Various System Settings
Section 3-8
3-8 Various System Settings
The NT20 can set a variety of functions to the memory switches which are convenient during the operation. This section describes the memory switch settings related to the operation environment.
3-8-1 Setting the Key Press Sound
Whether or not the key press sound is given when the NT20 touch switch is pressed can be set with the memory switch.
The factory setting has been set to give the key press sound when the touch key is pressed.
Set the key press sound by the menu operation from the System Menu as described below.
Select “Maintenance Mode”.
[ SYSTEM MENU ]
Quit
Transmit Mode
Maintenance Mode
[ MAINTENANCE MENU ]
Quit DIP-SW Status
PT Setting
I/O Check
Init. Memory
Memory Switch
Select “Memory Switch”.
[ MEMORY SW MENU ]
(1/2)
Comm. Type
Host Link
Key Sound
OFF
Buzzer Sound
OFF
Bk light Off
None
Tool Mode
NT20S
Quit
Page
WRT
&
EXIT
Each time the “Key Sound” touch switch is pressed, the setting option “ON” alternates with “OFF”.
106
Various System Settings
Section 3-8
To set and quit the menu, press the [WRT & EXIT] touch switch. To quit without setting, press [Quit].
• ON: The key press sound will be given for 0.2 second when a touch switch is pressed.
• OFF: The key press sound will not be given when a touch key is pressed.
3-8-2 Using the Buzzer
The NT20 can set a buzzer to indicate the occurrence of an emergency or an
NT20 error.
Setting the Buzzer
Stopping the Buzzer
Note
Note
Except when the buzzer has been set so as not to sound at all, the buzzer will sound when an error occurs. To set the buzzer to sound in other cases, the following two procedures can be used.
• Controlled by the Host
It is possible to control the NT20 from the Host to sound the buzzer during the operation.
Refer to 5-4 NT20 Status Control on page 203.
• Set the buzzer as a screen data attribute by using the Support Tool.
When creating the screen data by using the Support Tool, set the buzzer as a screen attribute so that the buzzer will sound. When the screen in which this attribute has been set is displayed, the NT20 will give the buzzer sound.
If the control by the Host and the display of the screen in which the buzzer attribute has been set are executed simultaneously, the priority is given to the control by the Host. Refer to the NT Support Tool for Windows Operation Manual (Cat . No.V061-E1@).
The buzzer sound can be stopped by the following operation.
• Control by the Host
• Switch the screen to a screen which does not have a buzzer attribute.
• Press the touch switch to which the buzzer stop attribute has been set.
If a buzzer stop attribute has been set to a touch switch created on the screen in which the buzzer attribute has been set, such touch switch can be used to stop the buzzer sound. For details on setting buzzer attributes for touch
switches, see Allocation of System Key Functions on page 154.
107
Various System Settings
Types of Buzzer Sounds
Setting the Buzzer
Section 3-8
Note
The following buzzer sounds can be set.
• Continuous sound: The buzzer continues to sound.
• Intermittent sound: The buzzer sounds intermittently at constant intervals.
If both the continuous buzzer and the intermittent buzzer are instructed by the
Host, the continuous buzzer will sound.
Use the memory switches to set whether or not the buzzer sounds when the buzzer sound has been instructed by the Host or with a screen attribute or when an error has occurred.
The factory setting is “ON”, which means that the buzzer will sound when a command is received from the host, when a screen for which the buzzer attribute is set is displayed, and when errors occur.
Set the buzzer sound by the menu operation from the System Menu as described below.
Select “Maintenance Mode”.
[ SYSTEM MENU ]
Quit
Transmit Mode
Maintenance Mode
[ MAINTENANCE MENU ]
Quit DIP-SW Status
PT Setting
I/O Check
Init. Memory
Memory Switch
Select “Memory Switch”.
[ MEMORY SW MENU ]
(1/2)
Comm. Type
Host Link
Key Sound
OFF
Buzzer Sound
OFF
Quit
Page
Bk light Off
Tool Mode
None
NT20S
WRT
&
EXIT
Repeatedly pressing the
“Buzzer Sound” touch switch cycles through the setting options “ON”, “ERR ON”, and
“OFF”, in that order.
108
Various System Settings
Section 3-8
Note
To set and quit the menu, press the [WRT&EXIT] touch switch. To quit without setting, press [Quit].
