Touch Switches
Section 4-7
4-7 Touch Switches
The NT20 has a function whereby input operations can be performed by using touch panels displayed on the screen. NT20 screens can be switched, or bit information sent to the Host, by pressing (lightly touching) the “touch switches” in a panel.
The touch switches can also be made to light up (or flash) and go off like lamps.
Touch switches are set when creating the screen data with the Support Tool.
This section describes the touch switches that can be displayed, and explains the screen switching function and the system key function.
For details on how the status of the currently displayed touch switch is sent to
the Host, refer to 5-3-4 Lit (Flashing) and Unlit Touch Switch Status (Changing
the Status of Allocated Bits) on page 195, Lamp and Touch Switch Display
(Bit Specification) on page 223, and Lamp and Touch Switch Display (Number
Specification) on page 223.
For details on how the status of touch switches is ascertained by the Host,
refer to 5-3-5 Notifying the Host That a Switch Has Been Pressed (Determin-
ing Touch Switch Status) on page 196, and Lamp and Touch Switch Display
Status Enquiry on page 224.
!Caution Do not use input functions such as PT touch switches for applications where danger to human life or serious property damage is possible or for emergency switch applications.
!Caution Press touch switches with a force of no greater than 30 N.
!Caution Do not press touch switches carelessly while the backlight is off or while nothing is displayed on the screen. Otherwise the system may operate unpredictably.
Only press touch switches after confirming system safety.
!Caution If touch switches are pressed in rapid succession, their inputs may not be successfully received.
Confirm that the input of a touch switch has been successfully received before moving on to the next operation.
Note
Caution on pressing touch switches at 3 points
When multiple touch switches are created at the relative positions indicated in the example below, malfunctions may occur due to the characteristics of this switch configuration.
Example 1: When switches are created at positions A and B and at the points where the vertical and horizontal lines extending from these two points intersect, i.e. points C and D:
A
C
• When switches A, B, and C are switched on at the same time, switch D is also assumed to have been switched on due to the configuration of the touch switches.
B
D
Smallest touch switch frame
• When switches A, B, and D are switched on at the same time, switch C is also assumed to have been switched on due to the configuration of the touch switches.
152
Touch Switches
Section 4-7
4-7-1 Functions of Touch Switches
Touch switches are created using rectangular elements measuring 19 dots horizontally by 19 dots vertically. A touch switch can comprise more than one touch switch element. Up to 72 touch switches (12 horizontally x 6 vertically) can be registered on one screen.
19 dots
19 dots
Touch Switch Attributes
PLC
When the touch switch is pressed, bit information is sent to the PLC.
(Host link/NT link)
A touch switch can comprise more than one touch switch element.
Host
When the touch switch is pressed, the touch switch number or bit information is sent to the Host (RS-232C).
• Functions of Touch Switches
Touch switches can have the following functions:
• PLC notification function:
Host link/NT link/C200H direct communications (page 196)
RS-232C (NT20-ST128) (page 224)
• Screen switch function (page 154)
• System key function (page 154)
• Numeral setting function:
Host link/NT link/C200H direct communications (page 199)
RS-232C (NT20-ST128) (page 224)
The following attributes can be set for touch switches.
• Display Frame
The area that will respond as a touch switch is displayed in the form of a frame, as shown in the table below. One of three types of frame - standard,
3-D, and none - can be selected.
Type of Display Frame
Standard
Switch OFF Switch ON
3-D
None
If “none” is selected, only the touch switch’s guide display message (or nothing, if there is none) are displayed until a “light” or “flash” designation is sent from the PLC/Host or the touch switch is pressed.
• Inverse Display on Input
It is possible to set a touch switch so that its display will be inverted when it is pressed.
• Lighting and Flashing
153
Touch Switches
Section 4-7
It is possible to specify whether the touch switch will be lit continuously or flash when the bit allocated to it is turned ON by the PLC/Host.
• Presence/Absence of a Guide Display
A guide display message can be displayed at a touch switch location.
4-7-2 Screen Switching Function
The NT20 has a function that allows screens to be switched by pressing touch switches on its screen, rather than by designation from the PLC/Host. This function is called the “standalone function”.
The screen number of the screen that will be displayed when a touch switch is pressed is set for that touch switch when the screen data is created using the
Support Tool.
If the touch switch is pressed during operation, the screen whose number was designated will be displayed. Simultaneously, the PLC/Host will be notified of the screen number of the screen selected for display.
To next screen
Touch switch pressed once
Screen #5
Note
"Screen #5" set for touch switch 1
To set a screen number for a touch switch, use “Touch SW”, “Bit specification” and “Screen switch” of the Support Tool.
Only one screen number can be set for one touch switch within one screen (or within one overlapping screen).
4-7-3 System Key Functions
The NT20 allows the allocation of “system key” functions to touch switches.
The system key functions can then be used during operation by pressing the touch switches to which they have been allocated.
For example, if, when a screen for which buzzer sounding has been set is displayed, a touch switch is also displayed, the buzzer can be stopped by pressing this touch switch.
To set a system key function for a touch switch, use “Touch SW”, “Bit specification” and “Numeric key” of the Support Tool.
Allocation of System Key
Functions
The system key functions are allocated to touch switch numbers 227 to 230 and 255, as shown below. When a touch switch with one of these numbers is displayed on the screen, it has the same function as the corresponding system key.
System Key
System menu display
Key Symbol
MENU
227
Touch Switch No.
228
229
[Buzzer stop]
[ENT]
230
255
154
Touch Switches
Section 4-7
➡
When a touch switch to which a system key function has been allocated is pressed, the PLC is not notified of the touch switch bit information.
The , , and keys are not displayed among the system numeric keys.
Accordingly, when using the system numeric keys, create the , , and keys. Alternatively, create user numeric keys.
155