specific operation procedure such as screen switching, refer to 5-1-4
Switching the Screen Display (page 172).
Composition of the Screen
The NT20 screen is composed of horizontal 256 dots x vertical 128 dots.
Each dot is set by the combination of the X (horizontal) and Y (vertical) coordinates. The origin of coordinates (0, 0) is set at the top left corner of the screen.
0
X coordinate (horizontal)
0
255
Screen Management
Special Screen Number
Y coordinate
(vertical)
Coordinates
(x, y)
127
255, 127
The screens displayed on the NT20 are managed by the screen numbers.
When using the NT20, up to 495 screens can be created and screen numbers in the ranges 1 to 250 and 256 to 500 can be used (numbers 251 to 255 are reserved for system use).
The display screens can be switched or the start-up screen can be set by designating the screen number from the Host.
Screen number “0” is reserved for the system as the no-display screen. Select this to display nothing on the NT20 screen.
136
Outline of Functions
Section 4-2
4-2-2 Characters and Figures Which Can Be Displayed
The NT20 screen can display characters, figures, and other various elements.
This section describes the types and attributes of the characters and figures which can be displayed and do not need to be changed at all.
For the settings, display, and use of the characters, numeric values, and graphs which change according to the system operation status and other con-
ditions, refer to 4-4 Memory Tables (page 144).
The power of expression of the screen can be increased by giving various attributes such as the enlarged or reverse display to the characters and figures.
The character and figure attributes can be set in the edit screen when creating the screen data by using the Support Tool.
When using the NT20-ST128 (RS-232C), character strings can also be displayed according to commands from the host, independently of the currently displayed screen (this is the “terminal function”).
Types and Attributes of Characters and Figures
The following types of characters can be input by using the Support Tool and be displayed during operation.
Character
Type
Dots
(vertical x horizontal)
8 x 8
Character Set
Half height characters
Normal characters
16 x 8
16 x 16
Alphanumerics and symbols
Alphanumerics and symbols
GB2312
Maximum Number of
Characters Displayed in One
Screen (without overwriting)
32 characters x 16 lines
(512 characters)
32 characters x 8 lines
(256 characters)
16 characters x 8 lines
(128 characters)
Marks 16 x 16 Create by using the
Support Tool
• Marks
A mark is a graphic pattern created by combining 16 x 16 dots by using the
Support Tool. Marks can be handled the same as the wide size characters.
Up to 64 patterns can be defined within the total screen data using character code FF20 to FF5F.
• Enlarged Display of Characters and Marks
The characters and marks can be enlarged to the following scales.
Note
PT PT
PT PT
PT
PT x16 scale x1 scale Double width scale
Double height scale x4 scale x9 scale
Smoothing
The characters and marks enlarged to the x4 scale or larger are displayed with the outline automatically smoothed. This function is called “smoothing”.
137
Outline of Functions
Section 4-2
• Reverse and Flashing Display
Reverse display: The display brightness of the character and the background is reversed comparing with the normal display.
Flashing display: Characters are displayed as they flash. The normal display alternates with no-display.
Reverse and flashing display: The reverse display alternates with the normal display.
Types and Attributes of the Figures
The following types of figures can be input by using the Support Tool and be displayed during operation. Continuous straight lines including up to 256 vertices can be drawn (up to 255 straight lines can be connected).
Continuous straight lines
Circle
4-2-3 Communications with the Host
Communications Using Host Link/NT Link/C200H Direct Communications
The NT20 can communicate with the PLC through the host link/NT link. Bits and words are allocated to areas of the PLC memory (selectable without restriction) and the NT20 can write data to them or read from them directly.
This makes the following functions possible:
• Control/Notification of display elements
• Control/Notification of the NT20 status
• Screen switching
• Ascertaining the number of the screen currently displayed
• Memory table operations
For details on actual operations, refer to SECTION 5 How to Use the Host
Link/NT Link.
Communications through
RS-232C
The NT20-ST128 can communicate with the host through the RS-232C interface. In other words, it can receive and send commands through the RS-232C interface, which allows various types of host to utilize the functions of the
NT20:
• Control/notification of display elements
• Control/notification of the NT20 status
• Memory table operations
• Screen operation
• Display/deletion of characters/graphics
For details on actual operations, refer to SECTION 6 Using RS-232C Commu-
nications.
Controllable NT20 Functions
The following NT20 status can be controlled:
• Screen switching: Screen is displayed or cleared.
• Continuous/intermittent buzzer: Buzzer operation is started or stopped.
• Back light mode: Back light is lit or made to flash.
For details on how these NT20 functions are actually controlled, refer to 5-4
NT20 Status Control on page 203, and Buzzer Control on page 228.
138
Outline of Functions
Section 4-2
Ascertainable Operating Status of the NT20
The following operating status of the NT20 can be ascertained:
• NT20 operating/stopped status: Whether the NT20 is active or inactive
• Screen number: Number of the screen currently displayed
• Numeral setting input: Whether or not numerical values have been input by numeral setting
For details on how these NT20 operating status is actually detected, refer to
5-5 Notification of the Operating Status to the PLC (Determining the NT20
Operating Status) on page 208, Screen Number Response on page 217, and
Eight-digit Number Input Notify on page 225.
!Caution To ensure system safety, be sure to periodically read the PT operating status bit from the host in order to ensure that the PT is always operating normally.
139