• OFF: The buzzer will not sound at all during the operation.
• When “ON” is set, the buzzer will sound when a command is received from the host, when a screen for which the buzzer attribute is set is displayed, and when errors occur.
• When “ERR ON” has been set, the buzzer will sound only when an error has occurred.
The buzzer will sound when “Buzzer check” is selected in the Maintenance
Mode regardless of the buzzer setting.
3-8-3 Backlight OFF Function
The NT20 has a function that turns off the backlight of the LCD panel to maximize its service life if no operation is performed for a certain period of time.
Turning ON the Backlight
When a touch switch on the NT20 is pressed or a screen is switched or redisplayed by the PLC when the backlight is off by the backlight off function, the backlight will turn on. Any changes of numeric values or characters displayed on the screen will not effect the backlight to turn on again.
Setting the Backlight OFF Function
Use the memory switches to set whether or not the backlight off function is used and the length of time to turn off the backlight.
The factory setting has been made so as to turn off the backlight if no operation has been performed for 10 minutes.
Set the backlight off function by the menu operation from the System Menu as described below.
Select “Maintenance Mode”.
[ SYSTEM MENU ]
Quit
Transmit Mode
Maintenance Mode
[ MAINTENANCE MENU ]
Quit DIP-SW Status
PT Setting
I/O Check
Init. Memory
Memory Switch
Select “Memory Switch”.
109
Various System Settings
Section 3-8
[ MEMORY SW MENU ]
(1/2)
Comm. Type
Host Link
Key Sound
OFF
Buzzer Sound
OFF
Quit
Page
Bk light Off
Tool Mode
None
NT20S
WRT
&
EXIT
Repeatedly pressing the
“BK light Off” touch switch cycles through the setting options “10 min”, 1 hour, and None, in that order.
To set and quit the menu, press the [WRT&EXIT] touch switch. To quit without setting, press [Quit].
• None: The backlight off function is not used. As long as no operation is performed, the same screen remains to be displayed.
• 10 minutes: The backlight will be turned off when no operation has been performed for 10 minutes.
• 1 hour: The backlight will be turned off when no operation has been performed for 1 hour.
!Caution Do not press touch switches carelessly while the backlight is off or while nothing is displayed on the screen.
Otherwise the system may operate unpredictably.
Only press touch switches after confirming system safety.
Note
Continuous display of the same pattern for an extended time (as a guide, about 1 hour) will lead to the formation of an afterimage.
In order to prevent this, either use the screen saver function or periodically switch screens.
3-8-4 Language Function
The language selection items will be different according to the DIP-SW2-2.
When DIP-SW2-2 is pushed to ON, the language is fixed to English. That is, user can't choose other language but English.
When DIP-SW2-2 is pushed to OFF, the languages can be switched in this language item in Memory SW Menu. Both Japanese and English are available.
DIP-SW2-2 is ON.
(Host link) (NT Link (1:1))
[ MEMORY SW MENU ]
(2/2)
Automatic Reset
No
Baud Rate
Comm. Port
9600bps
Port B
Quit
Page
Language English
WRT
&
EXIT
[ MEMORY SW MENU ]
(2/2)
Automatic Reset No
Comm. Port
Port B
Language
English
Quit
Page
WRT
&
EXIT
110
Various System Settings
Section 3-8
(NT Link (1:N))
[ MEMORY SW MENU ]
(2/2)
Automatic Reset
No
Unit No.
Comm. Speed
7
Standard
Quit
Page
Comm. Port
Language
Port B
English
WRT
&
EXIT
DIP-SW2-2 is OFF.
(Host link) (NT Link (1:1))
[ MEMORY SW MENU ]
(2/2)
Automatic Reset
No
Baud Rate
Comm. Port
9600bps
Port B
Quit
Page
Language
English
WRT
&
EXIT
(NT Link (1:N))
[ MEMORY SW MENU ]
(2/2)
Automatic Reset
No
Unit No.
Comm. Speed
Comm. Port
Language
7
Standard
Port B
English
Quit
Page
WRT
&
EXIT
[ MEMORY SW MENU ]
(2/2)
Automatic Reset No
Comm. Port
Port B
Language
English
Quit
Page
WRT
&
EXIT
3-8-5 Support Tool Mode Setting (NT20-ST121-E)
By setting “Tool Mode” to “NT20M”, the NT20 can be used in the same way as the conventional NT20M/NT20S, and it becomes possible to use the NT
Series Support Tool (version 2.
@).
However, the following restrictions apply when “NT20M” is set:
• Version 5 of the direct connection function cannot be used.
• The PT type setting must be “NT20M”.
• High-speed data transfer with the Support Tool is not possible.
• It is not possible to transfer the direct information alone.
• When screen data transmission is in screen units, simultaneous transmission of multiple screens is not possible. An attempt to transmit multiple screens may destroy the screen data.
• When screen data transmission is in screen units, transmission with verification set is not possible.
• The image data memory must be initialized before starting transfer in file units.
• Screen data for RS-232C communications cannot be used.
111
Various System Settings
Section 3-8
Set the Support Tool mode by the menu operation from the system menu shown below.
Select “Maintenance Mode”.
[ SYSTEM MENU ]
Quit
Transmit Mode
Maintenance Mode
[ MAINTENANCE MENU ]
Quit DIP-SW Status
PT Setting
I/O Check
Init. Memory
Memory Switch
Select “Memory Switch”.
[ MEMORY SW MENU ]
(1/2)
Comm. Type
Host Link
Key Sound
OFF
Buzzer Sound
OFF
Bk light Off
None
Tool Mode
NT20S
Quit
Page
WRT
&
EXIT
Each time the “Tool Mode” touch switch is pressed, the setting option alternates between “NT20”, “NT20S”, and “NT20M”.
(The figure to the left shows the NT20-ST121 @-E screen.)
To quit after setting the selected item, press the WRT & EXIT touch switch. To quit without setting, press the Quit touch switch. The NT20 will enter the RUN mode.
• When “NT20M” or “NT20S” is set, the NT20M/NT20S compatible mode is established and the terminal can be used as an NT20M/NT20S.
• When “NT20” is set, the terminal can be used as an NT20.
Note
Before uploading screen data from the NT20 to the Support Tool, confirm that the model information for the screen data in the NT20 and the Tool's transfer mode match. If they do not match, the upload may fail or data may change, preventing correct operation.
3-8-6 Lamp Bit Control (NT20-ST128)
When using the NT20-ST128 (using the RS-232C interface for communications with the host), you can select whether lamp status is controlled by bit designation or not.
The factory setting for this function is “Enable” (lamps numbered 0 to 31 controlled by bits).
112
Various System Settings
Section 3-8
Set the lamp bit control function by the menu operation from the System Menu as described below.
Select “Maintenance Mode”.
[ SYSTEM MENU ]
Quit
Transmit Mode
Maintenance Mode
[ MAINTENANCE MENU ]
Quit DIP-SW Status
PT Setting
I/O Check
Init. Memory
Memory Switch
Select “Memory Switch”.
[MEMORY SW MENU]
(1/3)
Key Sound
ON
Buzzer Sound
ON
Bk light Off
10 min
Quit
Page
Tool Mode
Automatic Reset
NT20S
Yes
WRT
&
EXIT
Select “Page down”.
[MEMORY SW MENU]
(2/3)
Data Bits
8 bits
Stop Bits
1 bit
Parity Check
Even
Flow Control
RS/CS
Baud Rate
19200 ps
Quit
Page
WRT
&
EXIT
Select “Page down”.
113
Various System Settings
Section 3-8
[MEMORY SW MENU]
(3/3)
LMP Bit Control
Enable
Comm. Port
Port B
Language
English
Quit
Page
WRT
&
EXIT
Each time the “LMP Bit Control” touch switch is pressed, the setting option “Enable” alternates with “Disable”.
To set and quit the menu, press the [WRT&EXIT] touch switch. To quit without setting, press [Quit].
• When “Disable” is set, the control of lamp display status by bits is not possible. The lamps numbered 0 to 31 can be controlled only by specifying lamp numbers.
• When “Enable” is set, lamp control by bits is possible. This means that the lamps numbered 0 to 31 can be controlled by specifying either lamp numbers or bits. However, it is not possible to make “lit”/”flashing” status selections by specifying lamp numbers: the selection made when the screen data was created remains effective.
114